CC-Link IE Field Network, Block Type Remote Unit NZ2GF Series (NZ2GF2B2-16S)

CC-Link IE Field Network, Block Type Remote Unit NZ2GF Series NZ2GF2B2-16S

[CC-Link IE Field Network, Block Type Remote Unit]
・ CC-Link IE field network remote device station. Input/output devices can be more easily distributed according to the equipment
・ You can easily add the number of input/output points by connecting expansion units
・ It supports CC-Link IE field network synchronous communication function. Since the operation can be performed according to the synchronization cycle of the master station that supports the synchronous communication function, the operation timings of multiple slave stations can be aligned
・ Units that support the fast link-up function can quickly return to the line when the CC-Link IE field network is disconnected and then reconnected
・ Units that support the automatic I/O parameter setting function can operate the input/output unit without setting parameters, so the startup time can be shortened

(i)Caution

  • The product images are representative only. Please refer to the manufacturer's catalog for shape details.

Part Number

Configured Part Number is shown.

NZ2GF2B2-16S

Part Number
NZ2GF2B2-16S
Part NumberStandard Unit PriceMinimum order quantityVolume DiscountDays to ShipNumber Of Inputs Input Format Rated Input Voltage
(V)
Input answer time Number of Outputs Output Format Rated load voltage
(V)
Protection function Connection Terminal Representative Standard Features Rated input current
(mA)
Max Load Current Terminal shape Type of unit External connection Input format details Wiring Int. Current Consumption
(A)

-

1 Piece(s) Quote ----16Triac output100 to 240 ACNoneTerminal Block-Number of expansion units that can be connected: 1-0.6AScrewBasic output unit2-wire type---

Loading...

  1. 1

Please check the type/dimensions/specifications of the part NZ2GF2B2-16S in the CC-Link IE Field Network, Block Type Remote Unit NZ2GF Series series.

Similar Part Numbers

Part Number
NZ2GF2B1-32T
NZ2GF2B1N1-16D
NZ2GF2B1N1-16T
NZ2GF2S2-16S
NZ2GFCE3-16DE
NZ2GFCF1-32D
Part NumberStandard Unit PriceMinimum order quantityVolume DiscountDays to ShipNumber Of Inputs Input Format Rated Input Voltage
(V)
Input answer time Number of Outputs Output Format Rated load voltage
(V)
Protection function Connection Terminal Representative Standard Features Rated input current
(mA)
Max Load Current Terminal shape Type of unit External connection Input format details Wiring Int. Current Consumption
(A)

SGD 500.00

1 Piece(s) Quote -DC input---Transistor / sync output12/24--CE / CUL / UL-------Screw0,13

-

1 Piece(s) Quote 16DC input24Less than 50 to 100 mS---NoneTerminal Block-Number of expansion units that can be connected: 36-Spring clampBasic input unit1-wire typePositive common / negative common--

-

1 Piece(s) Quote ----16Transistor / sync output12/24NoneTerminal Block-Number of expansion units that can be connected: 3-0.5AScrewBasic output unit1-wire type---

-

1 Piece(s) Quote ----16Triac output100 to 240 ACNoneTerminal Block-Number of expansion units that can be connected: 1-0.6ASpring clampBasic output unit2-wire type---

-

1 Piece(s) Quote 16DC input24Less than 50 to 100 mS---NoneConnector-Number of expansion units that can be connected: 14-Sensor connector (e-CON)Basic input unit3-wire typeNegative Common--

-

1 Piece(s) Quote 32DC input24Less than 50 to 100 mS---NoneConnector-Number of expansion units that can be connected: 14-40 pinsBasic input unit1-wire typePositive common / negative common--