(!)Due to Microsoft's end of support for Internet Explorer 11 on 15/06/2022, this site does not support the recommended environment.
Instead, please kindly use other browsers like Google Chrome, Microsoft Edge or Mozilla Firefox.

  • Scheduled Maintenance Notice: This site will be unavailable due to scheduled maintenance from 9:00 24/11/2024 to 7:00 (SGT) 25/11/2024. We apologize for the inconvenience.
  • Notice of End of Sales for Economy Series Pneumatic Equipment Category. More information.

CC-Link IE Field Network, Block Type Remote Unit NZ2GF Series (NZ2GFCE3-16DE)

CC-Link IE Field Network, Block Type Remote Unit NZ2GF Series NZ2GFCE3-16DE

[CC-Link IE Field Network, Block Type Remote Unit]
・ CC-Link IE field network remote device station. Input/output devices can be more easily distributed according to the equipment
・ You can easily add the number of input/output points by connecting expansion units
・ It supports CC-Link IE field network synchronous communication function. Since the operation can be performed according to the synchronization cycle of the master station that supports the synchronous communication function, the operation timings of multiple slave stations can be aligned
・ Units that support the fast link-up function can quickly return to the line when the CC-Link IE field network is disconnected and then reconnected
・ Units that support the automatic I/O parameter setting function can operate the input/output unit without setting parameters, so the startup time can be shortened

(i)Caution

  • The product images are representative only. Please refer to the manufacturer's catalog for shape details.

Part Number

Configured Part Number is shown.

NZ2GFCE3-16DE

Part Number
NZ2GFCE3-16DE
Part NumberStandard Unit PriceMinimum order quantityVolume DiscountDays to ShipNumber Of Inputs Input Format Rated Input Voltage
(V)
Input answer time Number of Outputs Output Format Rated load voltage
(V)
Protection function Connection Terminal Representative Standard Features Rated input current
(mA)
Max Load Current Terminal shape Type of unit External connection Input format details Wiring Int. Current Consumption
(A)

-

1 Piece(s) Quote 16DC input24Less than 50 to 100 mS---NoneConnector-Number of expansion units that can be connected: 14-Sensor connector (e-CON)Basic input unit3-wire typeNegative Common--

Loading...

  1. 1

Please check the type/dimensions/specifications of the part NZ2GFCE3-16DE in the CC-Link IE Field Network, Block Type Remote Unit NZ2GF Series series.

Similar Part Numbers

Part Number
NZ2GF2B1-32DTE
NZ2GF2B1-32T
NZ2GF2B1N1-16D
NZ2GF2B1N1-16T
NZ2GFCF1-32D
NZ2GFCF1-32T
Part NumberStandard Unit PriceMinimum order quantityVolume DiscountDays to ShipNumber Of Inputs Input Format Rated Input Voltage
(V)
Input answer time Number of Outputs Output Format Rated load voltage
(V)
Protection function Connection Terminal Representative Standard Features Rated input current
(mA)
Max Load Current Terminal shape Type of unit External connection Input format details Wiring Int. Current Consumption
(A)

-

1 Piece(s) Quote -DC input---Transistor / source output24--CE / CUL / UL-------Screw0,12

SGD 500.00

1 Piece(s) Quote -DC input---Transistor / sync output12/24--CE / CUL / UL-------Screw0,13

-

1 Piece(s) Quote 16DC input24Less than 50 to 100 mS---NoneTerminal Block-Number of expansion units that can be connected: 36-Spring clampBasic input unit1-wire typePositive common / negative common--

-

1 Piece(s) Quote ----16Transistor / sync output12/24NoneTerminal Block-Number of expansion units that can be connected: 3-0.5AScrewBasic output unit1-wire type---

-

1 Piece(s) Quote 32DC input24Less than 50 to 100 mS---NoneConnector-Number of expansion units that can be connected: 14-40 pinsBasic input unit1-wire typePositive common / negative common--

-

1 Piece(s) Quote ----32Transistor / sync output12/24NoneConnector-Number of expansion units that can be connected: 1-0.1A40 pinsBasic output unit1-wire type---

Tech Support