(!)Due to Microsoft's end of support for Internet Explorer 11 on 15/06/2022, this site does not support the recommended environment.
Instead, please kindly use other browsers like Google Chrome, Microsoft Edge or Mozilla Firefox.
A wide variety of standard and configurable components for factory automation engineers in industries such as automotive, semiconductor, packaging, medical and many more.
A good selection of accessories such as screws, bolts, washers and nuts that you may need for your daily engineering usage.
Browse industrial materials ranging from heat insulating plates, sponges, to metal and plastic materials in different sizes to meet your various applications.
A wide variety of wiring parts for connecting and protecting control and PC parts including Connectors, Cables, Electric Wires, Crimping Terminals and more.
A wide variety of controls and PC parts for electrical engineers including Controls, Powers, PC parts and more.
A wide variety of cutting tools for many uses and work materials including End Mills, Drills, Cutters, Reamers, Turning Tools and more.
A wide variety of tools and supplies used in processing including Machine Tools, Measurement Tools, Grinding and Polishing Supplies and more.
A wide variety of goods used in shipment, material handling and warehouse including Tape supplies, Stretch film, Truck, Shelf, Crane and more.
A large variety of goods for every kind of factories and offices including Protection items, Cleaning supplies, sanitations, office supplies and more.
A large variety of items used in R&D and Clean Room including research Equipment, Laboratory Essentials, Analysis Supplies, Clean Environment-Related Equipment and more.
Choose from thousands of standard stamping die components including Punch & Die, Gas Springs, Guide Components, Coil Springs and many more.
Browse our wide variety of mold components including Ejector Pins, Sleeves, Leader Components, Sprue Bushings and many more.
Browse our injection molding components including Heating Items, Couplers, Hoses and more.
Power supply unit for iQ-R series available.
Part Number
Configured Part Number is shown.
R64RP
R61P external appearance
R61P dimensional outline drawing
(Unit: mm)
Input Power Supply Voltage | 100 to 240 V AC (85 to 264 V AC) | ||
---|---|---|---|
Input Frequency | 50/60 Hz ±5% | ||
Input Voltage Strain Factor | Within 5% | ||
Input Maximum Apparent Power | 130 VA | ||
Inrush Current | 20 A within 8 ms | ||
Rated Output Current | 5 V DC | 6.5 A | |
Excess Current Protection | 5 V DC | 7.1 A or more | |
Excess Voltage Protection | 5 V DC | 5.5 to 6.5 V | |
Efficiency | 76% or more | ||
Allowable Momentary Power Loss Duration | Within 20 ms | ||
Withstand Voltage | 2,300 Vrms AC / 1 minute (altitude 0 to 2,000 m) between all inputs / LG at once and all outputs / FG at once | ||
Insulation Resistance | Between all inputs / LG at once and all outputs / FG at once, between all inputs at once and LG, between all outputs at once and FG: 10 MΩ or more at 500 V DC on an insulation resistance meter | ||
Fuse | Built-in (cannot be replaced by the user) | ||
Contact Output Part | Applications | ERR Contact | |
Rated Switching Voltage/Current | 24 V DC, 0.5 A | ||
Minimum Switching Load | 5 V DC 1 mA | ||
Response Time | OFF→ON | 10 ms or less | |
ON→OFF | 12 ms or less | ||
Lifespan | Mechanical | 20,000,000 operations or more | |
Electrical | Rated switching voltage/current 100,000 times or more | ||
Surge Protector | No | ||
Fuse | No | ||
External Dimensions | Height (H) | 106 mm (98 mm at the base unit mounting part) | |
Width (W) | 54.6 mm | ||
Depth (D) | 110 mm | ||
Mass | 0.41 kg |
(Unit: mm)
R62P/R63P/R64P dimensional outline drawing
Input Power Supply Voltage | 100 to 240 V AC (85 to 264 V AC) | ||
---|---|---|---|
Input Frequency | 50/60 Hz ±5% | ||
Input Voltage Strain Factor | Within 5% | ||
Input Maximum Apparent Power | 120 VA | ||
Inrush Current | 20 A within 8 ms | ||
Rated Output Current | 5 V DC | 3.5 A | |
24 V DC | 0.6 A | ||
Excess Current Protection | 5 V DC | 3.8 A or more | |
24 V DC | 0.66 A or more | ||
Excess Voltage Protection | 5 V DC | 5.5 to 6.5 V | |
Efficiency | 76% or more | ||
Allowable Momentary Power Loss Duration | Within 20 ms | ||
Withstand Voltage | 2,300 Vrms AC / 1 minute (altitude 0 to 2,000 m) between all inputs / LG at once and all outputs / FG at once | ||
Insulation Resistance | Between all inputs / LG at once and all outputs / FG at once, between all inputs at once and LG, between all outputs at once and FG: 10 MΩ or more at 500 V DC on an insulation resistance meter | ||
Fuse | Built-in (cannot be replaced by the user) | ||
Contact Output Part | Applications | ERR Contact | |
Rated Switching Voltage/Current | 24 V DC, 0.5 A | ||
Minimum Switching Load | 5 V DC 1 mA | ||
Response Time | OFF→ON | 10 ms or less | |
ON→OFF | 12 ms or less | ||
Lifespan | Mechanical | 20,000,000 operations or more | |
Electrical | Rated switching voltage/current 100,000 times or more | ||
Surge Protector | No | ||
Fuse | No | ||
External Dimensions | Height (H) | 106 mm (98 mm at the base unit mounting part) | |
Width (W) | 54.6 mm | ||
Depth (D) | 110 mm | ||
Mass | 0.45 kg |
Input Power Supply Voltage | 24 V DC (15.6 to 31.2 V DC) | ||
---|---|---|---|
Input Maximum Power | 50 W | ||
Inrush Current | 100 A within 1 ms | ||
Rated Output Current | 5 V DC | 6.5 A | |
Excess Current Protection | 5 V DC | 7.1 A or more | |
Excess Voltage Protection | 5 V DC | 5.5 to 6.5 V | |
Efficiency | 70% or more | ||
Allowable Momentary Power Loss Duration | Within 10 ms | ||
Withstand Voltage | 50 V AC / 1 minute (altitude 0 to 2,000 m) Between primary side and 5 V DC | ||
Insulation Resistance | Between all inputs / LG at once and all outputs / FG at once, between all inputs at once and LG, between all outputs at once and FG: 10 MΩ or more at 500 V DC on an insulation resistance meter | ||
Fuse | Built-in (cannot be replaced by the user) | ||
Contact Output Part | Applications | ERR Contact | |
Rated Switching Voltage/Current | 24 V DC, 0.5 A | ||
Minimum Switching Load | 5 V DC 1 mA | ||
Response Time | OFF→ON | 10 ms or less | |
ON→OFF | 12 ms or less | ||
Lifespan | Mechanical | 20,000,000 operations or more | |
Electrical | Rated switching voltage/current 100,000 times or more | ||
Surge Protector | No | ||
Fuse | No | ||
External Dimensions | Height (H) | 106 mm (98 mm at the base unit mounting part) | |
Width (W) | 54.6 mm | ||
Depth (D) | 110 mm | ||
Mass | 0.41 kg |
Input Power Supply Voltage | 100 to 240 V AC (85 to 264 V AC) | ||
---|---|---|---|
Input Frequency | 50/60 Hz ±5% | ||
Input Voltage Strain Factor | Within 5% | ||
Input Maximum Apparent Power | 160 VA | ||
Inrush Current | 20 A within 8 ms | ||
Rated Output Current | 5 V DC | 9 A | |
Excess Current Protection | 5 V DC | 10.0 A or more | |
Excess Voltage Protection | 5 V DC | 5.5 to 6.5 V | |
Efficiency | 76% or more | ||
Allowable Momentary Power Loss Duration | Within 20 ms | ||
Withstand Voltage | 2,300 Vrms AC / 1 minute (altitude 0 to 2,000 m) between all inputs / LG at once and all outputs / FG at once | ||
Insulation Resistance | Between all inputs / LG at once and all outputs / FG at once, between all inputs at once and LG, between all outputs at once and FG: 10 MΩ or more at 500 V DC on an insulation resistance meter | ||
Fuse | Built-in (cannot be replaced by the user) | ||
Contact Output Part | Applications | ERR Contact | |
Rated Switching Voltage/Current | 24 V DC, 0.5 A | ||
Minimum Switching Load | 5 V DC 1 mA | ||
Response Time | OFF→ON | 10 ms or less | |
ON→OFF | 12 ms or less | ||
Lifespan | Mechanical | 20,000,000 operations or more | |
Electrical | Rated switching voltage/current 100,000 times or more | ||
Surge Protector | No | ||
Fuse | No | ||
External Dimensions | Height (H) | 106 mm (98 mm at the base unit mounting part) | |
Width (W) | 54.6 mm | ||
Depth (D) | 110 mm | ||
Mass | 0.46 kg |
R63RP external appearance
R63RP dimensional outline drawing
(Unit: mm)
Input Power Supply Voltage | 24 V DC (19.2 to 31.2 V DC) | ||
---|---|---|---|
Input Maximum Power | 50 W | ||
Inrush Current | 100 A within 1 ms | ||
Rated Output Current | 5 V DC | 6.5 A | |
Excess Current Protection | 5 V DC | 7.1 A or more | |
Excess Voltage Protection | 5 V DC | 5.5 to 6.5 V | |
Efficiency | 70% or more | ||
Allowable Momentary Power Loss Duration | Within 10 ms | ||
Withstand Voltage | 50 V AC / 1 minute (altitude 0 to 2,000 m) Between primary side and 5 V DC | ||
Insulation Resistance | Between all inputs / LG at once and all outputs / FG at once, between all inputs at once and LG, between all outputs at once and FG: 10 MΩ or more at 500 V DC on an insulation resistance meter | ||
Fuse | Built-in (cannot be replaced by the user) | ||
Contact Output Part | Applications | ERR Contact | |
Rated Switching Voltage/Current | 24 V DC, 0.5 A | ||
Minimum Switching Load | 5 V DC 1 mA | ||
Response Time | OFF→ON | 10 ms or less | |
ON→OFF | 12 ms or less | ||
Lifespan | Mechanical | 20,000,000 operations or more | |
Electrical | Rated switching voltage/current 100,000 times or more | ||
Surge Protector | No | ||
Fuse | No | ||
External Dimensions | Height (H) | 106 mm (98 mm at the base unit mounting part) | |
Width (W) | 54.6 mm | ||
Depth (D) | 110 mm | ||
Mass | 0.41 kg |
R64RP external appearance
R64RP dimensional outline drawing
(Unit: mm)
Input Power Supply Voltage | 100 to 240 V AC (85 to 264 V AC) | ||
---|---|---|---|
Input Frequency | 50/60 Hz ±5% | ||
Input Voltage Strain Factor | Within 5% | ||
Input Maximum Apparent Power | 160 VA | ||
Inrush Current | 20 A within 8 ms | ||
Rated Output Current | 5 V DC | 9 A | |
Excess Current Protection | 5 V DC | 10.0 A or more | |
Excess Voltage Protection | 5 V DC | 5.5 to 6.5 V | |
Efficiency | 76% or more | ||
Allowable Momentary Power Loss Duration | Within 20 ms | ||
Withstand Voltage | 2,300 Vrms AC / 1 minute (altitude 0 to 2,000 m) between all inputs / LG at once and all outputs / FG at once | ||
Insulation Resistance | Between all inputs / LG at once and all outputs / FG at once, between all inputs at once and LG, between all outputs at once and FG: 10 MΩ or more at 500 V DC on an insulation resistance meter | ||
Fuse | Built-in (cannot be replaced by the user) | ||
Contact Output Part | Applications | ERR Contact | |
Rated Switching Voltage/Current | 24 V DC, 0.5 A | ||
Minimum Switching Load | 5 V DC 1 mA | ||
Response Time | OFF→ON | 10 ms or less | |
ON→OFF | 12 ms or less | ||
Lifespan | Mechanical | 20,000,000 operations or more | |
Electrical | Rated switching voltage/current 100,000 times or more | ||
Surge Protector | No | ||
Fuse | No | ||
External Dimensions | Height (H) | 106 mm (98 mm at the base unit mounting part) | |
Width (W) | 54.6 mm | ||
Depth (D) | 110 mm | ||
Mass | 0.46 kg |
Part Number |
---|
R64RP |
Part Number | Standard Unit Price | Minimum order quantity | Volume Discount | Days to Ship |
---|---|---|---|---|
- | 1 Piece(s) | Quote |
Loading...
Please check the type/dimensions/specifications of the part R64RP in the iQ-R Series Power Supply Unit series.
Part Number |
---|
R61P |
R62P |
R63P |
R63RP |
R64P |
Part Number | Standard Unit Price | Minimum order quantity | Volume Discount | Days to Ship |
---|---|---|---|---|
SGD 173.60 | 1 Piece(s) | 20 Day(s) | ||
SGD 201.30 | 1 Piece(s) | 20 Day(s) | ||
SGD 303.70 | 1 Piece(s) | 91 Day(s) | ||
- | 1 Piece(s) | Quote | ||
SGD 303.70 | 1 Piece(s) | 20 Day(s) |
How can we improve?
How can we improve?