(!)Due to Microsoft's end of support for Internet Explorer 11 on 15/06/2022, this site does not support the recommended environment.
Instead, please kindly use other browsers like Google Chrome, Microsoft Edge or Mozilla Firefox.

  • Scheduled Maintenance Notice: This site will be unavailable due to scheduled maintenance from 9:00 24/11/2024 to 7:00 (SGT) 25/11/2024. We apologize for the inconvenience.
  • Notice of End of Sales for Economy Series Pneumatic Equipment Category. More information.

iQ-R Series Power Supply Unit (R64P)

Part Number

Configured Part Number is shown.

R64P

iQ-R Series Power Supply Unit Specifications

R61P external appearance

R61P external appearance

R61P dimensional outline drawing

R61P dimensional outline drawing

 

(Unit: mm)

 

Input Power Supply Voltage100 to 240 V AC (85 to 264 V AC)
Input Frequency50/60 Hz ±5%
Input Voltage Strain FactorWithin 5%
Input Maximum Apparent Power130 VA
Inrush Current20 A within 8 ms
Rated Output Current5 V DC6.5 A
Excess Current Protection5 V DC7.1 A or more
Excess Voltage Protection5 V DC5.5 to 6.5 V
Efficiency76% or more
Allowable Momentary Power Loss DurationWithin 20 ms
Withstand Voltage2,300 Vrms AC / 1 minute (altitude 0 to 2,000 m)
between all inputs / LG at once and all outputs / FG at once
Insulation ResistanceBetween all inputs / LG at once and all outputs / FG at once, between all inputs at once and LG, between all outputs at once and FG: 10 MΩ or more at 500 V DC on an insulation resistance meter
FuseBuilt-in (cannot be replaced by the user)
Contact Output PartApplicationsERR Contact
Rated Switching Voltage/Current24 V DC, 0.5 A
Minimum Switching Load5 V DC 1 mA
Response TimeOFF→ON10 ms or less
ON→OFF12 ms or less
LifespanMechanical20,000,000 operations or more
ElectricalRated switching voltage/current 100,000 times or more
Surge ProtectorNo
FuseNo
External DimensionsHeight (H)106 mm (98 mm at the base unit mounting part)
Width (W)54.6 mm
Depth (D)110 mm
Mass0.41 kg

 

(Unit: mm)

 

R62P/R63P/R64P dimensional outline drawing

R62P/R63P/R64P dimensional outline drawing

R62P Specifications

Input Power Supply Voltage100 to 240 V AC (85 to 264 V AC)
Input Frequency50/60 Hz ±5%
Input Voltage Strain FactorWithin 5%
Input Maximum Apparent Power120 VA
Inrush Current20 A within 8 ms
Rated Output Current5 V DC3.5 A
24 V DC0.6 A
Excess Current Protection5 V DC3.8 A or more
24 V DC0.66 A or more
Excess Voltage Protection5 V DC5.5 to 6.5 V
Efficiency76% or more
Allowable Momentary Power Loss DurationWithin 20 ms
Withstand Voltage2,300 Vrms AC / 1 minute (altitude 0 to 2,000 m)
between all inputs / LG at once and all outputs / FG at once
Insulation ResistanceBetween all inputs / LG at once and all outputs / FG at once, between all inputs at once and LG, between all outputs at once and FG: 10 MΩ or more at 500 V DC on an insulation resistance meter
FuseBuilt-in (cannot be replaced by the user)
Contact Output PartApplicationsERR Contact
Rated Switching Voltage/Current24 V DC, 0.5 A
Minimum Switching Load5 V DC 1 mA
Response TimeOFF→ON10 ms or less
ON→OFF12 ms or less
LifespanMechanical20,000,000 operations or more
ElectricalRated switching voltage/current 100,000 times or more
Surge ProtectorNo
FuseNo
External DimensionsHeight (H)106 mm (98 mm at the base unit mounting part)
Width (W)54.6 mm
Depth (D)110 mm
Mass0.45 kg

R63P Specifications

Input Power Supply Voltage24 V DC (15.6 to 31.2 V DC)
Input Maximum Power50 W
Inrush Current100 A within 1 ms
Rated Output Current5 V DC6.5 A
Excess Current Protection5 V DC7.1 A or more
Excess Voltage Protection5 V DC5.5 to 6.5 V
Efficiency70% or more
Allowable Momentary Power Loss DurationWithin 10 ms
Withstand Voltage50 V AC / 1 minute (altitude 0 to 2,000 m)
Between primary side and 5 V DC
Insulation ResistanceBetween all inputs / LG at once and all outputs / FG at once, between all inputs at once and LG, between all outputs at once and FG: 10 MΩ or more at 500 V DC on an insulation resistance meter
FuseBuilt-in (cannot be replaced by the user)
Contact Output PartApplicationsERR Contact
Rated Switching Voltage/Current24 V DC, 0.5 A
Minimum Switching Load5 V DC 1 mA
Response TimeOFF→ON10 ms or less
ON→OFF12 ms or less
LifespanMechanical20,000,000 operations or more
ElectricalRated switching voltage/current 100,000 times or more
Surge ProtectorNo
FuseNo
External DimensionsHeight (H)106 mm (98 mm at the base unit mounting part)
Width (W)54.6 mm
Depth (D)110 mm
Mass0.41 kg

R64P Specifications

Input Power Supply Voltage100 to 240 V AC (85 to 264 V AC)
Input Frequency50/60 Hz ±5%
Input Voltage Strain FactorWithin 5%
Input Maximum Apparent Power160 VA
Inrush Current20 A within 8 ms
Rated Output Current5 V DC9 A
Excess Current Protection5 V DC10.0 A or more
Excess Voltage Protection5 V DC5.5 to 6.5 V
Efficiency76% or more
Allowable Momentary Power Loss DurationWithin 20 ms
Withstand Voltage2,300 Vrms AC / 1 minute (altitude 0 to 2,000 m)
between all inputs / LG at once and all outputs / FG at once
Insulation ResistanceBetween all inputs / LG at once and all outputs / FG at once, between all inputs at once and LG, between all outputs at once and FG: 10 MΩ or more at 500 V DC on an insulation resistance meter
FuseBuilt-in (cannot be replaced by the user)
Contact Output PartApplicationsERR Contact
Rated Switching Voltage/Current24 V DC, 0.5 A
Minimum Switching Load5 V DC 1 mA
Response TimeOFF→ON10 ms or less
ON→OFF12 ms or less
LifespanMechanical20,000,000 operations or more
ElectricalRated switching voltage/current 100,000 times or more
Surge ProtectorNo
FuseNo
External DimensionsHeight (H)106 mm (98 mm at the base unit mounting part)
Width (W)54.6 mm
Depth (D)110 mm
Mass0.46 kg

R63RP Specifications

R63RP external appearance

R63RP external appearance

R63RP dimensional outline drawing

R63RP dimensional outline drawing

 

(Unit: mm)

 

Input Power Supply Voltage24 V DC (19.2 to 31.2 V DC)
Input Maximum Power50 W
Inrush Current100 A within 1 ms
Rated Output Current5 V DC6.5 A
Excess Current Protection5 V DC7.1 A or more
Excess Voltage Protection5 V DC5.5 to 6.5 V
Efficiency70% or more
Allowable Momentary Power Loss DurationWithin 10 ms
Withstand Voltage50 V AC / 1 minute (altitude 0 to 2,000 m)
Between primary side and 5 V DC
Insulation ResistanceBetween all inputs / LG at once and all outputs / FG at once, between all inputs at once and LG, between all outputs at once and FG: 10 MΩ or more at 500 V DC on an insulation resistance meter
FuseBuilt-in (cannot be replaced by the user)
Contact Output PartApplicationsERR Contact
Rated Switching Voltage/Current24 V DC, 0.5 A
Minimum Switching Load5 V DC 1 mA
Response TimeOFF→ON10 ms or less
ON→OFF12 ms or less
LifespanMechanical20,000,000 operations or more
ElectricalRated switching voltage/current 100,000 times or more
Surge ProtectorNo
FuseNo
External DimensionsHeight (H)106 mm (98 mm at the base unit mounting part)
Width (W)54.6 mm
Depth (D)110 mm
Mass0.41 kg

R64RP Specifications

R64RP external appearance

R64RP external appearance

R64RP dimensional outline drawing

R64RP dimensional outline drawing

 

(Unit: mm)

 

Input Power Supply Voltage100 to 240 V AC (85 to 264 V AC)
Input Frequency50/60 Hz ±5%
Input Voltage Strain FactorWithin 5%
Input Maximum Apparent Power160 VA
Inrush Current20 A within 8 ms
Rated Output Current5 V DC9 A
Excess Current Protection5 V DC10.0 A or more
Excess Voltage Protection5 V DC5.5 to 6.5 V
Efficiency76% or more
Allowable Momentary Power Loss DurationWithin 20 ms
Withstand Voltage2,300 Vrms AC / 1 minute (altitude 0 to 2,000 m)
between all inputs / LG at once and all outputs / FG at once
Insulation ResistanceBetween all inputs / LG at once and all outputs / FG at once, between all inputs at once and LG, between all outputs at once and FG: 10 MΩ or more at 500 V DC on an insulation resistance meter
FuseBuilt-in (cannot be replaced by the user)
Contact Output PartApplicationsERR Contact
Rated Switching Voltage/Current24 V DC, 0.5 A
Minimum Switching Load5 V DC 1 mA
Response TimeOFF→ON10 ms or less
ON→OFF12 ms or less
LifespanMechanical20,000,000 operations or more
ElectricalRated switching voltage/current 100,000 times or more
Surge ProtectorNo
FuseNo
External DimensionsHeight (H)106 mm (98 mm at the base unit mounting part)
Width (W)54.6 mm
Depth (D)110 mm
Mass0.46 kg
Part Number
R64P
Part NumberStandard Unit PriceMinimum order quantityVolume DiscountDays to Ship

SGD 303.70

1 Piece(s) 20 Day(s)

Loading...

  1. 1
 

Please check the type/dimensions/specifications of the part R64P in the iQ-R Series Power Supply Unit series.

Similar Part Numbers

Part Number
R61P
R62P
R63P
R63RP
R64RP
Part NumberStandard Unit PriceMinimum order quantityVolume DiscountDays to Ship

SGD 173.60

1 Piece(s) 20 Day(s)

SGD 201.30

1 Piece(s) 20 Day(s)

SGD 303.70

1 Piece(s) 91 Day(s)

-

1 Piece(s) Quote

-

1 Piece(s) Quote

Tech Support

Factory Automation, Electronics, Tools, & MRO (Maintenance, Repair and Operations)
Tel:(65) 6733 7211 / FAX:(65) 6733 0211
9:00am - 6:00pm (Monday - Friday)