(!)Due to Microsoft's end of support for Internet Explorer 11 on 15/06/2022, this site does not support the recommended environment.
Instead, please kindly use other browsers like Google Chrome, Microsoft Edge or Mozilla Firefox.
A wide variety of standard and configurable components for factory automation engineers in industries such as automotive, semiconductor, packaging, medical and many more.
A good selection of accessories such as screws, bolts, washers and nuts that you may need for your daily engineering usage.
Browse industrial materials ranging from heat insulating plates, sponges, to metal and plastic materials in different sizes to meet your various applications.
A wide variety of wiring parts for connecting and protecting control and PC parts including Connectors, Cables, Electric Wires, Crimping Terminals and more.
A wide variety of controls and PC parts for electrical engineers including Controls, Powers, PC parts and more.
A wide variety of cutting tools for many uses and work materials including End Mills, Drills, Cutters, Reamers, Turning Tools and more.
A wide variety of tools and supplies used in processing including Machine Tools, Measurement Tools, Grinding and Polishing Supplies and more.
A wide variety of goods used in shipment, material handling and warehouse including Tape supplies, Stretch film, Truck, Shelf, Crane and more.
A large variety of goods for every kind of factories and offices including Protection items, Cleaning supplies, sanitations, office supplies and more.
A large variety of items used in R&D and Clean Room including research Equipment, Laboratory Essentials, Analysis Supplies, Clean Environment-Related Equipment and more.
Choose from thousands of standard stamping die components including Punch & Die, Gas Springs, Guide Components, Coil Springs and many more.
Browse our wide variety of mold components including Ejector Pins, Sleeves, Leader Components, Sprue Bushings and many more.
Browse our injection molding components including Heating Items, Couplers, Hoses and more.
A remote input/output dual use unit for the in-panel/in-device wiring saving network CC-Link/LT.
Part Number
Configured Part Number is shown.
CL2XY16-DTP1C5V
The compact unit is one of the smallest in the industry.
You know where to connect to, just by looking at the nameplate on the terminal block.
Input units share a positive common and a negative common.
The terminal block is structured so that 2‑wire method sensors and loads can be connected directly.
Mounting is possible in six orientations.
Type Name | Input Format | Rated Input Voltage / Current | Number of Input Points | Input Response Time | Output Format | Rated Load Voltage / Current | Number of Output Points | Leak Current When OFF | Output Protection Function | External Connection | ||
---|---|---|---|---|---|---|---|---|---|---|---|---|
CL1XY4-DT1B2 | DC Input | Positive Common / Negative Common | 24 V DC / 4 mA | 2 points | 1.5 ms | Transistor Output | Sink | 12/24 V DC / 0.1 A | 2 points | 0.1 mA or less | No | 2‑wire method |
CL1XY8-DT1B2 | DC Input | Positive Common / Negative Common | 24 V DC / 4 mA | 4 points | 1.5 ms | Transistor Output | Sink | 12/24 V DC / 0.1 A | 4 points | 0.1 mA or less | No | 2-wire method |
CL1XY4-DR1B2 | DC Input | Positive Common / Negative Common | 24 V DC / 4 mA | 2 points | 1.5 ms | Relay Output | - | 30 V DC / 250 V AC 2 A | 2 points | - | No | 2-wire method |
CL1XY8-DR1B2 | DC Input | Positive Common / Negative Common | 24 V DC / 4 mA | 4 points | 1.5 ms | Relay Output | - | 30 V DC / 250 V AC 2 A | 4 points | - | No | 2-wire method |
The compact unit is one of the smallest in the industry.
Two unit mounting methods, DIN rail and screw mounting, to select from.
3‑wire method sensor input is supported.
Type Name | Input Format | Rated Input Voltage / Current | Number of Input Points | Input Response Time | Output Format | Rated Load Voltage / Current | Number of Output Points | Leak Current When OFF | Output Protection Function | External Connection | ||
---|---|---|---|---|---|---|---|---|---|---|---|---|
CL2XY16-DTP1C5V | DC Input | Positive Common | 24 V DC / 4 mA | 8 points | 0.5 ms / 1.5 ms or less | Transistor Output | Sink | 24 V DC, 0.1 A | 8 points | 0.1 mA or less | Available | 3‑wire/2‑wire method |
The compact unit is one of the smallest in the industry.
Storable in a duct, just like cables.
A communication cable and an external equipment connection cable have been integrated for easy wiring.
Both the communication side and the input/output side come with a cable. (50 cm)
Type Name | Input Format | Rated Input Voltage / Current | Number of Input Points | Input Response Time | Output Format | Rated Load Voltage / Current | Number of Output Points | Leak Current When OFF | Output Protection Function | External Connection | ||
---|---|---|---|---|---|---|---|---|---|---|---|---|
CL1XY2-DT1D5S | DC Input | Positive Common | 24 V DC / 4 mA | 1 point | 1.5 ms or less | Transistor Output | Sink | 24 V DC, 0.1 A | 1 point | 0.1 mA or less | No | 3‑wire/2‑wire method |
Part Number |
---|
CL2XY16-DTP1C5V |
Part Number | Standard Unit Price | Minimum order quantity | Volume Discount | Days to Ship | Number Of Inputs | Number of Outputs | Rated load voltage (V) | Protection function | Input answer time | Leakage current when OFF (mA) | Output answer time | Terminal shape | Input target | Rated load current (rated opening/closing current) | External connection | I/O unit power supply current |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
- | 1 Piece(s) | Quote | 8 | 8 | DC24V | Output protection function | 0.5ms/1.5ms | 0.1mA | 1.5ms | Sensor Connectors (e-CON) | Positive Common | 0.1A | 3-line type/2-line type | 50mA |
Loading...
Rated Input Voltage(V) | DC24V | Rated input current(mA) | 4mA |
---|
Please check the type/dimensions/specifications of the part CL2XY16-DTP1C5V in the CC-Link/LT Input/Output Unit (Input/Output) series.
Part Number |
---|
CL1XY4-DR1B2 |
CL1XY8-DR1B2 |
CL1XY8-DT1B2 |
Part Number | Standard Unit Price | Minimum order quantity | Volume Discount | Days to Ship | Number Of Inputs | Number of Outputs | Rated load voltage (V) | Protection function | Input answer time | Leakage current when OFF (mA) | Output answer time | Terminal shape | Input target | Rated load current (rated opening/closing current) | External connection | I/O unit power supply current |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
- | 1 Piece(s) | Quote | 2 | 2 | AC250V/DC30V | - | 1.5ms | Not applicable | 10.0ms | Screw terminal block | Positive/ Negative Common | 2.0A | 2-line type/2-line type | 60mA | ||
- | 1 Piece(s) | Quote | 4 | 4 | AC250V/DC30V | - | 1.5ms | Not applicable | 10.0ms | Screw terminal block | Positive/ Negative Common | 2.0A | 2-line type/2-line type | 70mA | ||
- | 1 Piece(s) | Quote | 4 | 4 | DC12/24V | - | 1.5ms | 0.1mA | 1.0ms | Screw terminal block | Positive/ Negative Common | 0.1A | 2-line type/2-line type | 65mA |
How can we improve?