(!)Due to Microsoft's end of support for Internet Explorer 11 on 15/06/2022, this site does not support the recommended environment.
Instead, please kindly use other browsers like Google Chrome, Microsoft Edge or Mozilla Firefox.

  • Scheduled Maintenance Notice: This site will be unavailable due to scheduled maintenance from 9:00 24/11/2024 to 7:00 (SGT) 25/11/2024. We apologize for the inconvenience.
  • Notice of End of Sales for Economy Series Pneumatic Equipment Category. More information.

CC-Link/LT Input/Output Unit (Input/Output) (CL1XY4-DR1B2)

CC-Link/LT Input/Output Unit (Input/Output) CL1XY4-DR1B2

A remote input/output dual use unit for the in-panel/in-device wiring saving network CC-Link/LT.

PDF

Part Number

Configured Part Number is shown.

CL1XY4-DR1B2

Input/Output Unit Type

Screw Terminal Block Type Features And Specifications

The compact unit is one of the smallest in the industry.
You know where to connect to, just by looking at the nameplate on the terminal block.
Input units share a positive common and a negative common.
The terminal block is structured so that 2‑wire method sensors and loads can be connected directly.
Mounting is possible in six orientations.

Type NameInput FormatRated Input Voltage
/ Current
Number of
Input Points
Input Response TimeOutput FormatRated Load Voltage
/ Current
Number of
Output Points
Leak Current When OFFOutput
Protection Function
External Connection
CL1XY4-DT1B2DC InputPositive Common /
Negative Common
24 V DC / 4 mA2 points1.5 msTransistor OutputSink12/24 V DC / 0.1 A2 points0.1 mA or lessNo2‑wire method
CL1XY8-DT1B2DC InputPositive Common /
Negative Common
24 V DC / 4 mA4 points1.5 msTransistor OutputSink12/24 V DC / 0.1 A4 points0.1 mA or lessNo2-wire method
CL1XY4-DR1B2DC InputPositive Common /
Negative Common
24 V DC / 4 mA2 points1.5 msRelay Output-30 V DC / 250 V AC 2 A2 points-No2-wire method
CL1XY8-DR1B2DC InputPositive Common /
Negative Common
24 V DC / 4 mA4 points1.5 msRelay Output-30 V DC / 250 V AC 2 A4 points-No2-wire method

Sensor Connector Type (e-CON) Features And Specifications

The compact unit is one of the smallest in the industry.
Two unit mounting methods, DIN rail and screw mounting, to select from.
3‑wire method sensor input is supported.

Type NameInput FormatRated Input Voltage
/ Current
Number of
Input Points
Input Response TimeOutput FormatRated Load Voltage
/ Current
Number of
Output Points
Leak Current When OFFOutput
Protection Function
External Connection
CL2XY16-DTP1C5VDC InputPositive Common24 V DC / 4 mA8 points0.5 ms / 1.5 ms or lessTransistor OutputSink24 V DC, 0.1 A8 points0.1 mA or lessAvailable3‑wire/2‑wire method

Cable Type Features And Specifications

The compact unit is one of the smallest in the industry.
Storable in a duct, just like cables.
A communication cable and an external equipment connection cable have been integrated for easy wiring.
Both the communication side and the input/output side come with a cable. (50 cm)

Type NameInput FormatRated Input Voltage
/ Current
Number of
Input Points
Input Response TimeOutput FormatRated Load Voltage
/ Current
Number of
Output Points
Leak Current When OFFOutput
Protection Function
External Connection
CL1XY2-DT1D5SDC InputPositive Common24 V DC / 4 mA1 point1.5 ms or lessTransistor OutputSink24 V DC, 0.1 A1 point0.1 mA or lessNo3‑wire/2‑wire method
Part Number
CL1XY4-DR1B2
Part NumberStandard Unit PriceMinimum order quantityVolume DiscountDays to ShipNumber Of Inputs Number of Outputs Rated load voltage
(V)
Protection function Input answer time Leakage current when OFF
(mA)
Output answer time Terminal shape Input target Rated load current (rated opening/closing current) External connection I/O unit power supply current

-

1 Piece(s) Quote 22AC250V/DC30V-1.5msNot applicable10.0msScrew terminal blockPositive/ Negative Common2.0A2-line type/2-line type60mA

Loading...

  1. 1
 

Basic Information

Rated Input Voltage(V) DC24V Rated input current(mA) 4mA

Please check the type/dimensions/specifications of the part CL1XY4-DR1B2 in the CC-Link/LT Input/Output Unit (Input/Output) series.

Similar Part Numbers

Part Number
CL1XY8-DR1B2
CL1XY8-DT1B2
CL2XY16-DTP1C5V
Part NumberStandard Unit PriceMinimum order quantityVolume DiscountDays to ShipNumber Of Inputs Number of Outputs Rated load voltage
(V)
Protection function Input answer time Leakage current when OFF
(mA)
Output answer time Terminal shape Input target Rated load current (rated opening/closing current) External connection I/O unit power supply current

-

1 Piece(s) Quote 44AC250V/DC30V-1.5msNot applicable10.0msScrew terminal blockPositive/ Negative Common2.0A2-line type/2-line type70mA

-

1 Piece(s) Quote 44DC12/24V-1.5ms0.1mA1.0msScrew terminal blockPositive/ Negative Common0.1A2-line type/2-line type65mA

-

1 Piece(s) Quote 88DC24VOutput protection function0.5ms/1.5ms0.1mA1.5msSensor Connectors (e-CON)Positive Common0.1A3-line type/2-line type50mA

Tech Support

Factory Automation, Electronics, Tools, & MRO (Maintenance, Repair and Operations)
Tel:(65) 6733 7211 / FAX:(65) 6733 0211
9:00am - 6:00pm (Monday - Friday)