(!)Due to Microsoft's end of support for Internet Explorer 11 on 15/06/2022, this site does not support the recommended environment.
Instead, please kindly use other browsers like Google Chrome, Microsoft Edge or Mozilla Firefox.
A wide variety of standard and configurable components for factory automation engineers in industries such as automotive, semiconductor, packaging, medical and many more.
A good selection of accessories such as screws, bolts, washers and nuts that you may need for your daily engineering usage.
Browse industrial materials ranging from heat insulating plates, sponges, to metal and plastic materials in different sizes to meet your various applications.
A wide variety of wiring parts for connecting and protecting control and PC parts including Connectors, Cables, Electric Wires, Crimping Terminals and more.
A wide variety of controls and PC parts for electrical engineers including Controls, Powers, PC parts and more.
A wide variety of cutting tools for many uses and work materials including End Mills, Drills, Cutters, Reamers, Turning Tools and more.
A wide variety of tools and supplies used in processing including Machine Tools, Measurement Tools, Grinding and Polishing Supplies and more.
A wide variety of goods used in shipment, material handling and warehouse including Tape supplies, Stretch film, Truck, Shelf, Crane and more.
A large variety of goods for every kind of factories and offices including Protection items, Cleaning supplies, sanitations, office supplies and more.
A large variety of items used in R&D and Clean Room including research Equipment, Laboratory Essentials, Analysis Supplies, Clean Environment-Related Equipment and more.
Choose from thousands of standard stamping die components including Punch & Die, Gas Springs, Guide Components, Coil Springs and many more.
Browse our wide variety of mold components including Ejector Pins, Sleeves, Leader Components, Sprue Bushings and many more.
Browse our injection molding components including Heating Items, Couplers, Hoses and more.
An analog input unit for the in-line field network CC-Link.
Part Number
Configured Part Number is shown.
Number of Analog Input Points | 4 points (4 channels) | ||
---|---|---|---|
Analog Input | Voltage | -10 to +10 V DC (input resistance: 1 MΩ) | |
Current | -20 to +20 mA DC (input resistance: 250 Ω) | ||
Digital Output | 0 to 4,000, -2,000 to +2,000 | ||
Input/Output Characteristics, Resolution | Input Range | Digital Output Value (Maximum Resolution) | |
Voltage Input | -10 to 10 V | 0 to 4,000 or -2,000 to 2,000 (5 mV) | |
0 to 10 V | 0 to 4,000 or -2,000 to 2,000 (2.5 mV) | ||
0 to 5 V | 0 to 4,000 or -2,000 to 2,000 (1.25 mV) | ||
1 to 5 V | 0 to 4,000 or -2,000 to 2,000 (1.0 mV) | ||
Current Input | -20 to 20 mA | 0 to 4,000 or -2,000 to 2,000 (20 μA) | |
0 to 20 mA | 0 to 4,000 or -2,000 to 2,000 (10 μA / 5 μA) | ||
4 to 20 mA | 0 to 4,000 or -2,000 to 2,000 (4 μA) | ||
Accuracy (Accuracy With Respect to Maximum Digital Output Value) | Ambient Temperature: 0 to 55°C | ±1% | |
A/D Conversion Speed | 1 ms / channel | ||
Absolute Maximum Input | Voltage | ±15 V | |
Current | ±30 mA | ||
Insulation Method | Between power supply / communication system and analog input: opto-isolator insulation Between channels: non-insulated | ||
Dielectric Strength | Between power supply / communication system at once and all analog inputs at once: 500 V AC for 1 minute | ||
Insulation Resistance | Between all power supply / communication systems at once and all analog inputs at once: 10 MΩ or more at 500 V DC on an insulation resistance tester | ||
Station Type | Remote device station (Ver. 1 remote device station) | ||
Number of Occupied Stations | 2 stations | ||
Unit Power Supply | Voltage | 24 V DC (18 to 30 V DC) | |
Current | 0.12 A (when 24 V DC) | ||
External Wiring Connection Method | Communication part, unit power supply part: 7-point 2-piece terminal block (M3.5 screw) Input/output part: 27-point 2-piece terminal block (M3.5 screw) | ||
External Dimensions | Height (H) | 65 mm | |
Width (W) | 151.9 mm | ||
Depth (D) | 63 mm | ||
Weight | 0.35 kg |
Number of Analog Input Points | 4 points (4 channels) | ||
---|---|---|---|
Analog Input | Voltage | -10 to +10 V DC (input resistance: 1 MΩ) | |
Current | 0to 20 mA DC (input resistance: 250 Ω) | ||
Digital Output | -4,096 to +4,095 | ||
Input/Output Characteristics, Resolution | Input Range | Digital Output Value (Maximum Resolution) | |
Voltage Input | -10 to 10 V | -4,000 to 4,000 (2.5 mV) | |
User Range Setting 1 (-10 to 10 V) | -4,000 to 4,000 (2.5 mV) | ||
0 to 5 V | 0 to 4,000 (1.25 mV) | ||
1 to 5 V | 0 to 4,000 (1.0 mV) | ||
User Range Setting 2 (0 to 5 V) | 0 to 4,000 (1.0 mV) | ||
Current Input | 0 to 20 mA | 0 to 4,000 (5 μA) | |
4 to 20 mA | 0 to 4,000 (4 μA) | ||
User Range Setting (0 to 20 mA) | 0 to 4,000 (4 μA) | ||
Accuracy (Accuracy With Respect to Maximum Digital Output Value) | Ambient Temperature: 25±5°C | ±0.2% | |
Ambient Temperature: 0 to 55°C | ±0.4% | ||
A/D Conversion Speed | 1 ms / channel | ||
Absolute Maximum Input | Voltage | ±15 V | |
Current | ±30 mA | ||
Insulation Method | Between communication system and all analog inputs at once: opto-isolator insulation Between power supply system and all analog inputs at once: opto-isolator insulation Between channels: non-insulated | ||
Dielectric Strength | Between power supply / communication system at once and all analog inputs at once: 500 V AC for 1 minute | ||
Station Type | Remote device station (Ver. 1 remote device station) | ||
Number of Occupied Stations | 1 station | ||
Unit Power Supply | Voltage | 24 V DC (20.4 to 26.4 V DC) | |
Current | 0.090 A (at 24 V DC) | ||
Inrush Current | 8.5 A, 2.3 ms or less | ||
External Wiring Connection Method | Communication part, unit power supply part: 7-point 2-piece terminal block (M3 screw) Input/output part: 18-point direct attachment terminal block (M3 screw) | ||
External Dimensions | Height (H) | 50 mm | |
Width (W) | 118 mm | ||
Depth (D) | 40 mm | ||
Weight | 0.20 kg |
Number of Analog Input Points | 8 points (8 channels) | ||
---|---|---|---|
Analog Input | Voltage | 0to 20 mA DC (input resistance: 250 Ω) | |
Digital Output | -96 to +4,095 | ||
Input/Output Characteristics, Resolution | Input Range | Digital Output Value (Maximum Resolution) | |
Current Input | 0 to 20 mA | 0 to 4,000 (5 μA) | |
4 to 20 mA | 0 to 4,000 (4 μA) | ||
User Range Setting (0 to 20 mA) | 0 to 4,000 (4 μA) | ||
Accuracy (Accuracy With Respect to Maximum Digital Output Value) | Ambient Temperature: 25±5°C | ±0.3% | |
Ambient Temperature: 0 to 55°C | ±0.2% | ||
A/D Conversion Speed | 1 ms / channel | ||
Absolute Maximum Input | Current | ±30 mA | |
Insulation Method | Between communication system and all analog inputs at once: opto-isolator insulation Between power supply system and all analog inputs at once: transformer insulation Between channels: non-insulated | ||
Dielectric Strength | Between power supply / communication system at once and all analog inputs at once: 500 V AC for 1 minute | ||
Protection Grade | IP1XB | ||
Station Type | Remote device station (Ver. 1 remote device station or Ver. 2 remote device station) | ||
Number of Occupied Stations | For Ver. 1 remote device station: 3 stations For Ver. 2 remote device station: 1 station (expansion cyclic setting: multiplied by 4) | ||
Communication Cable | Ver. 1.10 supported CC-Link dedicated cable: FANC-110SBH, FA-CBL200PSBH, CS-110 | ||
Unit Power Supply | Voltage | 24 V DC (20.4 to 26.4 V DC; ripple ratio: within 5%) | |
Current | 0.10 A (when 24 V DC) | ||
Inrush Current | 4.2 A, 1.2 ms or less | ||
External Wiring Connection Method | Communication part: single-action connector for communication (sold separately) Unit power supply part: single-action connector for FG / power supply (sold separately) Input/output part: single-action connector for I/O (sold separately) | ||
External Dimensions | Height (H) | 115 mm | |
Width (W) | 41 mm | ||
Depth (D) | 67 mm | ||
Weight | 0.17 kg |
Number of Analog Input Points | 8 points (8 channels) | ||
---|---|---|---|
Analog Input | Voltage | -10 to +10 V DC (input resistance: 1 MΩ) | |
Digital Output | -4,096 to +4,095 | ||
Input/Output Characteristics, Resolution | Input Range | Digital Output Value (Maximum Resolution) | |
Voltage Input | -10 to 10 V | -4,000 to 4,000 (2.5 mV) | |
User Range Setting 1 (-10 to 10 V) | -4,000 to 4,000 (2.5 mV) | ||
0 to 5 V | 0 to 4,000 (1.25 mV) | ||
1 to 5 V | 0 to 4,000 (1.0 mV) | ||
User Range Setting 2 (0 to 5 V) | 0 to 4,000 (1.0 mV) | ||
Accuracy (Accuracy With Respect to Maximum Digital Output Value) | Ambient Temperature: 25±5°C | ±0.3% | |
Ambient Temperature: 0 to 55°C | ±0.2% | ||
A/D Conversion Speed | 1 ms / channel | ||
Absolute Maximum Input | Voltage | ±15 V | |
Insulation Method | Between communication system and all analog inputs at once: opto-isolator insulation Between power supply system and all analog inputs at once: transformer insulation Between channels: non-insulated | ||
Dielectric Strength | Between power supply / communication system at once and all analog inputs at once: 500 V AC for 1 minute | ||
Protection Grade | IP1XB | ||
Station Type | Remote device station (Ver. 1 remote device station or Ver. 2 remote device station) | ||
Number of Occupied Stations | For Ver. 1 remote device station: 3 stations For Ver. 2 remote device station: 1 station (expansion cyclic setting: multiplied by 4) | ||
Communication Cable | Ver. 1.10 supported CC-Link dedicated cable: FANC-110SBH, FA-CBL200PSBH, CS-110 | ||
Unit Power Supply | Voltage | 24 V DC (20.4 to 26.4 V DC; ripple ratio: within 5%) | |
Current | 0.10 A (when 24 V DC) | ||
Inrush Current | 4.2 A, 1.2 ms or less | ||
External Wiring Connection Method | Communication part: single-action connector for communication (sold separately) Unit power supply part: single-action connector for FG / power supply (sold separately) Input/output part: single-action connector for I/O (sold separately) | ||
External Dimensions | Height (H) | 115 mm | |
Width (W) | 41 mm | ||
Depth (D) | 67 mm | ||
Weight | 0.17 kg |
Part Number |
---|
AJ65BT-64AD |
AJ65SBT-64AD |
AJ65VBTCU-68ADIN |
AJ65VBTCU-68ADVN |
Part Number | Standard Unit Price | Minimum order quantity | Volume Discount | Days to Ship | Input Type | Number of Input Channels | Terminal shape | Voltage input range | Current input range |
---|---|---|---|---|---|---|---|---|---|
SGD 569.50 | 1 Piece(s) | 90 Day(s) | Voltage / Current | 4 | Terminal Block | DC-10V to 10V | -20 DC to 20 mA | ||
SGD 389.80 | 1 Piece(s) | 20 Day(s) | Voltage / Current | 4 | Terminal Block | DC-10V to 10V | DC 0–20 mA | ||
SGD 626.20 | 1 Piece(s) | Quote | Current | 8 | Connector | - | DC 0–20 mA | ||
SGD 626.20 | 1 Piece(s) | Quote | Voltage | 8 | Connector | DC-10V to 10V | - |
Loading...
Type | Input | A/D Conversion Speed (Conversion Time) | Less than 1 to 10 mS | Representative Standard | UL |
---|
How can we improve?