Vacuum Release Valve w/Restrictor SY3000, SY5000 (24 V DC) (Part Numbers)

Vacuum Release Valve w/Restrictor SY3000, SY5000 (24 V DC)
  • Economy

An air pressure solenoid valve that allows vacuum suction with a single valve.
[Features]
· Control vacuum suction/release with one valve.
· Adjustable release air flow rate.
· Prevents workpieces from blowing away.
· Pilot specification: External pilot.
· Rated voltage: 24 V DC, 12 V DC.

(i)Caution

  • Refer to the manufacturer's catalog for specification and material details.
  • Product images may be representative images. Refer to the manufacturer's catalog for shape details.

PDF

Vacuum Release Valve w/Restrictor SY3000, SY5000 Specifications

Vacuum Release Valve w/Restrictor SY3000, SY5000 external appearance

Vacuum Release Valve w/Restrictor SY3000, SY5000 external appearance

*This product is the valve. The manifold is not included.

JIS Symbol

JIS Symbol

Valve Specifications Table

Valve Construction3-position 3-port valve with restrictor
Sealing MethodRubber Seal
Usable FluidsAir
Switching MethodNormally closed
Operating Pressure Range MPaRelease pressure port 1 (P)0 to 0.6
Vacuum pressure port 3 (EB), 3/5 (E)-100 kPa to 0.7*1
Pilot X portRelease pressure +0.1 or more (Min.: 0.25) to 0.7
Restrictor operating methodManual operation

*1: Can be used with positive pressure to suit the application.
*2: See the manufacturer's catalog for other specifications.
*3: Quick response type not available.

Response Time

Valve Model NumbersWithout light or surge voltage suppressorWith light and surge voltage suppressor
S, Z TypesR, U Types
SY3A□R182618
SY5A□R273227

*At P = 0.1 MPa, X = 0.5 MPa

Drawings / SY3000

 

(Unit: mm)

 

Side ported type SY3A0R dimensional drawing 1

Side ported type SY3A0R dimensional drawing 1

 

(Unit: mm)

 

Side ported type SY3A0R dimensional drawing 2

Side ported type SY3A0R dimensional drawing 2

Dimensional Outline Drawings / SY5000

 

(Unit: mm)

 

Side ported type, bottom ported type SY5A0R dimensional drawing 1

Side ported type, bottom ported type SY5A0R dimensional drawing 1

 

(Unit: mm)

 

Side ported type, bottom ported type SY5A0R dimensional drawing 2

Side ported type, bottom ported type SY5A0R dimensional drawing 2

 

(Unit: mm)

 

Top ported type SY5A3R dimensional drawing 1

Top ported type SY5A3R dimensional drawing 1

 

(Unit: mm)

 

Top ported type SY5A3R dimensional drawing 2

Top ported type SY5A3R dimensional drawing 2

Circuit Example

Example 1: When the 2-position double solenoid valve is combined with the standalone EXH spacer

Example 1: When the 2-position double solenoid valve is combined with the standalone EXH spacer

Example 2: When the 2-position double solenoid valve is combined with the standalone EXH block and blocking disk

Example 2: When the 2-position double solenoid valve is combined with the standalone EXH block and blocking disk

*Mixing of standard valve types is possible for both internal and external pilot types. However, if there is risk of a pressure drop when the 1 (P) port vacuum is released, make sure to use an external pilot type.

Precautions

  • *Product images may be representative images.
  • *See the SMC catalog for product information other than that detailed above.
Part Number
SY3A0R-5F1
SY3A0R-5F1-B
SY3A0R-5NZ1
SY3A0R-5U1
SY3A0R-5U1-B
SY3A0R-5UD1
SY3A0R-5UE1
SY3A0R-5UE1-B
SY3A0R-5UF1
SY3A0R-5Z1
SY3A0R-5ZD1-B
SY3A0R-5ZE1
SY3A0R-5ZF1
SY3A0R-6U1
SY3A0RT-5Z1
SY3A0RT-5ZD1
SY3A0RT-5ZE1
SY3A0RT-5ZF1
SY3A3R-5U1-C4
SY3A3R-5U1-C6-B
SY3A3R-5UF1-C4
SY5A0R-5NZ1
SY5A0R-5NZD1
SY5A0R-5RF1
SY5A0R-5U1
SY5A0R-5UD1
SY5A0R-5UE1
SY5A0R-5UF1
SY5A0R-5UF1-B
SY5A0R-5Z1
SY5A0RT-5NZ1-B
SY5A0RT-5Z1
SY5A0RT-5Z1-B
SY5A0RT-5ZE1
SY5A0RT-5ZF1
SY5A0RT-5ZF1-B
SY5A3R-5U1-C4
SY5A3R-5U1-C6
SY5A3R-5U1-C8
SY5A3R-5UE1-C6
SY5A3R-5UF1-C4
SY5A3R-5UF1-C6
SY5A3R-5Z1-C6
SY5A3R-5Z1-C8
SY5A3RT-5NZF1-C6
SY5A3RT-5NZF1-C8
SY5A3RT-5Z1-C4
Part NumberStandard Unit PriceMinimum order quantityVolume DiscountDays to ShipVoltage Pipe Port Type Applicable Cylinder Dia.
(Ø)
Plumbing Connecting Tube Diameter Coil specifications Manual Indicator light / Surge voltage suppressor Valve specifications Common specifications Mounting screw type

-

1 Piece(s) Quote DC24V-80 or LessSub-Base Plumbing-StandardSliding type locking systemNone-Non-polarizedSmall cross pan head screw

-

1 Piece(s) Quote DC24V-80 or LessSub-Base Plumbing-StandardSliding type locking systemNone-Non-polarizedHex socket head bolt

-

1 Piece(s) Quote DC24V-80 or LessSub-Base Plumbing-StandardNon-locking, push typeWith indicator light and surge voltage suppressor-Negative commonSmall cross pan head screw

SGD 248.73

1 Piece(s) 32 Day(s) DC24V-80 or LessSub-Base Plumbing-StandardNon-locking, push typeWith indicator light and surge voltage suppressor-Non-polarizedSmall cross pan head screw

-

1 Piece(s) Quote DC24V-80 or LessSub-Base Plumbing-StandardNon-locking, push typeWith indicator light and surge voltage suppressor (non-polar type)SY3000Non-polarizedHex socket head bolt

SGD 248.73

1 Piece(s) 32 Day(s) DC24V-80 or LessSub-Base Plumbing-StandardPush-turn locking screwdriver-operated typeWith indicator light and surge voltage suppressor-Non-polarizedSmall cross pan head screw

-

1 Piece(s) Quote DC24V-80 or LessSub-Base Plumbing-StandardPush-turn locking hand-operated typeWith indicator light and surge voltage suppressor-Non-polarizedSmall cross pan head screw

-

1 Piece(s) Quote DC24V-80 or LessSub-Base Plumbing-StandardPush-turn locking hand-operated typeWith indicator light and surge voltage suppressor-Non-polarizedHex socket head bolt

-

1 Piece(s) Quote DC24V-80 or LessSub-Base Plumbing-StandardSliding type locking systemWith indicator light and surge voltage suppressor-Non-polarizedSmall cross pan head screw

-

1 Piece(s) Quote DC24V-80 or LessSub-Base Plumbing-StandardNon-locking, push typeWith indicator light and surge voltage suppressor-Positive commonSmall cross pan head screw

-

1 Piece(s) Quote DC24V-80 or LessSub-Base Plumbing-StandardPush-turn locking screwdriver-operated typeWith indicator light and surge voltage suppressor-Positive commonHex socket head bolt

-

1 Piece(s) Quote DC24V-80 or LessSub-Base Plumbing-StandardPush-turn locking hand-operated typeWith indicator light and surge voltage suppressor-Positive commonSmall cross pan head screw

-

1 Piece(s) Quote DC24V-80 or LessSub-Base Plumbing-StandardSliding type locking systemWith indicator light and surge voltage suppressor-Positive commonSmall cross pan head screw

-

1 Piece(s) Quote DC12V-80 or LessSub-Base Plumbing-StandardNon-locking, push typeWith indicator light and surge voltage suppressor-Non-polarizedSmall cross pan head screw

-

1 Piece(s) Quote DC24V-80 or LessSub-Base Plumbing-With energy-saving circuit (long time continuous energizing type)Non-locking, push typeWith indicator light and surge voltage suppressor-Positive commonSmall cross pan head screw

-

1 Piece(s) Quote DC24V-80 or LessSub-Base Plumbing-With energy-saving circuit (long time continuous energizing type)Push-turn locking screwdriver-operated typeWith indicator light and surge voltage suppressor-Positive commonSmall cross pan head screw

-

1 Piece(s) Quote DC24V-80 or LessSub-Base Plumbing-With energy-saving circuit (long time continuous energizing type)Push-turn locking hand-operated typeWith indicator light and surge voltage suppressor-Positive commonSmall cross pan head screw

-

1 Piece(s) Quote DC24V-80 or LessSub-Base Plumbing-With energy-saving circuit (long time continuous energizing type)Sliding type locking systemWith indicator light and surge voltage suppressor-Positive commonSmall cross pan head screw

-

1 Piece(s) Quote DC24VOne-Touch Plumbing80 or LessDirect PlumbingØ4StandardNon-locking, push typeWith indicator light and surge voltage suppressorSY3000Non-polarizedSmall cross pan head screw

-

1 Piece(s) Quote DC24VOne-Touch Plumbing80 or LessDirect PlumbingØ6StandardNon-locking, push typeWith indicator light and surge voltage suppressorSY3000Non-polarizedHex socket head bolt

-

1 Piece(s) Quote DC24VOne-Touch Plumbing80 or LessDirect PlumbingØ4StandardSliding type locking systemWith indicator light and surge voltage suppressorSY3000Non-polarizedSmall cross pan head screw

-

1 Piece(s) Quote DC24V-125 or lessSub-Base Plumbing-StandardNon-locking, push typeWith indicator light and surge voltage suppressor-Negative commonSmall cross pan head screw

-

1 Piece(s) Quote DC24V-125 or lessSub-Base Plumbing-StandardPush-turn locking screwdriver-operated typeWith indicator light and surge voltage suppressor-Negative commonSmall cross pan head screw

-

1 Piece(s) Quote DC24V-125 or lessSub-Base Plumbing-StandardSliding type locking systemWith surge voltage suppressor-Non-polarizedSmall cross pan head screw

-

1 Piece(s) Quote DC24V-125 or lessSub-Base Plumbing-StandardNon-locking, push typeWith indicator light and surge voltage suppressor-Non-polarizedSmall cross pan head screw

-

1 Piece(s) Quote DC24V-125 or lessSub-Base Plumbing-StandardPush-turn locking screwdriver-operated typeWith indicator light and surge voltage suppressor-Non-polarizedSmall cross pan head screw

-

1 Piece(s) Quote DC24V-125 or lessSub-Base Plumbing-StandardPush-turn locking hand-operated typeWith indicator light and surge voltage suppressor-Non-polarizedSmall cross pan head screw

SGD 267.40

1 Piece(s) 32 Day(s) DC24V-125 or lessSub-Base Plumbing-StandardSliding type locking systemWith indicator light and surge voltage suppressor-Non-polarizedSmall cross pan head screw

-

1 Piece(s) Quote DC24V-125 or lessSub-Base Plumbing-StandardSliding type locking systemWith indicator light and surge voltage suppressor-Non-polarizedHex socket head bolt

-

1 Piece(s) Quote DC24V-125 or lessSub-Base Plumbing-StandardNon-locking, push typeWith indicator light and surge voltage suppressor-Positive commonSmall cross pan head screw

-

1 Piece(s) Quote DC24V-125 or lessSub-Base Plumbing-With energy-saving circuit (long time continuous energizing type)Non-locking, push typeWith indicator light and surge voltage suppressorSY5000Negative commonHex socket head bolt

-

1 Piece(s) Quote DC24V-125 or lessSub-Base Plumbing-With energy-saving circuit (long time continuous energizing type)Non-locking, push typeWith indicator light and surge voltage suppressor-Positive commonSmall cross pan head screw

-

1 Piece(s) Quote DC24V-125 or lessSub-Base Plumbing-With energy-saving circuit (long time continuous energizing type)Non-locking, push typeWith indicator light and surge voltage suppressorSY5000Positive commonHex socket head bolt

-

1 Piece(s) Quote DC24V-125 or lessSub-Base Plumbing-With energy-saving circuit (long time continuous energizing type)Push-turn locking hand-operated typeWith indicator light and surge voltage suppressor-Positive commonSmall cross pan head screw

-

1 Piece(s) Quote DC24V-125 or lessSub-Base Plumbing-With energy-saving circuit (long time continuous energizing type)Sliding type locking systemWith indicator light and surge voltage suppressor-Positive commonSmall cross pan head screw

-

1 Piece(s) Quote DC24V-125 or lessSub-Base Plumbing-With energy-saving circuit (long time continuous energizing type)Sliding type locking systemWith indicator light and surge voltage suppressor-Positive commonHex socket head bolt

-

1 Piece(s) Quote DC24VOne-Touch Plumbing125 or lessDirect PlumbingØ4StandardNon-locking, push typeWith indicator light and surge voltage suppressor-Non-polarizedSmall cross pan head screw

-

1 Piece(s) Quote DC24VOne-Touch Plumbing125 or lessDirect PlumbingØ6StandardNon-locking, push typeWith indicator light and surge voltage suppressor-Non-polarizedSmall cross pan head screw

-

1 Piece(s) Quote DC24VOne-Touch Plumbing125 or lessDirect PlumbingØ8StandardNon-locking, push typeWith indicator light and surge voltage suppressor-Non-polarizedSmall cross pan head screw

-

1 Piece(s) Quote DC24VOne-Touch Plumbing125 or lessDirect PlumbingØ6StandardPush-turn locking hand-operated typeWith indicator light and surge voltage suppressorSY5000Non-polarizedSmall cross pan head screw

-

1 Piece(s) Quote DC24VOne-Touch Plumbing125 or lessDirect PlumbingØ4StandardSliding type locking systemWith indicator light and surge voltage suppressor-Non-polarizedSmall cross pan head screw

-

1 Piece(s) Quote DC24VOne-Touch Plumbing125 or lessDirect PlumbingØ6StandardSliding type locking systemWith indicator light and surge voltage suppressor-Non-polarizedSmall cross pan head screw

SGD 262.03

1 Piece(s) 32 Day(s) DC24VOne-Touch Plumbing125 or lessDirect PlumbingØ6StandardNon-locking, push typeWith indicator light and surge voltage suppressor-Positive commonSmall cross pan head screw

-

1 Piece(s) Quote DC24VOne-Touch Plumbing125 or lessDirect PlumbingØ8StandardNon-locking, push typeWith indicator light and surge voltage suppressor-Positive commonSmall cross pan head screw

-

1 Piece(s) Quote DC24VOne-Touch Plumbing125 or lessDirect PlumbingØ6With energy-saving circuit (long time continuous energizing type)Sliding type locking systemWith indicator light and surge voltage suppressorSY5000Negative commonSmall cross pan head screw

-

1 Piece(s) Quote DC24VOne-Touch Plumbing125 or lessDirect PlumbingØ8With energy-saving circuit (long time continuous energizing type)Sliding type locking systemWith indicator light and surge voltage suppressor-Negative commonSmall cross pan head screw

-

1 Piece(s) Quote DC24VOne-Touch Plumbing125 or lessDirect PlumbingØ4With energy-saving circuit (long time continuous energizing type)Non-locking, push typeWith indicator light and surge voltage suppressor-Positive commonSmall cross pan head screw

Loading...

  1. 1

Basic Information

Type Solenoid Valves Application Unit for Manifold Mounting Number of Ports 3-Port Valve
Mounting Orientation Manifold Base Specifications Standard Number of Solenoids Single
Switching Type 3 positions 3 ports Status at Power Off Self-Recovery (Pressure Differential Return) Driving Type Pilot Type Spool
Seal Type Soft Seal Pressure Rating(MPa) -0.1 to 0.7 Pilot Air Supply External