(!)Due to Microsoft's end of support for Internet Explorer 11 on 15/06/2022, this site does not support the recommended environment.
Instead, please kindly use other browsers like Google Chrome, Microsoft Edge or Mozilla Firefox.

  • Scheduled Maintenance Notice: This site will be unavailable due to scheduled maintenance from 9:00 24/11/2024 to 7:00 (SGT) 25/11/2024. We apologize for the inconvenience.
  • Notice of End of Sales for Economy Series Pneumatic Equipment Category. More information.

Control/Instrumentation Cables(Insulation body materials:Polyethylene-Based)

Control and instrumentation cables are used for device controls and signal transmissions to and from terminal devices. Control cables are mainly used to control devices in plants and factories. For this reason, insulated vinyl sheath cables with PVC and polyethylene insulation are usually used for their highly flame retardant properties and excellent oil resistance, weather resistance and water resistance. Instrumentation cables are used in a wide range of applications including transmitting computer signals, electronic controls for industrial equipment, etc. Insulated vinyl sheath cables with polyethylene insulators are often used for their capacitance and noise reduction characteristics. The cables are selected for length and number of pairs, but other specific properties should also be considered, such as abrasion resistance and chemical resistance.
Days to Ship
  • All
  • Same day
  • 3 Day(s) or Less
  • 4 Day(s) or Less
  • 5 Day(s) or Less
  • 6 Day(s) or Less
  • 7 Day(s) or Less
  • 8 Day(s) or Less
  • 9 Day(s) or Less
  • 10 Day(s) or Less
  • 11 Day(s) or Less
  1. 1
Brand
Product Series
Days to Ship
Specifications
Overall Length(m)
Specified Length(m)
Conductor Cross Section(mm2)
AWG size(AWG)
Number Of Cores(Core)
Logarithm
Finished outer diameter(mm)
Rated Voltage
Shield
Properties
Representative Standard
Sheath (outer coating) color
Grounding Wire
Sheath (outer coating) material
Insulation body materials

    FCPEV Color Identifiable with Shield for Communication

      Instrumentation Cable, FKEV-SB

        CL2/2464-3599-DS LF

          KFPEV-SB Cable for Light Electrical Appliances and Instrumentation

            NA20276HB Cross-Linked Polyethylene UL with Shield

              NA20276H Cross-Linked Polyethylene UL-Supported

                Polyethylene Insulation Vinyl Sheath Instrumentation Cable J-KNPEV-SB

                Brand

                MISUMI

                FUJI ELECTRIC WIRE INDUSTRIES

                TAIYO CABLETEC

                FUJI ELECTRIC CABLE

                MISUMI

                MISUMI

                NIHON ELECTRIC WIRE & CABLE

                Product Series

                FCPEV Color Identifiable with Shield for Communication

                Instrumentation Cable, FKEV-SB

                CL2/2464-3599-DS LF

                KFPEV-SB Cable for Light Electrical Appliances and Instrumentation

                NA20276HB Cross-Linked Polyethylene UL with Shield

                NA20276H Cross-Linked Polyethylene UL-Supported

                Polyethylene Insulation Vinyl Sheath Instrumentation Cable J-KNPEV-SB

                Days to Ship 3 Day(s) or more 4 Day(s) or more 4 Day(s) or more 8 Day(s) or more 3 Day(s) or more 3 Day(s) or more 4 Day(s) or more
                Specifications
                • For Signal
                • Oil-Resistant
                • Single Shield
                • Twisted Pair
                • Less than 100 V
                      • VW-1
                      • ULAWM
                      • Oil-Resistant
                      • Strand Wire
                      • Single Shield
                      • Twisted Pair
                      • 30 V
                      • VW-1
                      • ULAWM
                      • Oil-Resistant
                      • Strand Wire
                      • Small Diameter
                      • 30 V
                        Overall Length(m)-1 ~ 1001 ~ 100-1001001 ~ 100
                        Specified Length(m)---100---
                        Conductor Cross Section(mm2)0.9 ~ 1.20.3 ~ 1.250.204 ~ 0.8230.5 ~ 1.250.12 ~ 0.30.12 ~ 0.30.2 ~ 2
                        AWG size(AWG)--18 ~ 2416 ~ 2022 ~ 2622 ~ 2614 ~ 24
                        Number Of Cores(Core)-2 ~ 20-2 ~ 6032 ~ 202 ~ 60
                        Logarithm1P ~ 10P1 ~ 101P ~ 5P1P ~ 30P1P ~ 20P-1P ~ 30P
                        Finished outer diameter(mm)7 ~ 145 ~ 205.1 ~ 147 ~ 32.54.3 ~ 11.83.7 ~ 8.65.5 ~ 28
                        Rated VoltageFor Low Current CircuitsOtherFor Low Current Circuits-For Low Current CircuitsFor Low Current Circuits-
                        ShieldAvailableAvailableAvailableAvailableAvailableNAAvailable
                        PropertiesOil ResistanceOil Resistance / Heat-ResistanceOil Resistance / Heat-Resistance-Oil ResistanceOil ResistanceOil Resistance / Heat-Resistance
                        Representative Standard--UL / CSA(c-UL)-ULUL-
                        Sheath (outer coating) colorBlackGrayBlackBlackBlueBlueBlack
                        Grounding Wire-OtherNANA--NA
                        Sheath (outer coating) materialPVC (Polyvinyl Chloride)PVC (Polyvinyl Chloride)PVC (Polyvinyl Chloride)PVC (Polyvinyl Chloride)PVC (Polyvinyl Chloride)PVC (Polyvinyl Chloride)-
                        Insulation body materialsPolyethylene-BasedPolyethylene-BasedPolyethylene-BasedPolyethylene-BasedPolyethylene-BasedPolyethylene-BasedPolyethylene-Based