(!)Due to Microsoft's end of support for Internet Explorer 11 on 15/06/2022, this site does not support the recommended environment.
Instead, please kindly use other browsers like Google Chrome, Microsoft Edge or Mozilla Firefox.
A wide variety of standard and configurable components for factory automation engineers in industries such as automotive, semiconductor, packaging, medical and many more.
A good selection of accessories such as screws, bolts, washers and nuts that you may need for your daily engineering usage.
Browse industrial materials ranging from heat insulating plates, sponges, to metal and plastic materials in different sizes to meet your various applications.
A wide variety of wiring parts for connecting and protecting control and PC parts including Connectors, Cables, Electric Wires, Crimping Terminals and more.
A wide variety of controls and PC parts for electrical engineers including Controls, Powers, PC parts and more.
A wide variety of cutting tools for many uses and work materials including End Mills, Drills, Cutters, Reamers, Turning Tools and more.
A wide variety of tools and supplies used in processing including Machine Tools, Measurement Tools, Grinding and Polishing Supplies and more.
A wide variety of goods used in shipment, material handling and warehouse including Tape supplies, Stretch film, Truck, Shelf, Crane and more.
A large variety of goods for every kind of factories and offices including Protection items, Cleaning supplies, sanitations, office supplies and more.
A large variety of items used in R&D and Clean Room including research Equipment, Laboratory Essentials, Analysis Supplies, Clean Environment-Related Equipment and more.
Choose from thousands of standard stamping die components including Punch & Die, Gas Springs, Guide Components, Coil Springs and many more.
Browse our wide variety of mold components including Ejector Pins, Sleeves, Leader Components, Sprue Bushings and many more.
Browse our injection molding components including Heating Items, Couplers, Hoses and more.
Days to Ship |
|
---|
MITSUBISHI
- I/O module, iQ-R series from MITSUBISHI.
- Input/output rating is printed at the front, reducing incorrect wiring.
- Easy-to-use cable tie hook for tidy wiring.
- Existing 16-point terminal blocks are reusable, eliminating rewiring.
- Simple confirmation by product serial no. printed on the front.
- Alternating toggle switch used to display between 32-point LED signals.
- Terminal signals are clearly labeled and color-coded.
- Up to 32 LED signals clearly visible.
Standard Price: | SGD 166.60- |
---|---|
Days to Ship: | 2 Day(s) or more |
MELSEC-F Input/Output Expansion Block
MITSUBISHI
An input/output expansion block that can receive power supply from a basic power supply unit.
[Features]
· Can expand input by 16 points.
· Can be connected to the back of a basic unit or expansion unit.
[Applications]
· Convenient for expanding input/output, receiving power supply from a basic unit or expansion unit.
Days to Ship: | 20 Day(s) or more |
---|
MELSEC-F Series Input/Output Expansion Unit
MITSUBISHI
- PLC Input/Output Expansion Unit, MELSEC-F Series from MITSUBISHI.
- The FX2N series extension units are available with 8 or 48 integrated I/O with selectable relay or transistor output models.
- Input and output indicator LEDs.
- Removable terminal blocks.
- Integrated service power supply with up to 250 mA or 460 mA capacity.
- This limitation applies to the maximum output current for each reference terminal (Common), each serving 1 to 4 relay or transistor outputs. Please observe the reference terminal assignments for group identification.
Days to Ship: | 20 Day(s) or more |
---|
Standard Price: | SGD 257.73- |
---|---|
Days to Ship: | Same day or more |
Standard Price: | SGD 204.30- |
---|---|
Special Price | |
Days to Ship: | Same day or more |
MELSEC iQ-F Series Spring Clamp Terminal Block Type I/O Unit
MITSUBISHI
- MELSEC iQ-F Series Spring Clamp Terminal Block Type I/O Unit from MITSUBISHI.
- No crimp connectors and crimp tools are needed. Wiring can be performed just by preparing cables, and wiring man-hours can be reduced.
- Compact, lightweight body also cuts shipping costs. Build systems containing both relay outputs and transistor outputs.
- Simple CPU communication function, Device information can be shared with simple parameter settings, so the programming man-hours can be reduced.
- Web server function, View the system status even from a remote location.
Standard Price: | SGD 246.40- |
---|---|
Days to Ship: | 91 Day(s) |
CC-Link IE Field Network, Block Type Remote Unit NZ2GF Series
MITSUBISHI
[CC-Link IE Field Network, Block Type Remote Unit]
・ CC-Link IE field network remote device station. Input/output devices can be more easily distributed according to the equipment
・ You can easily add the number of input/output points by connecting expansion units
・ It supports CC-Link IE field network synchronous communication function. Since the operation can be performed according to the synchronization cycle of the master station that supports the synchronous communication function, the operation timings of multiple slave stations can be aligned
・ Units that support the fast link-up function can quickly return to the line when the CC-Link IE field network is disconnected and then reconnected
・ Units that support the automatic I/O parameter setting function can operate the input/output unit without setting parameters, so the startup time can be shortened
Days to Ship: | Quote |
---|
NX Series Digital Input Unit NX-ID DC Input Unit
OMRON
Digital input unit that is available in many variations, from high-speed types that enable high-speed synchronization control to general-purpose types
■ Features
· Can be mounted on an EtherCAT coupler to enable high-speed I/O refreshing
· Enables I/O refreshing synchronized with the controller control period (synchronous refresh)
· Using this unit in combination with an NX Series CPU Unit or EtherCAT Coupler Unit, an NX unit that uses a time-stamping input method,
and an NX unit that uses a time-specific output method enables highly precise I/O control that does not depend on the
controller's control period
· The use of a removable terminal block improves system maintainability
· The Push-In Plus terminal block (screwless clamp terminal block) and connector type (MIL connector / Fujitsu connector)
greatly reduce the time required for wiring work
· A unit width of only 12 mm realizes space saving (connector type 30 mm)
· 4-, 8-, 16- and 32-input-contact types are available, enabling the I/O configuration that best suits your equipment
· Connect to the CJ Series using the EtherNet/IP coupler
Standard Price: | SGD 134.17- |
---|---|
Days to Ship: | 4 Day(s) or more |
I/O Unit For MELSEC iQ-FX5 Series
MITSUBISHI
- I/O Unit for MELSEC iQ-FX5 Series, Analog control type from MITSUBISHI.
- Using analog input and output devices, operations such as input and output of analog quantities (voltage, current, etc.), temperature input and adjustment, etc. can be performed.
- Use the ample lineup of extension modules for analog control that matches your applications.
- 3 types available, Analog input (FX5-4AD), Analog Output (FX5-4DA) and Temperature control (FX5-4LC, FX5-8AD)
- I/O channel can be selected up to 8 channels.
Standard Price: | SGD 503.30- |
---|---|
Days to Ship: | 20 Day(s) or more |
OMRON
An input/output unit for SYSMAC CS1.
[Features]
·Number of inputs: 16, 32, 48, 64, 96.
·Number of outputs: 8, 16, 32, 48, 64, 96.
[Applications]
·For SYSMAC CS1.
Standard Price: | SGD 299.79- |
---|---|
Days to Ship: | 4 Day(s) or more |
Standard Price: | SGD 420.32 |
---|---|
Days to Ship: | 4 Day(s) or more |
NX Series Digital Output Unit NX-OD Transistor Output Unit
OMRON
Digital output unit that is available in many variations, from high-speed types that enable high-speed synchronization control to general-purpose types
■ Features
· Can be mounted on an EtherCAT coupler to enable high-speed I/O refreshing
· Enables I/O refreshing synchronized with the controller control period (synchronous refresh)
· Using this unit in combination with an NX Series CPU Unit or EtherCAT Coupler Unit, an NX unit that uses a time stamping input method,
and an NX unit that uses a time-specific output method enables highly precise I/O control that does not depend on the
controller's control period
· The use of a removable terminal block improves system maintainability
· The Push-In Plus terminal block (screwless clamp terminal block) and connector type (MIL connector / Fujitsu connector)
greatly reduce the time required for wiring work
· A unit width of only 12 mm realizes space saving (connector type 30 mm)
· 2-, 4-, 8-, 16- and 32-output-contact types are available, enabling the I/O configuration that best suits your equipment
· Connect to the CJ Series using the EtherNet/IP coupler
Standard Price: | SGD 134.17- |
---|---|
Days to Ship: | 4 Day(s) or more |
CC-Link IE Field Network Basic, Block Type Remote Unit
MITSUBISHI
[CC-Link IE Field Network, Basic Block Type Remote Unit]
・ CC-Link IE field network Basic slave station. Input/output devices can be more easily distributed according to the equipment
・ It supported for CC-Link IE Field Network Basic diagnostic function. With the engineering tool, you can check for network abnormalities and input/output unit abnormalities
・ Parameters can be easily set with just a switch operation
Days to Ship: | Quote |
---|
Standard Price: | SGD 1,281.39 |
---|---|
Days to Ship: | 4 Day(s) or more |
Standard Price: | SGD 193.97- |
---|---|
Days to Ship: | 4 Day(s) or more |
MELSEC iQ-F Input/Output Expansion Block (Input/Output Unit) FX5
MITSUBISHI
Input/output expansion block that receives power from the basic / power supply unit of the MELSEC iQ-F series.
[Features]
・ It can be connected to the back of a basic unit or expansion unit
[Applications]
・ Convenient for expanding input/output, receiving power supply from a basic unit or expansion unit
・ It can be used for FX5UJ, FX5U, FX5UC, etc.
Standard Price: | SGD 246.40- |
---|---|
Days to Ship: | 91 Day(s) |
MELSEC-L Series Input/Output Unit
MITSUBISHI
- Output module, MELSEC-L Series from MITSUBISHI.
- 2 Output types available, Contact output (LY10R2) and Transistor output Sink type (LY41NT1P, LY42NT1P)
- No. of output: 16 points (LY10R2), 32 points (LY41NT1P) and 64 points (LY42NT1P)
- Rated switching voltage: 24 V DC / 240 V AC (LY10R2), 12 to 24 V DC (LY41NT1P, LY42NT1P)
- Response time: Contact output module (≤ 12 ms), Transistor output Sink type (≤ 1 ms)
Days to Ship: | Quote |
---|
Standard Price: | SGD 676.39 |
---|---|
Days to Ship: | 4 Day(s) or more |
Standard Price: | SGD 457.38- |
---|---|
Days to Ship: | 4 Day(s) or more |
CS1D series I/O interface unit
OMRON
CS1D Series I/O interface unit. Connection terminal / connector
Standard Price: | SGD 928.07 |
---|---|
Days to Ship: | 4 Day(s) or more |
Standard Price: | SGD 1,601.70- |
---|---|
Days to Ship: | 4 Day(s) or more |
Standard Price: | SGD 169.00- |
---|---|
Days to Ship: | 60 Day(s) or more |
Days to Ship: | Quote |
---|
MITSUBISHI
- CT input module, MELSEC-Q series from MITSUBISHI.
- The direct connection of the CT (Current Transformer) sensor and the programmable controller has eliminated the need to connect a separate signal converter.
- Direct CT (Current Transformer) sensor connection reduces wiring and saves space. Directly connect to the CT sensor without an external signal converter. The AC current for up to eight channels can be measured with one unit, by that reducing the wiring steps and costs.
- The device can be serviced, and troubleshooting is performed by detecting the peak current.
Standard Price: | SGD 1,106.30 |
---|---|
Days to Ship: | Quote |
NX Series Digital Input/Output Combined Unit NX-MD DC Input / Transistor Output Unit
OMRON
Digital input unit that is available in many variations, from high-speed types that enable high-speed synchronization control to general-purpose types
■ Features
· Can be mounted on an EtherCAT coupler to enable high-speed I/O refreshing
· Enables I/O refreshing synchronized with the controller control period (synchronous refresh)
· Using this unit in combination with an NX Series CPU Unit or EtherCAT Coupler Unit, an NX unit that uses a time-stamping input method,
and an NX unit that uses a time-specific output method enables highly precise I/O control that does not depend on the
controller's control period
· The use of a removable terminal block improves system maintainability
· The Push-In Plus terminal block (screwless clamp terminal block) and connector type (MIL connector / Fujitsu connector)
greatly reduce the time required for wiring work
· A unit width of only 12 mm realizes space saving (connector type 30 mm)
· Connect to the CJ Series using the EtherNet/IP coupler
Standard Price: | SGD 406.02 |
---|---|
Days to Ship: | 4 Day(s) or more |
NX Series Incremental Encoder Input Unit NX-EC0□□□
OMRON
Enables more precise timing control by synchronizing the encoder data with the time data
■ Features
· Open-collector-output type and line-driver-output type incremental encoders can be connected
· High-speed remote I/O control with communications cycle as fast as 125 μs*1
· Free-run refreshing, synchronous I/O refreshing, or
task period prioritized refreshing*2 with the NX1P2 CPU Unit or EtherCAT Coupler Unit
· The MC Function Module of the NJ/NX/NY5 Controllers allows the encoder
to be used as a motion axis
· Latching (1 internal signal and 2 input signals from external devices)
· Pulse period measurement
· 32-bit counters (80000000 to 7FFFFFFF HEX)
· Maximum counting rate: 4 MHz (Line receiver: 4 MHz; Open collector: 500 kHz)
· Time stamping
· Maximum and minimum counter value setting
· Connect to the CJ PLC using the EtherNet/IP coupler
*1 When using the NX-EC01□□ together with the NX701-□□□□ and NX-ECC203.
*2 Task period prioritized refreshing is available when the NX-ECC203 is used together.
**ขอราคาวันนี้ รับเลยของรางวัล ไม่ต้องลุ้น ถึง 31 ต.ค.นี้ ดูรายละเอียด ที่นี่
Standard Price: | SGD 931.98- |
---|---|
Days to Ship: | 4 Day(s) or more |
NX Series Position Interface Pulse Output Unit NX-PG0□□□
OMRON
Positioning control with pulse outputs to command stepper motor drives and other pulse input motor drives
■ Features
· The MC Function Module of the NJ/NX/NY5 Controller allows you to
connect with as many axes as the NJ/NX/NY5 Controller can control
· High-speed remote I/O control with communications cycle as fast as 125 μs*1
· Multiple stepping motors and servo motors can be operated in synchronization by
using synchronous I/O refreshing or task period prioritized refreshing*2
· Latching (2 external latch inputs)
· Open collector pulse outputs up to 500 kHz
or line driver pulse outputs up to 4 MHz
· Line driver output models with 2 or 4 channels
*1 When using the NX-EC01□□ together with the NX701-□□□□ and NX-ECC203.
* *2 Task period prioritized refreshing is available when the NX-ECC203 is used together.
Standard Price: | SGD 591.70- |
---|---|
Days to Ship: | 4 Day(s) or more |
Brand |
---|
Product Series |
Days to Ship |
Number Of Inputs |
Input Format |
Rated Input Voltage(V) |
Input answer time |
Number of Outputs |
Output Format |
Rated load voltage(V) |
Protection function |
Connection Terminal |
Representative Standard |
| |||||||||||||||||||||||||||
Brand | MITSUBISHI | MITSUBISHI | MITSUBISHI | OMRON | OMRON | MITSUBISHI | MITSUBISHI | OMRON | MITSUBISHI | OMRON | OMRON | OMRON | MITSUBISHI | OMRON | OMRON | MITSUBISHI | MITSUBISHI | OMRON | OMRON | OMRON | OMRON | MITSUBISHI | MITSUBISHI | MITSUBISHI | OMRON | OMRON | OMRON |
Product Series | MELSEC iQ-F Series Spring Clamp Terminal Block Type I/O Unit | CC-Link IE Field Network, Block Type Remote Unit NZ2GF Series | MELSEC iQ-F Input/Output Expansion Block (Input/Output Unit) FX5 | NX Series Digital Input/Output Combined Unit NX-MD DC Input / Transistor Output Unit | |||||||||||||||||||||||
Days to Ship | 2 Day(s) or more | 20 Day(s) or more | 20 Day(s) or more | Same day or more | Same day or more | 91 Day(s) | Quote | 4 Day(s) or more | 20 Day(s) or more | 4 Day(s) or more | 4 Day(s) or more | 4 Day(s) or more | Quote | 4 Day(s) or more | 4 Day(s) or more | 91 Day(s) | Quote | 4 Day(s) or more | 4 Day(s) or more | 4 Day(s) or more | 4 Day(s) or more | 60 Day(s) or more | Quote | Quote | 4 Day(s) or more | 4 Day(s) or more | 4 Day(s) or more |
Number Of Inputs | 8 ~ NA | 8 ~ NA | NA | 8 ~ 64 | - | 16 ~ NA | - | 4 ~ 16 | 4 ~ 8 | 16 ~ 96 | 10 | - | - | - | 1 ~ 8 | - | - | 16 | 16 ~ 32 | - | - | - | - | - | 16 | - | - |
Input Format | DC input / AC input | - | - | DC input / AC input | - | DC input | DC input | - | - | DC input / AC input / AC/DC input | - | - | - | DC input | DC input | DC input | - | DC input | DC input | - | DC input | - | - | - | DC input | Other | - |
Rated Input Voltage(V) | DC5 ~ AC100 to 240 | DC24V ~ NA | DC24V ~ (Not applicable) | 24 ~ 200 to 240 | - | DC5/24 | - | 12 to 24 ~ 24 | DC-10~+10 | 24 ~ 200 to 240 | - | - | - | - | 12–24 | DC13 to 30 | - | 24 | 5 ~ 24 | - | - | - | - | - | 24 | - | - |
Input answer time | Less than 10 to 20 mS / Less than 50 to 100 mS | - | - | - | - | Less than 1 mS / Less than 10 to 20 mS | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
Number of Outputs | 8 ~ NA | 0 ~ NA | 24 ~ NA | - | 8 ~ 64 | 16 ~ NA | - | - | 4 | 8 ~ 64 | 6 | 4 ~ 32 | - | - | 1 | - | 16 ~ 64 | - | 16 ~ 32 | - | - | - | - | - | 16 | - | - |
Output Format | Relay contact output / Triac output / Transistor / source output / Transistor / sync output / Other | Relay contact output / Transistor / source output / Transistor / sync output / Other | Relay contact output / Transistor / source output | - | Relay contact output / Triac output / Transistor / source output / Transistor / sync output | Relay contact output / Transistor / source output / Transistor / sync output | Transistor / source output / Transistor / sync output | - | Transistor / sync output | Relay contact output / Triac output / Transistor / source output / Transistor / sync output | Transistor / sync output | Other | Transistor / source output / Transistor / sync output | - | - | Transistor / source output / Transistor / sync output | - | - | Transistor / source output / Transistor / sync output | - | - | - | - | - | Other | - | Other |
Rated load voltage(V) | DC5 to 24 ~ AC100~240 | - | - | - | - | - | 12/24 ~ 24 | - | DC-10~+10 ~ DC5~24 | - | - | - | 24 | - | 5 | - | - | - | - | - | - | - | - | - | - | - | - |
Protection function | None / Input protection function / Output protection function | - | - | - | Output protection function | None | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
Connection Terminal | Terminal Block / Connector / Europe terminal block | - | - | Terminal Block / Connector | Terminal Block / Connector | Europe terminal block | - | - | Terminal block/connector | Terminal Block / Connector | Connector | Terminal Block / Connector | - | Connector | Terminal Block / Connector | Terminal Block | - | Terminal Block | Connector | Connector | Connector | - | - | - | Connector | Terminal Block | - |
Representative Standard | CUL | CUL | CUL | CUL | CUL | CUL | CUL | CUL | CUL | CUL | CUL | CUL | CUL | CUL | CUL | CUL | CUL | CUL | CUL | CUL | CUL | CUL | CUL | CUL | CUL | CUL | CUL |