(!)Due to Microsoft's end of support for Internet Explorer 11 on 15/06/2022, this site does not support the recommended environment.
Instead, please kindly use other browsers like Google Chrome, Microsoft Edge or Mozilla Firefox.
A wide variety of standard and configurable components for factory automation engineers in industries such as automotive, semiconductor, packaging, medical and many more.
A good selection of accessories such as screws, bolts, washers and nuts that you may need for your daily engineering usage.
Browse industrial materials ranging from heat insulating plates, sponges, to metal and plastic materials in different sizes to meet your various applications.
A wide variety of wiring parts for connecting and protecting control and PC parts including Connectors, Cables, Electric Wires, Crimping Terminals and more.
A wide variety of controls and PC parts for electrical engineers including Controls, Powers, PC parts and more.
A wide variety of cutting tools for many uses and work materials including End Mills, Drills, Cutters, Reamers, Turning Tools and more.
A wide variety of tools and supplies used in processing including Machine Tools, Measurement Tools, Grinding and Polishing Supplies and more.
A wide variety of goods used in shipment, material handling and warehouse including Tape supplies, Stretch film, Truck, Shelf, Crane and more.
A large variety of goods for every kind of factories and offices including Protection items, Cleaning supplies, sanitations, office supplies and more.
A large variety of items used in R&D and Clean Room including research Equipment, Laboratory Essentials, Analysis Supplies, Clean Environment-Related Equipment and more.
Choose from thousands of standard stamping die components including Punch & Die, Gas Springs, Guide Components, Coil Springs and many more.
Browse our wide variety of mold components including Ejector Pins, Sleeves, Leader Components, Sprue Bushings and many more.
Browse our injection molding components including Heating Items, Couplers, Hoses and more.
Connecting this reactor to the inverter input side improves the power factor and reduces the input-side harmonic current.
Part Number
Configured Part Number is shown.
FR-HEL-H250K
Format FR-HAL-[][] | 200 V | 400 V |
0.4K to 110K *1 | H0.4K to H560K *1 | |
Power factor improvement effect *2 | Power supply factor: approx. 88% (92.3%*3) at 100% load | |
Vibration | 5.9 m/s2 or less, 10 to 55 Hz (directions of X, Y, Z axes) | H110K or lower: 5.9 m/s2 or less H185K or higher: 2.9 m/s2 or less, 10 to 55 Hz (directions of X, Y, Z axes) |
Mounting Method | (H)55K or lower: Mount horizontally or vertically (H)75K or higher: Mount horizontally |
*1 See Format in Outline Drawing for capacity details.
*2 The power factor value assumes a power supply impedance of 1%. The power supply capacity value varies depending on the power supply impedance.
The load applies to a basic wave current of 100%, based on the JEM-TR201 standard. The power factor improvement effect will be slightly lower if using a motor of 0.4 kW or less.
*3 The power factor improvement effect is approx. 88% (92.3% when calculated assuming that the power factor of a basic wave is 1, based on the 2013 edition of the Public Building Construction Standard Specifications [Electrical Facilities Construction Edition] compiled by the Ministry of Land, Infrastructure, Transport and Tourism).
• This is a representative drawing of the external appearance. The actual external appearance will differ depending on the format.
& bull; W1 and D1 indicate the mounting hole pitch. D indicates the mounting hole size.
& bull; As the reactor itself will generate heat, be sure to secure sufficient space around the reactor.
(At least 10 cm above and below, and at least 5 cm on either side, regardless of the reactor mounting orientation)
Format | W | W1 | H | D | D1 | d | Weight (kg) | |
200 V | 0.4K | 104 | 84 | 99 | 72 | 40 | M5 | 0.6 |
0.75K | 104 | 84 | 99 | 74 | 44 | M5 | 0.8 | |
1.5K | 104 | 84 | 99 | 77 | 50 | M5 | 1.1 | |
2.2K | 115 | 40 | 115 | 77 | 57 | M6 | 1.5 | |
5.5K | 115 | 40 | 115 | 83 | 67 | M6 | 2.3 | |
7.5K | 130 | 50 | 135 | 100 | 86 | M6 | 4.2 | |
11K | 160 | 75 | 164 | 111 | 92 | M6 | 5.2 | |
15K | 160 | 75 | 167 | 126 | 107 | M6 | 7 | |
18.5K | 160 | 75 | 128 | 175 | 107 | M6 | 7.1 | |
22K | 185 | 75 | 150 | 158 | 87 | M6 | 9 | |
30K | 185 | 75 | 150 | 168 | 87 | M6 | 9.7 | |
37K | 210 | 75 | 175 | 174 | 82 | M6 | 12.9 | |
55K | 210 | 75 | 175 | 201 | 97 | M6 | 17.4 | |
75K | 240 | 150 | 210 | 213 | 109 | M8 | 23 | |
110K | 330 | 170 | 325 | 258 | 127 | M10 | 40 |
Format | W | W1 | H | D | D1 | d | Weight (kg) | |
400 V | H0.4K | 135 | 120 | 115 | 59.6 | 45 | M4 | 1.5 |
H1.5K | 135 | 120 | 115 | 59.6 | 45 | M4 | 1.5 | |
H2.2K | 135 | 120 | 115 | 59.6 | 45 | M4 | 1.5 | |
H3.7K | 135 | 120 | 115 | 70.6 | 57 | M4 | 2.5 | |
H5.5K | 160 | 145 | 142 | 72 | 55 | M4 | 3.5 | |
H7.5K | 160 | 145 | 142 | 91 | 75 | M4 | 5 | |
H11K | 160 | 145 | 146 | 91 | 75 | M4 | 6 | |
H15K | 220 | 200 | 195 | 105 | 70 | M5 | 9 | |
H18.5K | 220 | 200 | 215 | 170 | 70 | M5 | 9 | |
H22K | 220 | 200 | 215 | 170 | 70 | M5 | 9.5 | |
H30K | 220 | 200 | 215 | 170 | 75 | M5 | 11 | |
H37K | 220 | 200 | 214 | 170 | 100 | M5 | 12.5 | |
H45K | 280 | 255 | 245 | 165 | 80 | M6 | 15 | |
H55K | 280 | 255 | 245 | 170 | 90 | M6 | 18 | |
H110K | 240 | 150 | 225 | 220 | 99 | M8 | 28 | |
H185K | 330 | 170 | 325 | 270 | 142 | M10 | 55 | |
H280K | 330 | 170 | 325 | 320 | 192 | M10 | 80 | |
H355K | 330 | 170 | 325 | 340 | 192 | M10 | 80 |
Format FR-HEL-[][] | 200 V | 400 V |
0.4K to 110K *1 | H0.4K to H355K *1 | |
Power factor improvement effect *2 | Power supply factor: approx. 93% (94.4% *3) | |
Vibration | 5.9 m/s2 or less, 10 to 55 Hz (directions of X, Y, Z axes) | |
Mounting Method | Mount horizontally or vertically |
*1 See Format in Outline Drawing for capacity details.
*2 The power factor value assumes a power supply impedance of 1%. The power supply capacity value varies depending on the power supply impedance.
The load applies to a basic wave current of 100%, based on the JEM-TR201 standard. The power factor improvement effect will be slightly lower if using a motor of 0.4 kW or less.
*3 The power factor improvement effect is approx. 93% (94.4% when calculated assuming that the power factor of a basic wave is 1, based on the 2013 edition of the Public Building Construction Standard Specifications [Electrical Facilities Construction Edition] compiled by the Ministry of Land, Infrastructure, Transport and Tourism).
• This is a representative drawing of the external appearance. The actual external appearance will differ depending on the format.
& bull; W1 and D1 indicate the mounting hole pitch. D indicates the mounting hole size.
& bull; As the reactor itself will generate heat, be sure to secure sufficient space around the reactor.
(At least 10 cm above and below, and at least 5 cm on either side, regardless of the reactor mounting orientation)
Format | W | W1 | H | D | D1 | d | Weight (kg) | |
200 V | 2.2K | 85 | 74 | 81 | 70 | ─ | M4 | 0.9 |
5.5K | 77 | 55 | 92 | 92 | 67 | M4 | 1.9 | |
11K | 105 | 64 | 133 | 112 | 79 | M6 | 3.3 | |
15K | 105 | 64 | 133 | 115 | 84 | M6 | 4.1 | |
18.5K | 105 | 64 | 93 | 165 | 94 | M6 | 4.7 | |
30K | 114 | 72 | 100 | 200 | 101 | M6 | 7.8 | |
37K | 133 | 86 | 117 | 195 | 98 | M6 | 10 | |
45K | 133 | 86 | 117 | 205 | 108 | M6 | 11 | |
55K | 153 | 126 | 132 | 209 | 122 | M6 | 12.6 | |
75K | 150 | 130 | 190 | 340 | 310 | M6 | 17 | |
90K | 150 | 130 | 200 | 340 | 310 | M6 | 19 | |
110K | 175 | 150 | 200 | 400 | 365 | M8 | 20 |
Format | W | W1 | H | D | D1 | d | Weight (kg) | |
400 V | H0.4K | 90 | 75 | 78 | 60 | ─ | M5 | 0.6 |
H0.75K | 66 | 50 | 100 | 70 | 48 | M4 | 0.8 | |
H5.5K | 96 | 60 | 128 | 100 | 75 | M5 | 3 | |
H11K | 105 | 75 | 137 | 110 | 85 | M5 | 4.5 | |
H18.5K | 114 | 75 | 162 | 120 | 80 | M5 | 5 | |
H22K | 133 | 90 | 178 | 120 | 75 | M5 | 6 | |
H30K | 133 | 90 | 178 | 120 | 80 | M5 | 6.5 | |
H37K | 133 | 90 | 187 | 155 | 100 | M5 | 8.5 | |
H45K | 133 | 90 | 187 | 170 | 110 | M5 | 10 | |
H55K | 152 | 105 | 206 | 170 | 106 | M6 | 11.5 | |
H75K | 140 | 120 | 185 | 320 | 295 | M6 | 16 | |
H90K | 150 | 130 | 190 | 340 | 310 | M6 | 20 | |
H110K | 150 | 130 | 195 | 340 | 310 | M6 | 22 | |
H132K | 175 | 150 | 200 | 405 | 370 | M8 | 26 | |
H160K | 175 | 150 | 205 | 405 | 370 | M8 | 28 | |
H250K | 190 | 165 | 250 | 440 | 400 | M8 | 35 | |
H280K | 190 | 165 | 255 | 440 | 400 | M8 | 38 | |
H315K | 210 | 185 | 250 | 495 | 450 | M10 | 42 | |
H355K | 210 | 185 | 250 | 495 | 450 | M10 | 46 |
Part Number |
---|
FR-HEL-H250K |
Part Number | Standard Unit Price | Minimum order quantity | Volume Discount | Days to Ship | Type | Voltage class (V) | Applicable inverter capacity (kW) | Width (W) (mm) | Height (H) (mm) | Depth (D) (mm) | Weight (kg) | Protection class | CE Conformity | UL/cUL Conformity | UKCA Conformity | Dimension (W) (mm) | Dimension (D) (mm) | Dimension (H) (mm) |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
SGD 2,555.34 | 1 Piece(s) | Quote | DC Reactor | 400 | 250 | - | - | - | - | - | - | - | - | 190 | 440 | 250 |
Loading...
Compatible Series | FREQROL Series |
---|
Please check the type/dimensions/specifications of the part FR-HEL-H250K in the Optional Reactor For FREQROL series.
Part Number |
---|
FR-HAL-H110K |
FR-HAL-H185K |
FR-HAL-H280K |
FR-HEL-H280K |
FR-HEL-H315K |
FR-HEL-H355K |
Part Number | Standard Unit Price | Minimum order quantity | Volume Discount | Days to Ship | Type | Voltage class (V) | Applicable inverter capacity (kW) | Width (W) (mm) | Height (H) (mm) | Depth (D) (mm) | Weight (kg) | Protection class | CE Conformity | UL/cUL Conformity | UKCA Conformity | Dimension (W) (mm) | Dimension (D) (mm) | Dimension (H) (mm) |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
SGD 1,624.50 | 1 Piece(s) | Quote | AC Reactor | 400 | 110 | - | - | - | - | - | - | - | - | 240 | 220 | 225 | ||
SGD 2,210.34 | 1 Piece(s) | Quote | AC Reactor | 400 | 185 | - | - | - | - | - | - | - | - | 330 | 270 | 325 | ||
SGD 2,654.17 | 1 Piece(s) | Quote | AC Reactor | 400 | 280 | - | - | - | - | - | - | - | - | 330 | 320 | 325 | ||
SGD 2,815.84 | 1 Piece(s) | Quote | DC Reactor | 400 | 280 | - | - | - | - | - | - | - | - | 190 | 440 | 255 | ||
SGD 3,076.50 | 1 Piece(s) | Quote | DC Reactor | 400 | 315 | - | - | - | - | - | - | - | - | 210 | 495 | 250 | ||
SGD 3,885.17 | 1 Piece(s) | Quote | DC Reactor | 400 | 355 | - | - | - | - | - | - | - | - | 210 | 495 | 250 |