(!)Due to Microsoft's end of support for Internet Explorer 11 on 15/06/2022, this site does not support the recommended environment.
Instead, please kindly use other browsers like Google Chrome, Microsoft Edge or Mozilla Firefox.

  • Scheduled Maintenance Notice: This site will be unavailable due to scheduled maintenance from 9:00 24/11/2024 to 7:00 (SGT) 25/11/2024. We apologize for the inconvenience.
  • Notice of End of Sales for Economy Series Pneumatic Equipment Category. More information.

Optional Reactor For FREQROL (FR-HAL-110K)

Optional Reactor For FREQROL FR-HAL-110K

Connecting this reactor to the inverter input side improves the power factor and reduces the input-side harmonic current.

PDF

Part Number

Configured Part Number is shown.

FR-HAL-110K

AC Reactor

Specifications

Related image: FR-HAL
 
Format FR-HAL-[][] 200 V 400 V
0.4K to 110K *1 H0.4K to H560K *1
Power factor improvement effect *2 Power supply factor: approx. 88% (92.3%*3) at 100% load
Vibration 5.9 m/s2 or less,
10 to 55 Hz (directions of X, Y, Z axes)
H110K or lower: 5.9 m/s2 or less
H185K or higher: 2.9 m/s2 or less,
10 to 55 Hz (directions of X, Y, Z axes)
Mounting Method (H)55K or lower: Mount horizontally or vertically
(H)75K or higher: Mount horizontally

*1 See Format in Outline Drawing for capacity details.
*2 The power factor value assumes a power supply impedance of 1%. The power supply capacity value varies depending on the power supply impedance.
The load applies to a basic wave current of 100%, based on the JEM-TR201 standard. The power factor improvement effect will be slightly lower if using a motor of 0.4 kW or less.
*3 The power factor improvement effect is approx. 88% (92.3% when calculated assuming that the power factor of a basic wave is 1, based on the 2013 edition of the Public Building Construction Standard Specifications [Electrical Facilities Construction Edition] compiled by the Ministry of Land, Infrastructure, Transport and Tourism).

Dimensional Outline Drawing

• This is a representative drawing of the external appearance. The actual external appearance will differ depending on the format.
& bull; W1 and D1 indicate the mounting hole pitch. D indicates the mounting hole size.
& bull; As the reactor itself will generate heat, be sure to secure sufficient space around the reactor.
(At least 10 cm above and below, and at least 5 cm on either side, regardless of the reactor mounting orientation)

Related image: Dimensional Drawing
 
(Unit: mm)
Format W W1 H D D1 d Weight
(kg)
200 V 0.4K 104 84 99 72 40 M5 0.6
0.75K 104 84 99 74 44 M5 0.8
1.5K 104 84 99 77 50 M5 1.1
2.2K 115 40 115 77 57 M6 1.5
5.5K 115 40 115 83 67 M6 2.3
7.5K 130 50 135 100 86 M6 4.2
11K 160 75 164 111 92 M6 5.2
15K 160 75 167 126 107 M6 7
18.5K 160 75 128 175 107 M6 7.1
22K 185 75 150 158 87 M6 9
30K 185 75 150 168 87 M6 9.7
37K 210 75 175 174 82 M6 12.9
55K 210 75 175 201 97 M6 17.4
75K 240 150 210 213 109 M8 23
110K 330 170 325 258 127 M10 40
    
(Unit: mm)
Format W W1 H D D1 d Weight
(kg)
400 V H0.4K 135 120 115 59.6 45 M4 1.5
H1.5K 135 120 115 59.6 45 M4 1.5
H2.2K 135 120 115 59.6 45 M4 1.5
H3.7K 135 120 115 70.6 57 M4 2.5
H5.5K 160 145 142 72 55 M4 3.5
H7.5K 160 145 142 91 75 M4 5
H11K 160 145 146 91 75 M4 6
H15K 220 200 195 105 70 M5 9
H18.5K 220 200 215 170 70 M5 9
H22K 220 200 215 170 70 M5 9.5
H30K 220 200 215 170 75 M5 11
H37K 220 200 214 170 100 M5 12.5
H45K 280 255 245 165 80 M6 15
H55K 280 255 245 170 90 M6 18
H110K 240 150 225 220 99 M8 28
H185K 330 170 325 270 142 M10 55
H280K 330 170 325 320 192 M10 80
H355K 330 170 325 340 192 M10 80

DC Reactor

Specifications

Related image: FR-HAL
 
Format FR-HEL-[][] 200 V 400 V
0.4K to 110K *1 H0.4K to H355K *1
Power factor improvement effect *2 Power supply factor: approx. 93% (94.4% *3)
Vibration 5.9 m/s2 or less, 10 to 55 Hz (directions of X, Y, Z axes)
Mounting Method Mount horizontally or vertically

*1 See Format in Outline Drawing for capacity details.
*2 The power factor value assumes a power supply impedance of 1%. The power supply capacity value varies depending on the power supply impedance.
The load applies to a basic wave current of 100%, based on the JEM-TR201 standard. The power factor improvement effect will be slightly lower if using a motor of 0.4 kW or less.
*3 The power factor improvement effect is approx. 93% (94.4% when calculated assuming that the power factor of a basic wave is 1, based on the 2013 edition of the Public Building Construction Standard Specifications [Electrical Facilities Construction Edition] compiled by the Ministry of Land, Infrastructure, Transport and Tourism).

Dimensional Outline Drawing

• This is a representative drawing of the external appearance. The actual external appearance will differ depending on the format.
& bull; W1 and D1 indicate the mounting hole pitch. D indicates the mounting hole size.
& bull; As the reactor itself will generate heat, be sure to secure sufficient space around the reactor.
(At least 10 cm above and below, and at least 5 cm on either side, regardless of the reactor mounting orientation)

Related image: Dimensional Drawing
 
(Unit: mm)
Format W W1 H D D1 d Weight
(kg)
200 V 2.2K 85 74 81 70 M4 0.9
5.5K 77 55 92 92 67 M4 1.9
11K 105 64 133 112 79 M6 3.3
15K 105 64 133 115 84 M6 4.1
18.5K 105 64 93 165 94 M6 4.7
30K 114 72 100 200 101 M6 7.8
37K 133 86 117 195 98 M6 10
45K 133 86 117 205 108 M6 11
55K 153 126 132 209 122 M6 12.6
75K 150 130 190 340 310 M6 17
90K 150 130 200 340 310 M6 19
110K 175 150 200 400 365 M8 20
    
(Unit: mm)
Format W W1 H D D1 d Weight
(kg)
400 V H0.4K 90 75 78 60 M5 0.6
H0.75K 66 50 100 70 48 M4 0.8
H5.5K 96 60 128 100 75 M5 3
H11K 105 75 137 110 85 M5 4.5
H18.5K 114 75 162 120 80 M5 5
H22K 133 90 178 120 75 M5 6
H30K 133 90 178 120 80 M5 6.5
H37K 133 90 187 155 100 M5 8.5
H45K 133 90 187 170 110 M5 10
H55K 152 105 206 170 106 M6 11.5
H75K 140 120 185 320 295 M6 16
H90K 150 130 190 340 310 M6 20
H110K 150 130 195 340 310 M6 22
H132K 175 150 200 405 370 M8 26
H160K 175 150 205 405 370 M8 28
H250K 190 165 250 440 400 M8 35
H280K 190 165 255 440 400 M8 38
H315K 210 185 250 495 450 M10 42
H355K 210 185 250 495 450 M10 46
Part Number
FR-HAL-110K
Part NumberStandard Unit PriceMinimum order quantityVolume DiscountDays to ShipType Voltage class
(V)
Applicable inverter capacity
(kW)
Width (W)
(mm)
Height (H)
(mm)
Depth (D)
(mm)
Weight
(kg)
Protection class CE Conformity UL/cUL Conformity UKCA Conformity Dimension (W)
(mm)
Dimension (D)
(mm)
Dimension (H)
(mm)

SGD 1,624.50

1 Piece(s) Quote AC Reactor200110--------330258325

Loading...

  1. 1
 

Basic Information

Compatible Series FREQROL Series

Please check the type/dimensions/specifications of the part FR-HAL-110K in the Optional Reactor For FREQROL series.

Similar Part Numbers

Part Number
FR-HAL-55K
FR-HAL-75K
FR-HAL-H110K
FR-HAL-H185K
FR-HAL-H280K
FR-HAL-H355K
Part NumberStandard Unit PriceMinimum order quantityVolume DiscountDays to ShipType Voltage class
(V)
Applicable inverter capacity
(kW)
Width (W)
(mm)
Height (H)
(mm)
Depth (D)
(mm)
Weight
(kg)
Protection class CE Conformity UL/cUL Conformity UKCA Conformity Dimension (W)
(mm)
Dimension (D)
(mm)
Dimension (H)
(mm)

SGD 1,207.67

1 Piece(s) Quote AC Reactor20055--------210201175

SGD 1,257.84

1 Piece(s) Quote AC Reactor20075--------240213210

SGD 1,624.50

1 Piece(s) Quote AC Reactor400110--------240220225

SGD 2,210.34

1 Piece(s) Quote AC Reactor400185--------330270325

SGD 2,654.17

1 Piece(s) Quote AC Reactor400280--------330320325

SGD 3,969.50

1 Piece(s) Quote AC Reactor400355--------330340325

Tech Support

Factory Automation, Electronics, Tools, & MRO (Maintenance, Repair and Operations)
Tel:(65) 6733 7211 / FAX:(65) 6733 0211
9:00am - 6:00pm (Monday - Friday)