MP3 Network Monitor Signal Tower

MP3 Network Monitor Signal Tower

Click this image to zoom it.

Move the mouse over the image to zoom

  • MP3 Network Monitor Signal Tower
  • MP3 Network Monitor Signal Tower
  • MP3 Network Monitor Signal Tower
  • MP3 Network Monitor Signal Tower
  • MP3 Network Monitor Signal Tower
  • MP3 Network Monitor Signal Tower
  • MP3 Network Monitor Signal Tower
  • MP3 Network Monitor Signal Tower
  • MP3 Network Monitor Signal Tower
  • MP3 Network Monitor Signal Tower
  • MP3 Network Monitor Signal Tower
  • MP3 Network Monitor Signal Tower
  • MP3 Network Monitor Signal Tower
  • MP3 Network Monitor Signal Tower
  • MP3 Network Monitor Signal Tower
  • MP3 Network Monitor Signal Tower

Detects network abnormalities
Instantly notifies with light, sound and email

PDF

Part Number

Configured Part Number is shown.

NHP-3FV2-RYG

Network Monitor Signal Tower with MP3 Catalog, NH□-□FV2□-□□□□□  Click here


Details of the network monitoring indicator lights NHS-FV1/NHP-FV1/NHL-FV1

Network monitoring indicator NHS-FV1 product image
Network monitoring indicator NHS-FV1 product image
Network monitoring indicator NHP-FV1 product image
Network monitoring indicator NHP-FV1 product image
Network monitoring indicator NHL-FV1 product image
Network monitoring indicator NHL-FV1 product image


 

Network monitoring indicator NHS-FV1/NHP-FV1/NHL-FV1 specifications
 

NHS-FV1 Series

(Unit: mm)
NHS-FV1 series dimensional diagram
NHS-FV1 series dimensional diagram

 

Number of steps1st tier2nd grade3 levels4 levels5 levels
Body length (mm)198228258288318
Mass (g)940950960970980

 

 

 

 

 

 

 

 

 

 

Product Model

NHS-3FV1-RYG

network

Physical Layer

Ethernet (IEEE802.3 compliant) 10BASE-T/100BASE-TX (auto-negotiation, full-duplex/half-duplex)

Data Link Layer

CSMA/CD

Network Layer

IP, ICMP, ARP

Transport Layer

TCP/UDP

Application Layer

HTTP, SMTP, SNMP, RSH, NTP, POP, DNS, SOCKET, DHCP, SLMP

Other Features

Clear Switch

Yes (lights off and sound stopped)

Self-diagnosis function

can be

Number of steps

1 to 5 levels (can be changed after purchase)

Color sequence

Standard color (can be changed after purchase)

Configuration Features

Web Settings

Indicator Light Section

Emitting color

Red, yellow, green, blue, white (LED)
transparent globe

Number of flashes (cycle)

60 times/min

Sound pressure level (at1m/variable)

Maximum 88dB or more to 0

Sound Type

Voice/Buzzer

Audio Line Output

can be

Number of playback sounds

Up to 70 types

Buzzer sound

4 sounds (beep beep beep beep beep) (beep beep beep) (beep beep beep) (beep *continuous sound)

Playback Mode

Last input priority playback/Memory playback

Volume adjustment

Stepless adjustment by analog vol. / Input from web screen

BUSY output

can be

Specifications

power consumption

Main unit 2.2W

3.5W

Power supply

Dedicated AC adapter included (compliant with Japanese regulations)

Rated voltage

Main unit: DC24V / AC adapter: AC100V-240V

Operating temperature limit

0 to 40°C

Operating humidity range

20 to 80% RH or less (no condensation)

External Contact Output

1point

External Contact Input

4 points

USB port

TYPE-A 1 item

Operation section

Clear switch, reset switch, test switch, mode switch, volume

Compliance standards

CE marking compliance: EN55032, EN55024
FCC Part 15 Subpart B Class A



NHP-FV1 series/NHL-FV1 series

(Unit: mm)
NHP-FV1 series/NHL-FV1 series dimensional diagram
NHP-FV1 series/NHL-FV1 series dimensional diagram


Body length and weight of NHP-□FV1 type by number of stages

Number of steps1st tier2nd grade3 levels4 levels5 levels
Body length (mm)276311346381416
Mass (g)9801,0101,0401,0701,100


NHL-□FV1 type body length by number of stages

Number of steps1st tier2nd grade3 levels4 levels5 levels
Body length (mm)268309350391432
Mass (g)1,0501,1001,1501,2001,250

*Weight does not include AC adapter.
 

 

 

 

 

Product Model

NHP-□FV1-□□□

NHL-□FV1-□□□

network

Physical Layer

Ethernet (IEEE802.3 compliant) 10BASE-T/100BASE-TX (auto-negotiation, full-duplex/half-duplex)

Data Link Layer

CSMA/CD

Network Layer

IP, ICMP, ARP

Transport Layer

TCP/UDP

Application Layer

HTTP, SMTP, SNMP, RSH, NTP, POP, DNS, SOCKET, DHCP, SLMP

Other Features

Clear Switch

Yes (lights off and sound stopped)

Self-diagnosis function

can be

Number of steps

1 to 5 levels (can be changed after purchase)

Color sequence

Standard color (can be changed after purchase)

Configuration Features

Web Settings

Indicator Light Section

Emitting color

Red, yellow, green, blue, white (LED)
transparent globe

Number of flashes (cycle)

60 times/min

Sound pressure level (at1m/variable)

Maximum 88dB or more to 0

Sound Type

Voice/Buzzer

Audio Line Output

can be

Number of playback sounds

Up to 70 types

Buzzer sound

4 sounds (beep beep beep beep beep) (beep beep beep) (beep beep beep) (beep *continuous sound)

Playback Mode

Last input priority playback/Memory playback

Volume adjustment

Stepless adjustment by analog vol. / Input from web screen

BUSY output

can be

Specifications

power consumption

Main unit 2.2W

3.5W

Power supply

Dedicated AC adapter included (compliant with Japanese regulations)

Rated voltage

Main unit: DC24V / AC adapter: AC100V-240V

Operating temperature limit

0 to 40°C

Operating humidity range

20 to 80% RH or less (no condensation)

External Contact Output

1point

External Contact Input

4 points

USB port

TYPE-A 1 item

Operation section

Clear switch, reset switch, test switch, mode switch, volume

Compliance standards

FCC Part 15 Subpart B Class A

 

Part Number
NHP-3FV2-RYG
Part NumberStandard Unit PriceMinimum order quantityVolume DiscountDays to ShipRoHS

SGD 1,723.73

1 Piece(s) 7 Day(s) or more 10

Loading...

  1. 1
 

Basic Information

Type Standard Shape Round Thickness Ø40
Rated Voltage(V) DC24V Number of Steps 3 Color (top stage) Red
Color (second stage) Yellow Color (third stage) Green Light Source LED
Mounting Method Floor Mounting Buzzer (with/without) Available Lighting/blinking Lighting/blinking
Representative Standard PSE / CE / UL / CSA Body length 336 Self-diagnostic function Yes
JAN code 4938766021266 Note PSE: for included AC adapter only

Please check the type/dimensions/specifications of the part NHP-3FV2-RYG in the MP3 Network Monitor Signal Tower series.