NX Series Digital Output Unit NX-OD Transistor Output Unit (Part Numbers)

NX Series Digital Output Unit NX-OD Transistor Output Unit

Digital output unit that is available in many variations, from high-speed types that enable high-speed synchronization control to general-purpose types

■ Features
· Can be mounted on an EtherCAT coupler to enable high-speed I/O refreshing
· Enables I/O refreshing synchronized with the controller control period (synchronous refresh)
· Using this unit in combination with an NX Series CPU Unit or EtherCAT Coupler Unit, an NX unit that uses a time stamping input method,
and an NX unit that uses a time-specific output method enables highly precise I/O control that does not depend on the
controller's control period
· The use of a removable terminal block improves system maintainability
· The Push-In Plus terminal block (screwless clamp terminal block) and connector type (MIL connector / Fujitsu connector)
greatly reduce the time required for wiring work
· A unit width of only 12 mm realizes space saving (connector type 30 mm)
· 2-, 4-, 8-, 16- and 32-output-contact types are available, enabling the I/O configuration that best suits your equipment
· Connect to the CJ Series using the EtherNet/IP coupler

PDF

Part Number

Configured Part Number is shown.

 
Part Number
NX-OD3121
NX-OD3256
NX-OD4121
NX-OD4256
NX-OD5121
NX-OD5121-1
NX-OD5256
NX-OD5256-1
Part NumberStandard Unit PriceMinimum order quantityVolume DiscountDays to ShipRoHSNumber of Outputs Output Format Connection Terminal Output Voltage
(V)
Current Consumption
(A)
ON/OFF Response Time Short-circuit protection

SGD 134.17

1 Piece(s) 4 Day(s) or more 104[Other] Transistor Output / NPN[Terminal Block] Screwless Clamp Terminal12 to 24 DC10 mA or less0.1 ms or less / 0.8 ms or less-

SGD 134.17

1 Piece(s) 4 Day(s) or more 104[Other] Transistor Output / PNP[Terminal Block] Screwless Clamp Terminal24 DC20 mA or less0.5 ms or less / 1.0 ms or lessAvailable

SGD 146.70

1 Piece(s) Quote 108[Other] Transistor Output / NPN[Terminal Block] Screwless Clamp Terminal12 to 24 DC10 mA or less0.1 ms or less / 0.8 ms or less-

SGD 179.61

1 Piece(s) 4 Day(s) or more 108[Other] Transistor Output / PNP[Terminal Block] Screwless Clamp Terminal24 DC30 mA or less0.5 ms or less / 1.0 ms or lessAvailable

SGD 245.00

1 Piece(s) Quote 1016[Other] Transistor Output / NPN[Terminal Block] Screwless Clamp Terminal12 to 24 DC20 mA or less0.1 ms or less / 0.8 ms or less-

SGD 239.98

1 Piece(s) 4 Day(s) or more 1016[Other] Transistor Output / NPN[Terminal Block] Screw Terminal Block12 to 24 DC30 mA or less0.1 ms or less / 0.8 ms or less-

SGD 245.00

1 Piece(s) Quote 1016[Other] Transistor Output / PNP[Terminal Block] Screwless Clamp Terminal24 DC40 mA or less0.5 ms or less / 1.0 ms or lessAvailable

SGD 345.65

1 Piece(s) 4 Day(s) or more 1016[Other] Transistor Output / PNP[Terminal Block] Screw Terminal Block24 DC30 mA or less0.5 ms or less / 1.0 ms or lessAvailable

Loading...

  1. 1

Basic Information

Representative Standard CE / UL / CUL / CSA Output Current(A) 0.5 Name Digital Output Unit
I/O Refresh Method Switch between free-run and synchronous I/O