(!)Due to Microsoft's end of support for Internet Explorer 11 on 15/06/2022, this site does not support the recommended environment.
Instead, please kindly use other browsers like Google Chrome, Microsoft Edge or Mozilla Firefox.
A wide variety of standard and configurable components for factory automation engineers in industries such as automotive, semiconductor, packaging, medical and many more.
A good selection of accessories such as screws, bolts, washers and nuts that you may need for your daily engineering usage.
Browse industrial materials ranging from heat insulating plates, sponges, to metal and plastic materials in different sizes to meet your various applications.
A wide variety of wiring parts for connecting and protecting control and PC parts including Connectors, Cables, Electric Wires, Crimping Terminals and more.
A wide variety of controls and PC parts for electrical engineers including Controls, Powers, PC parts and more.
A wide variety of cutting tools for many uses and work materials including End Mills, Drills, Cutters, Reamers, Turning Tools and more.
A wide variety of tools and supplies used in processing including Machine Tools, Measurement Tools, Grinding and Polishing Supplies and more.
A wide variety of goods used in shipment, material handling and warehouse including Tape supplies, Stretch film, Truck, Shelf, Crane and more.
A large variety of goods for every kind of factories and offices including Protection items, Cleaning supplies, sanitations, office supplies and more.
A large variety of items used in R&D and Clean Room including research Equipment, Laboratory Essentials, Analysis Supplies, Clean Environment-Related Equipment and more.
Choose from thousands of standard stamping die components including Punch & Die, Gas Springs, Guide Components, Coil Springs and many more.
Browse our wide variety of mold components including Ejector Pins, Sleeves, Leader Components, Sprue Bushings and many more.
Browse our injection molding components including Heating Items, Couplers, Hoses and more.
- I/O module, iQ-R series from MITSUBISHI.
- Input/output rating is printed at the front, reducing incorrect wiring.
- Easy-to-use cable tie hook for tidy wiring.
- Existing 16-point terminal blocks are reusable, eliminating rewiring.
- Simple confirmation by product serial no. printed on the front.
- Alternating toggle switch used to display between 32-point LED signals.
- Terminal signals are clearly labeled and color-coded.
- Up to 32 LED signals clearly visible.
Part Number
Configured Part Number is shown.
RX40C7-TS
External appearance of RX40C7
RX40C7 dimensional drawing (unit: mm)
External appearance of RX10
Dimensional drawing of RX10 (Unit: mm)
Items | AV Input | DC input | |||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
RX28 | RX10 | RX10-TS | RX40C7 | RX40C7-TS | RX41C4 | RX41C4-TS | RX42C4 | RX70C4 | RX71C4 | RX72C4 | |
Number Of Points [Points] | 8 | 16 | 16 | 16 | 16 | 32 | 32 | 64 | 16 | 32 | 64 |
Rated Input Voltage, Frequency [V] | 100 to 240 V AC (50/60 Hz) | 100 to 240 V AC (50/60 Hz) | 100 to 240 V AC (50/60 Hz) | DC24 | DC24 | DC24 | DC24 | DC24 | DC5/12 | DC5/12 | DC5/12 |
Rated Input Current [mA] | 16.4 (200 V AC, 60 Hz) 13.7 (200 V AC, 50 Hz) 8.2 (100 V AC, 60 Hz) 6.8 (100 V AC, 50 Hz) | 8.2 (100 V AC, 60 Hz) 6.8 (100 V AC, 50 Hz) | 8.2 (100 V AC, 60 Hz) 6.8 (100 V AC, 50 Hz) | 7.0 TYP. | 7.0 TYP. | 4.0 TYP. | 4.0 TYP. | 4.0 TYP. | 1.7 (5 V DC) 4.8 (12 V DC) | 1.7 (5 V DC) 4.8 (12 V DC) | 1.7 (5 V DC) 4.8 (12 V DC) |
Response time | 20 ms or less | 20 ms or less | 20 ms or less | 0.1 to 70 ms | 0.1 to 70 ms | 0.1 to 70 ms | 0.1 to 70 ms | 0.1 to 70 ms | 0.1 to 70 ms | 0.1 to 70 ms | 0.1 to 70 ms |
Common Method [Point/Common] | 8 | 16 | 16 | 16 | 16 | 32 | 32 | 32 | 16 | 32 | 32 |
Interrupt Function | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● |
External wiring connection method^*1 | |||||||||||
18-Point Screw Terminal Block | ● | ● | — | ● | — | — | — | — | ● | — | — |
40-pin connector | — | — | — | — | — | ● | — | ● (× 2) | — | ● | ● (× 2) |
Items | DC High-Speed Input | Input With Self-Diagnosis Function | |||
---|---|---|---|---|---|
RX40PC6H | RX40NC6H | RX41C6HS | RX61C6HS | RX40NC6B | |
Number Of Points [Points] | 16 | 16 | 32 | 32 | 16 |
Rated Input Voltage, Frequency [V] | DC24 | DC24 | DC24 | DC5 | DC24 |
Rated Input Current [mA] | 6.0 | 6.0 | 6.0 | 6.0 | 6.0 |
Response time | 5 μs to 70 ms | 5 μs to 70 ms | 1 μs to 70 ms | 1 μs to 70 ms | 1 ms to 70 ms |
Common Method [Point/Common] | 8 (Positive common) | 8 (Negative common) | 32 (Positive/negative common) | 32 (Positive/negative common) | 16 (Negative common) |
Interrupt Function | ● | ● | ● | ● | ● |
Self-Diagnosis Function | |||||
Disconnection Detection Function | — | — | — | — | ● |
External wiring connection method^*1 | |||||
18-Point Screw Terminal Block | ● | ● | — | — | ● |
40-pin connector | — | — | ● | ● | — |
External appearance of RY20S6
Dimensional drawing of RY20S6 (Unit: mm)
External appearance of RY41PT2H
Dimensional drawing of RY41PT2H (Unit: mm)
Items | Relay output | Triac output | Transistor (Sink) Output | |||||||
---|---|---|---|---|---|---|---|---|---|---|
RY18R2A | RY10R2 | RY10R2-TS | RY20S6 | RY40NT5P | RY40NT5P-TS | RY41NT2P | RY41NT2P-TS | RY42NT2P | RY41NT2H | |
Number Of Points [Points] | 8 | 16 | 16 | 16 | 16 | 16 | 32 | 32 | 64 | 32 |
Rated Switch Voltage/Current | 24 V DC/2 A 240 V AC/2 A | 24 V DC/2 A 240 V AC/2 A | 24 V DC/2 A 240 V AC/2 A | AC100 to 240 V/0.6 A | — | — | — | — | — | — |
Rated Load Voltage [V] | — | — | — | — | DC12 to 24 | DC12 to 24 | DC12 to 24 | DC12 to 24 | DC12 to 24 | DC5 to 24 |
Maximum Load Current [A/Point] | — | — | — | — | 0.5 | 0.5 | 0.2 | 0.2 | 0.2 | 0.2 |
Response time | 12 ms or less | 12 ms or less | 12 ms or less | 1 ms + 0.5 cycle or less | 1 ms or less | 1 ms or less | 1 ms or less | 1 ms or less | 1 ms or less | 2 μs or less |
Common Method [Point/Common] | — | 16 | 16 | 16 | 16 | 16 | 32 | 32 | 32 | 32 |
Protection Function (Overload/Overheat) | — | — | — | — | ● | ● | ● | ● | ● | — |
External wiring connection method^*1 | ||||||||||
18-Point Screw Terminal Block | ● | ● | — | ● | ● | — | — | — | — | — |
40-pin connector | — | — | — | — | — | — | ● | — | ● (× 2) | ● |
Items | Transistor (Source) Output | Output With Self-Diagnosis Function (Source) | |||||
---|---|---|---|---|---|---|---|
RY40PT5P | RY40PT5P-TS | RY41PT1P | RY41PT1P-TS | RY42PT1P | RY41PT2H | RY40PT5B | |
Number Of Points [Points] | 16 | 16 | 32 | 32 | 64 | 32 | 16 |
Rated Load Voltage [V] | DC12 to 24 | DC12 to 24 | DC12 to 24 | DC12 to 24 | DC12 to 24 | DC5 to 24 | 24 V DC |
Maximum Load Current [A/Point] | 0.5 | 0.5 | 0.1 | 0.1 | 0.1 | 0.2 | 0.5 |
Response time | 1 ms or less | 1 ms or less | 1 ms or less | 1 ms or less | 1 ms or less | 2 μs or less | 1.5 ms or less |
Common Method [Point/Common] | 16 | 16 | 32 | 32 | 32 | 32 | 16 |
Protection Function (Overload/Overheat) | ● | ● | ● | ● | ● | — | ● |
Self-Diagnosis Function | |||||||
Output Disconnection Detection Function | — | — | — | — | — | — | ● |
Output Short-Circuit Detection Function | — | — | — | — | — | — | ● |
External wiring connection method^*1 | |||||||
18-Point Screw Terminal Block | ● | — | — | — | — | — | ● |
40-pin connector | — | — | ● | — | ● (× 2) | ● | — |
External appearance of RH42C4NT2P
Dimensional drawing of RH42C4NT2P (Unit: mm)
Items | RH42C4NT2P |
---|---|
DC input | |
Number Of Points [Points] | 32 |
Rated Input Voltage [V] | DC24 |
Rated Input Current [mA] | 4.0 TYP. |
Response time | 0.1 to 70 ms |
Common Method [Point/Common] | 32 |
Interrupt Function | ● |
Transistor (Sink) Output | |
Number Of Points [Points] | 32 |
Rated Load Voltage [V] | DC12 to 24 |
Maximum Load Current [A/Point] | 0.2 |
Response time | 1 ms or less |
Common Method [Point/Common] | 32 |
Protection Function (Overload/Overheat) | ● |
External wiring connection method^*1 | |
40-pin connector | ● (× 2) |
* External appearances and dimensional drawings provided here do not cover all models.
Part Number |
---|
RX40C7-TS |
Part Number | Standard Unit Price | Minimum order quantity | Volume Discount | Days to Ship | Number Of Inputs | Input Format | Rated Input Voltage (V) | Input answer time | Number of Outputs | Output Format | Rated load voltage (V) | Protection function | Connection Terminal | Representative Standard | Features | Output answer time | Terminal shape | Occupied I/O Points on PLC | Wiring | Int. Current Consumption (A) | Input Response Time Details |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
SGD 194.30 | 1 Piece(s) | Quote | 16 | DC input | DC24 | Less than 50 to 100 mS | - | - | - | None | Europe terminal block | CE / UL / CUL | - | - | Spring clamp terminal block | - | - | - | 0.1 to 70 mS |
Loading...
Please check the type/dimensions/specifications of the part RX40C7-TS in the iQ-R Series Input/Output Unit series.
Part Number |
---|
RX10-TS |
RX28 |
RX40C7 |
RX40NC6B |
RX40NC6H |
RX40PC6H |
Part Number | Standard Unit Price | Minimum order quantity | Volume Discount | Days to Ship | Number Of Inputs | Input Format | Rated Input Voltage (V) | Input answer time | Number of Outputs | Output Format | Rated load voltage (V) | Protection function | Connection Terminal | Representative Standard | Features | Output answer time | Terminal shape | Occupied I/O Points on PLC | Wiring | Int. Current Consumption (A) | Input Response Time Details |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
SGD 201.30 | 1 Piece(s) | 91 Day(s) | 16 | AC input | AC100 to 120 | Less than 10 to 20 mS | - | - | - | None | Europe terminal block | CE / CUL / UL | - | - | Spring clamp terminal block | - | - | - | 20 ms or less | ||
SGD 173.60 | 1 Piece(s) | 91 Day(s) | 8 | AC input | AC100 to 240 | Less than 10 to 20 mS | NA | - | - | None | Terminal Block | CE / CUL / UL | - | - | Terminal block | - | - | - | - | ||
SGD 166.60 | 1 Piece(s) | 20 Day(s) | 16 | DC input | DC24 | Less than 50 to 100 mS | NA | - | - | None | Terminal Block | CE / CUL / UL | - | - | Terminal block | - | - | - | - | ||
SGD 485.90 | 1 Piece(s) | Quote | 16 | DC input | DC24 | Less than 50 to 100 mS | NA | - | - | Input protection function | Terminal Block | CE / CUL / UL | Negative common | - | Connector | - | - | - | - | ||
SGD 236.10 | 1 Piece(s) | Quote | 16 | DC input | DC24 | Less than 50 to 100 mS | NA | - | - | None | Terminal Block | CE / CUL / UL | Negative common | - | Terminal block | - | - | - | - | ||
SGD 236.10 | 1 Piece(s) | Quote | 16 | DC input | DC24 | Less than 50 to 100 mS | NA | - | - | None | Terminal Block | CE / CUL / UL | Positive common | - | Terminal block | - | - | - | - |