MELSEC-F Input Expansion Board / Output Expansion Board

Part Number

Configured Part Number is shown.

FX3G-4EX-BD

MELSEC-F Input Expansion Board / Output Expansion Board Specifications

MELSEC-F Input Expansion Board: related image

FX3G-4EX-BD external appearance
Overview/input: 4 points
Approved standards: CE (EMC), KC

MELSEC-F Input Expansion Board: related image

FX3G-4EX-BD outline drawing
Unit: mm

MELSEC-F Input Expansion Board: related image

Input circuit configuration drawing of FX3G-4EX-BD (sink input)

*1. Service power supply of sequencer main body can be used.

MELSEC-F Input Expansion Board: related image

Input circuit configuration drawing of FX3G-4EX-BD (source input)

MELSEC-F Input Expansion Board: related image

FX3G-2EYT-BD external appearance
Overview/output: 2 points
Approved standards: CE (EMC), KC

MELSEC-F Input Expansion Board: related image

FX3G-2EYT-BD outline drawing
Unit: mm

MELSEC-F Input Expansion Board: related image

Output circuit configuration drawing of FX3G-2EYT-BD (sink)

MELSEC-F Input Expansion Board: related image

Output circuit configuration drawing of FX3G-2EYT-BD (source)

MELSEC-F Performance Specifications

FX3G-4EX-BD

Compatible SequencersFX3S (V1.10 or later), FX3G (V2.20 or later)
Power Supply Specification
Current Consumption5 V DCSupplied from the sequencer.
24 V DCSupply power from the external power supply at max. 25 mA.
Input Specification
Number Of Input Points4 points
Input Connection FormatEuropean Terminal Block
Input FormatSink/Source
Input Signal Voltage24 V DC +20%, - 15%
Input Impedance4.3 kΩ
Input Signal Current5 mA / 24 V DC
Input ON Sensing Current3.5 mA or more
Input OFF Sensing Current1.5 mA or less
Input Response TimeApprox. 10 ms
Input Signal FormatSink InputNon-voltage Contact
NPN Open Collector Transistor
Source InputNon-voltage Contact
PNP Open Collector Transistor
Input Circuit InsulationPhotocoupler Insulation
Input Operation IndicatorLED turns ON when photocoupler is operated.
 

FX3G-2EYT-BD

Compatible SequencersFX3S (V1.10 or later), FX3G (V2.20 or later)
Output Specification
Number Of Outputs2 points
Output Connection FormatEuropean Terminal Block
Output Type / FormatTransistor (sink/source)
External Power Supply5 to 30 V DC
Maximum LoadResistant Load0.5 A/point
Inductive Load12 W / 24 V DC
Leakage Current When Open0.1 mA / 30 V DC
ON Voltage1.5 V or less
Response TimeOFF→ON0.2 ms or less
ON→OFF0.2 ms or less
Circuit InsulationPhotocoupler Insulation
Output Operation IndicatorLED turns ON when photocoupler is operated.

MELSEC-F General Specifications

FX3G-4EX-BD

Ambient Temperature0 to 55°C - When Operating, -25 to 75°C - When Saving
Relative Humidity5 to 95% RH (no condensation) - when operating
Vibration ResistanceWhen Mounting
To DIN Rail
Frequency: 10 To 57 HzSingle amplitude: 0.035 mm 10 times in each direction of X, Y and Z (total 80 minutes each)
Judgment criteria are based on IEC61131-2.
Frequency: 57 To 150 HzAcceleration: 4.9 m/s2 10 times in each direction of X, Y and Z (total 80 minutes each)
Judgment criteria are based on IEC61131-2.
When Mounting DirectlyFrequency: 10 To 57 HzSingle amplitude: 0.075 mm 10 times in each direction of X, Y and Z (total 80 minutes each)
Judgment criteria are based on IEC61131-2.
Frequency: 57 To 150 HzAcceleration: 9.8 m/s2 10 times in each direction of X, Y and Z (total 80 minutes each)
Judgment criteria are based on IEC61131-2.
Impact Resistance147 m/s2, for a duration of 11 ms, 3 times in each direction of X, Y and Z with a half-sine pulse.
Judgment criteria are based on IEC61131-2.
Noise ResistanceJudged using a noise simulator with a noise voltage of 1,000 Vp-p, noise width of 1 μs, rise time of 1 ns, and frequency of 30 to 100 Hz.
Withstand VoltageBetween the input terminal of expansion output board and the earth terminal of base unit: 500 V AC for 1 minute
Insulation ResistanceBetween the input terminal of expansion output board and the earth terminal of base unit: 5 MΩ or more at 500 V DC on an insulation resistance meter
Operating AtmosphereThere shall be no corrosion gas or flammable gas and not much conductive dust.
Altitude Of Use2,000 m or lower
Cannot be used in environments pressurized higher than the atmospheric pressure. Doing so may cause failures.
 

FX3G-2EYT-BD

Ambient Temperature0 to 55°C - When Operating, -25 to 75°C - When Saving
Relative Humidity5 to 95% RH (no condensation) - when operating
Vibration ResistanceWhen Mounting
To DIN Rail
Frequency: 10 To 57 HzSingle amplitude: 0.035 mm 10 times in each direction of X, Y and Z (total 80 minutes each)
Judgment criteria are based on IEC61131-2.
Frequency: 57 To 150 HzAcceleration: 4.9 m/s2 10 times in each direction of X, Y and Z (total 80 minutes each)
Judgment criteria are based on IEC61131-2.
When Mounting DirectlyFrequency: 10 To 57 HzSingle amplitude: 0.075 mm 10 times in each direction of X, Y and Z (total 80 minutes each)
Judgment criteria are based on IEC61131-2.
Frequency: 57 To 150 HzAcceleration: 9.8 m/s2 10 times in each direction of X, Y and Z (total 80 minutes each)
Judgment criteria are based on IEC61131-2.
Impact Resistance147 m/s2, for a duration of 11 ms, 3 times in each direction of X, Y and Z with a half-sine pulse.
Judgment criteria are based on IEC61131-2.
Noise ResistanceJudged using a noise simulator with a noise voltage of 1,000 Vp-p, noise width of 1 μs, rise time of 1 ns, and frequency of 30 to 100 Hz.
Withstand VoltageBetween the output terminal of expansion output board and the earth terminal of base unit: 500 V AC for 1 minute
Insulation ResistanceBetween the output terminal of expansion output board and the earth terminal of base unit: 5 MΩ or more at 500 V DC on an insulation resistance meter
Operating AtmosphereThere shall be no corrosion gas or flammable gas and not much conductive dust.
Altitude Of Use2,000 m or lower
Cannot be used in environments pressurized higher than the atmospheric pressure. Doing so may cause failures.
Part Number
FX3G-4EX-BD
Part NumberStandard Unit PriceMinimum order quantityVolume DiscountDays to ShipNumber Of Inputs Rated Input Voltage
(V)
Number of Outputs Output Format Features Number Of Inputs
(Point)
Number of Outputs
(Point)
Type of unit

SGD 58.50

1 Piece(s) 91 Day(s) 4DC24VNA--4NAInput

Loading...

  1. 1
 

Basic Information

Representative Standard CE Applicable sequencer FX3G / FX3S

Please check the type/dimensions/specifications of the part FX3G-4EX-BD in the MELSEC-F Input Expansion Board / Output Expansion Board series.

Similar Part Numbers

Part Number
FX3G-2EYT-BD
Part NumberStandard Unit PriceMinimum order quantityVolume DiscountDays to ShipNumber Of Inputs Rated Input Voltage
(V)
Number of Outputs Output Format Features Number Of Inputs
(Point)
Number of Outputs
(Point)
Type of unit

SGD 52.20

1 Piece(s) 91 Day(s) NANot available2OtherTransistor output (sync / source)NA2Output