(!)Due to Microsoft's end of support for Internet Explorer 11 on 15/06/2022, this site does not support the recommended environment.
Instead, please kindly use other browsers like Google Chrome, Microsoft Edge or Mozilla Firefox.
A wide variety of standard and configurable components for factory automation engineers in industries such as automotive, semiconductor, packaging, medical and many more.
A good selection of accessories such as screws, bolts, washers and nuts that you may need for your daily engineering usage.
Browse industrial materials ranging from heat insulating plates, sponges, to metal and plastic materials in different sizes to meet your various applications.
A wide variety of wiring parts for connecting and protecting control and PC parts including Connectors, Cables, Electric Wires, Crimping Terminals and more.
A wide variety of controls and PC parts for electrical engineers including Controls, Powers, PC parts and more.
A wide variety of cutting tools for many uses and work materials including End Mills, Drills, Cutters, Reamers, Turning Tools and more.
A wide variety of tools and supplies used in processing including Machine Tools, Measurement Tools, Grinding and Polishing Supplies and more.
A wide variety of goods used in shipment, material handling and warehouse including Tape supplies, Stretch film, Truck, Shelf, Crane and more.
A large variety of goods for every kind of factories and offices including Protection items, Cleaning supplies, sanitations, office supplies and more.
A large variety of items used in R&D and Clean Room including research Equipment, Laboratory Essentials, Analysis Supplies, Clean Environment-Related Equipment and more.
Choose from thousands of standard stamping die components including Punch & Die, Gas Springs, Guide Components, Coil Springs and many more.
Browse our wide variety of mold components including Ejector Pins, Sleeves, Leader Components, Sprue Bushings and many more.
Browse our injection molding components including Heating Items, Couplers, Hoses and more.
Input expansion board for MELSEC-F Series.
Part Number
Configured Part Number is shown.
FX3G-4EX-BD external appearance
Overview/input: 4 points
Approved standards: CE (EMC), KC
FX3G-4EX-BD outline drawing
Unit: mm
Input circuit configuration drawing of FX3G-4EX-BD (sink input)
*1. Service power supply of sequencer main body can be used.
Input circuit configuration drawing of FX3G-4EX-BD (source input)
FX3G-2EYT-BD external appearance
Overview/output: 2 points
Approved standards: CE (EMC), KC
FX3G-2EYT-BD outline drawing
Unit: mm
Output circuit configuration drawing of FX3G-2EYT-BD (sink)
Output circuit configuration drawing of FX3G-2EYT-BD (source)
FX3G-4EX-BD
Compatible Sequencers | FX3S (V1.10 or later), FX3G (V2.20 or later) | |
---|---|---|
Power Supply Specification | ||
Current Consumption | 5 V DC | Supplied from the sequencer. |
24 V DC | Supply power from the external power supply at max. 25 mA. | |
Input Specification | ||
Number Of Input Points | 4 points | |
Input Connection Format | European Terminal Block | |
Input Format | Sink/Source | |
Input Signal Voltage | 24 V DC +20%, - 15% | |
Input Impedance | 4.3 kΩ | |
Input Signal Current | 5 mA / 24 V DC | |
Input ON Sensing Current | 3.5 mA or more | |
Input OFF Sensing Current | 1.5 mA or less | |
Input Response Time | Approx. 10 ms | |
Input Signal Format | Sink Input | Non-voltage Contact NPN Open Collector Transistor |
Source Input | Non-voltage Contact PNP Open Collector Transistor | |
Input Circuit Insulation | Photocoupler Insulation | |
Input Operation Indicator | LED turns ON when photocoupler is operated. |
FX3G-2EYT-BD
Compatible Sequencers | FX3S (V1.10 or later), FX3G (V2.20 or later) | |
---|---|---|
Output Specification | ||
Number Of Outputs | 2 points | |
Output Connection Format | European Terminal Block | |
Output Type / Format | Transistor (sink/source) | |
External Power Supply | 5 to 30 V DC | |
Maximum Load | Resistant Load | 0.5 A/point |
Inductive Load | 12 W / 24 V DC | |
Leakage Current When Open | 0.1 mA / 30 V DC | |
ON Voltage | 1.5 V or less | |
Response Time | OFF→ON | 0.2 ms or less |
ON→OFF | 0.2 ms or less | |
Circuit Insulation | Photocoupler Insulation | |
Output Operation Indicator | LED turns ON when photocoupler is operated. |
FX3G-4EX-BD
Ambient Temperature | 0 to 55°C - When Operating, -25 to 75°C - When Saving | ||
---|---|---|---|
Relative Humidity | 5 to 95% RH (no condensation) - when operating | ||
Vibration Resistance | When Mounting To DIN Rail | Frequency: 10 To 57 Hz | Single amplitude: 0.035 mm 10 times in each direction of X, Y and Z (total 80 minutes each) Judgment criteria are based on IEC61131-2. |
Frequency: 57 To 150 Hz | Acceleration: 4.9 m/s2 10 times in each direction of X, Y and Z (total 80 minutes each) Judgment criteria are based on IEC61131-2. | ||
When Mounting Directly | Frequency: 10 To 57 Hz | Single amplitude: 0.075 mm 10 times in each direction of X, Y and Z (total 80 minutes each) Judgment criteria are based on IEC61131-2. | |
Frequency: 57 To 150 Hz | Acceleration: 9.8 m/s2 10 times in each direction of X, Y and Z (total 80 minutes each) Judgment criteria are based on IEC61131-2. | ||
Impact Resistance | 147 m/s2, for a duration of 11 ms, 3 times in each direction of X, Y and Z with a half-sine pulse. Judgment criteria are based on IEC61131-2. | ||
Noise Resistance | Judged using a noise simulator with a noise voltage of 1,000 Vp-p, noise width of 1 μs, rise time of 1 ns, and frequency of 30 to 100 Hz. | ||
Withstand Voltage | Between the input terminal of expansion output board and the earth terminal of base unit: 500 V AC for 1 minute | ||
Insulation Resistance | Between the input terminal of expansion output board and the earth terminal of base unit: 5 MΩ or more at 500 V DC on an insulation resistance meter | ||
Operating Atmosphere | There shall be no corrosion gas or flammable gas and not much conductive dust. | ||
Altitude Of Use | 2,000 m or lower Cannot be used in environments pressurized higher than the atmospheric pressure. Doing so may cause failures. |
FX3G-2EYT-BD
Ambient Temperature | 0 to 55°C - When Operating, -25 to 75°C - When Saving | ||
---|---|---|---|
Relative Humidity | 5 to 95% RH (no condensation) - when operating | ||
Vibration Resistance | When Mounting To DIN Rail | Frequency: 10 To 57 Hz | Single amplitude: 0.035 mm 10 times in each direction of X, Y and Z (total 80 minutes each) Judgment criteria are based on IEC61131-2. |
Frequency: 57 To 150 Hz | Acceleration: 4.9 m/s2 10 times in each direction of X, Y and Z (total 80 minutes each) Judgment criteria are based on IEC61131-2. | ||
When Mounting Directly | Frequency: 10 To 57 Hz | Single amplitude: 0.075 mm 10 times in each direction of X, Y and Z (total 80 minutes each) Judgment criteria are based on IEC61131-2. | |
Frequency: 57 To 150 Hz | Acceleration: 9.8 m/s2 10 times in each direction of X, Y and Z (total 80 minutes each) Judgment criteria are based on IEC61131-2. | ||
Impact Resistance | 147 m/s2, for a duration of 11 ms, 3 times in each direction of X, Y and Z with a half-sine pulse. Judgment criteria are based on IEC61131-2. | ||
Noise Resistance | Judged using a noise simulator with a noise voltage of 1,000 Vp-p, noise width of 1 μs, rise time of 1 ns, and frequency of 30 to 100 Hz. | ||
Withstand Voltage | Between the output terminal of expansion output board and the earth terminal of base unit: 500 V AC for 1 minute | ||
Insulation Resistance | Between the output terminal of expansion output board and the earth terminal of base unit: 5 MΩ or more at 500 V DC on an insulation resistance meter | ||
Operating Atmosphere | There shall be no corrosion gas or flammable gas and not much conductive dust. | ||
Altitude Of Use | 2,000 m or lower Cannot be used in environments pressurized higher than the atmospheric pressure. Doing so may cause failures. |
Part Number |
---|
FX3G-2EYT-BD |
FX3G-4EX-BD |
Part Number | Standard Unit Price | Minimum order quantity | Volume Discount | Days to Ship | Number Of Inputs | Rated Input Voltage (V) | Number of Outputs | Output Format | Features | Number Of Inputs (Point) | Number of Outputs (Point) | Type of unit |
---|---|---|---|---|---|---|---|---|---|---|---|---|
SGD 52.20 | 1 Piece(s) | 91 Day(s) | NA | Not available | 2 | Other | Transistor output (sync / source) | NA | 2 | Output | ||
SGD 58.50 | 1 Piece(s) | 91 Day(s) | 4 | DC24V | NA | - | - | 4 | NA | Input |
Loading...
Representative Standard | CE | Applicable sequencer | FX3G / FX3S |
---|
How can we improve?