(!)Due to Microsoft's end of support for Internet Explorer 11 on 15/06/2022, this site does not support the recommended environment.
Instead, please kindly use other browsers like Google Chrome, Microsoft Edge or Mozilla Firefox.
A wide variety of standard and configurable components for factory automation engineers in industries such as automotive, semiconductor, packaging, medical and many more.
A good selection of accessories such as screws, bolts, washers and nuts that you may need for your daily engineering usage.
Browse industrial materials ranging from heat insulating plates, sponges, to metal and plastic materials in different sizes to meet your various applications.
A wide variety of wiring parts for connecting and protecting control and PC parts including Connectors, Cables, Electric Wires, Crimping Terminals and more.
A wide variety of controls and PC parts for electrical engineers including Controls, Powers, PC parts and more.
A wide variety of cutting tools for many uses and work materials including End Mills, Drills, Cutters, Reamers, Turning Tools and more.
A wide variety of tools and supplies used in processing including Machine Tools, Measurement Tools, Grinding and Polishing Supplies and more.
A wide variety of goods used in shipment, material handling and warehouse including Tape supplies, Stretch film, Truck, Shelf, Crane and more.
A large variety of goods for every kind of factories and offices including Protection items, Cleaning supplies, sanitations, office supplies and more.
A large variety of items used in R&D and Clean Room including research Equipment, Laboratory Essentials, Analysis Supplies, Clean Environment-Related Equipment and more.
Choose from thousands of standard stamping die components including Punch & Die, Gas Springs, Guide Components, Coil Springs and many more.
Browse our wide variety of mold components including Ejector Pins, Sleeves, Leader Components, Sprue Bushings and many more.
Browse our injection molding components including Heating Items, Couplers, Hoses and more.
A MELSEC-F Series special adapter for RS-232C communication.
Part Number
Configured Part Number is shown.
RS-232C Special Adapter for Communication (MODBUS compatible)
Overview: RS-232C communication (MODBUS compatible)
Compliant standards: CE (EMC), UL/cUL, KC, ABS, DNV, GL, LR, BV, RINA, NK, KR
When connected to an FX3 series unit, this adapter lets it function as a MODBUS communication master station or slave station to connect to various MODBUS communication device.
It can also be used as a nonprocedural communication, computer link or programming communication device.
FX3U-232ADP-MB external appearance
FX3U-232ADP-MB drawing
Unit: mm
RS-485 Special Adapter for Communication (MODBUS compatible)
Overview: RS-485 communication (MODBUS compatible)
Compliant standards: CE (EMC), UL/cUL, KC, ABS, DNV, GL, LR, BV, RINA, NK, KR
When connected to an FX3 series unit, this adapter lets it function as a MODBUS communication master station or slave station to connect to various MODBUS communication device.
It can also be used as a nonprocedural communication, computer link, parallel link, simple PC-PC link or inverter communication device.
FX3U-485ADP-MB external appearance
FX3U-485ADP-MB drawing
Unit: mm
RS-232C Communication Expansion Adapter
Overview: D-Sub 9-pin type, RS-232C communication
Compliant standards: CE (EMC), UL/cUL, KC, ABS, DNV, GL, LR, BV, RINA, NK, KR
RS-232C communication expansion adapter with D-sub 9-pin connector.
Insulated signal exchange unit that communicates serial data with RS-232C devices via the RS232C protocol.
FX5-232ADP external appearance
FX5-232ADP drawing
Unit: mm
RS-485 Communication Expansion Adapter
Overview: European terminal block type, RS-485 communication
Compliant standards: CE (EMC), UL/cUL, KC, ABS, DNV, GL, LR, BV, RINA, NK, KR
RS-485 communication expansion adapter having a European terminal block.
Insulated signal exchange unit for connecting devices having an RS-485 interface.
FX5-485ADP external appearance
FX5-485ADP drawing
Unit: mm
Process CPU unit R16PCPU
Overview:
Number of input/output points: 4,096 points
Program Capacity: 160 K steps
Basic command processing time (LDX0): 0.98 ns
Program memory capacity: 640 K bytes
Peripheral connection port: USB, Ethernet
Compliant standards: UL/cUL, CE (EMC), KC
R16PCPU external appearance
R16PCPU drawing
Unit: mm
FX3U-232ADP-MB
Transmission Standards | RS-232C compliant | |
---|---|---|
Insulation Method | Opto-isolator insulation | |
Transmitting Distance | Maximum 15 m | |
External Device Connection Method | D-SUB 9-pin connector (male) | |
Communication Method | Bi-directional full-duplex | |
Communication Procedure | · MODBUS communication (master or slave) · Nonprocedural communication · Computer link (dedicated protocol type 1, dedicated protocol type 4) · Programming communication | |
Communication Speed | MODBUS Communication | 300/600/1,200/2,400/4,800/9,600/19,200/38,400/57,600/115,200 (bps) 38,400/57,600/115,200 bps are supported by products manufactured in or after July 2012. (Serial number: 127**** or later) |
Nonprocedural Communication, Computer Link | 300/600/1,200/2,400/4,800/9,600/19,200/38,400 (bps) The FX3U and FX3UC Series support 38,400 bps effective from Ver. 2.41. | |
Programming Communication | 9,600/19,200/38,400/57,600/115,200 (bps) | |
Display (LED) | RD, SD, POWER | |
Number of Occupied Inputs/Outputs | 0 point (This has nothing to do with the maximum number of input/output points of the sequencer) | |
Applicable Sequencers | [FX3S] V1.00 or later: All communication functions are supported [FX3G] V1.00 or later: Communication functions other than MODBUS communication are supported V1.30 or later: MODBUS communication function is supported [FX3U] V2.20 or later: Communication functions other than MODBUS communication are supported V2.40 or later: MODBUS communication function is supported [FX3GC] V1.40 or later: All communication functions are supported [FX3UC] V1.00 or later: Communication functions other than MODBUS communication are supported V2.40 or later: MODBUS communication function is supported The FX3S-CNV-ADP is needed to connect to an FX3S. FX3G-CNV-ADP is required to connect to the FX3G. A function expansion board is required to connect to an FX3U or FX3UC-32MT-LT (-2). | |
Weight | 0.08 kg | |
Power Supply Specifications | ||
Power Supply | 5 V DC, 30 mA (internal power supply from sequencer) |
FX3U-485ADP-MB
Transmission Standards | Compliant with the RS-485 standard and RS-422 standard | |
---|---|---|
Insulation Method | Opto-isolator insulation | |
Transmitting Distance | Total extension length 500 m or less (If the device to be connected includes FX2N-485-BD, FX1N-485-BD, FX3U-485-BD or FX3G-485-BD, the total extension length is 50 ms or less) | |
External Device Connection Method | European Terminal Block | |
Communication Method | Bidirectional half-duplex | |
Communication Procedure | · MODBUS (master or slave) · Nonprocedural communication · Computer link (dedicated protocol type 1, dedicated protocol type 4) · Parallel link · Simple PC-PC link · Inverter communication | |
Communication Speed | MODBUS Communication | 300/600/1,200/2,400/4,800/9,600/19,200/38,400/57,600/115,200 (bps) 38,400/57,600/115,200 bps are supported by products manufactured in or after July 2012. (Serial number: 127**** or later) |
Nonprocedural, Computer Link | 300/600/1,200/2,400/4,800/9,600/19,200/38,400 (bps) The FX3U and FX3UC Series support 38,400 bps effective from Ver. 2.41. | |
Parallel Link | 115,200 (bps) | |
Simple PC to PC Link | 38,400 (bps) | |
Inverter Communication | 4,800/9,600/19,200/38,400 (bps) The FX3U and FX3UC Series support 38,400 bps effective from Ver. 2.41. | |
Display (LED) | RD, SD, POWER | |
Number of Occupied Inputs/Outputs | 0 point (This has nothing to do with the maximum number of input/output points of the sequencer) | |
Applicable Sequencers | [FX3S] V1.00 or later: All communication functions are supported [FX3G] V1.00 or later: Communication functions other than MODBUS and inverter communications are supported V1.10 or later: Inverter communication function is supported V1.30 or later: MODBUS communication function is supported [FX3U] V2.20 or later: Communication functions other than MODBUS communication are supported V2.40 or later: MODBUS communication function is supported [FX3GC] V1.40 or later: All communication functions are supported [FX3UC] V1.00 or later: Communication functions other than MODBUS communication are supported V2.40 or later: MODBUS communication function is supported FX3S-CNV-ADP is needed to connect to FX3S. FX3G-CNV-ADP is required to connect to the FX3G. A function expansion board is required to connect to an FX3U or FX3UC-32MT-LT (-2). | |
Weight | 0.08 kg | |
Power Supply Specifications | ||
Power Supply | 5 V DC, 20 mA (internal power supply from sequencer) |
FX5-232ADP
Transmission Standards | RS-232C standard-compliant | ||
---|---|---|---|
External Device Connection Method | D-sub 9-pin (male) | ||
Insulation | Opto-isolator insulation (between the communication line and the CPU) | ||
Communication Function | MC Protocol Function | Maximum Total Extension Distance | 15 m or less |
Protocol Format | MC protocol (dedicated protocol), 3C/4C frame Type 1 / type 4 / type 5 are available. | ||
Communication Method | Bidirectional half-duplex | ||
Baud Rate | 300/600/1,200/2,400/4,800/9,600/19,200/38,400/57,600/115,200 (bps) | ||
Nonprocedural Communication Function | Maximum Total Extension Distance | 15 m or less | |
Control Procedure | Nonprocedural Communication | ||
Communication Method | Bidirectional half-duplex / Bidirectional full-duplex | ||
Baud Rate | 300/600/1,200/2,400/4,800/9,600/19,200/38,400/57,600/115,200 (bps) | ||
Communication Protocol Support Function | Maximum Total Extension Distance | 15 m or less | |
Protocol Format | Communication Protocol Support | ||
Communication Method | Bidirectional half-duplex | ||
Baud Rate | 9,600/19,200/38,400/57,600/115,200 (bps) | ||
MODBUS Communication Function | Transmitting Distance | 15 m or less | |
Communication Protocol | RTU | ||
Baud Rate | 300/600/1,200/2,400/4,800/9,600/19,200/38,400/57,600/115,200 (bps) | ||
Compatible CPU Units | FX5U CPU unit: Ver. 1.000 onward (from the first unit) FX5UC CPU unit: Ver. 1.010 onward (from the first unit) | ||
Weight | Approx. 80 g | ||
Power Supply Specifications | |||
Rated Voltage (Internal Power Supply) | 5 V DC 24 V DC | ||
Current Consumption (Internal Power Supply) | 30 mA / 5 V DC 30 mA / 24 V DC |
FX5-485ADP
Transmission Standards | Compliant with the RS-485 and RS-422 standards | ||
---|---|---|---|
External Device Connection Method | European Terminal Block | ||
Terminating Resistor | Built-in (OPEN / 110Ω/ 330Ω) | ||
Insulation | Opto-isolator insulation (between the communication line and the CPU) | ||
Communication Function | Simple PC-PC Link Function | Maximum Total Extension Distance | 1,200 m or less when the system consists only of FX5-485ADP units 500 m or less when the system consists of FX5-485ADP and FX3U-485ADP units 50 m or less in other cases |
Protocol Format | Simple PC to PC link | ||
Communication Method | Bidirectional half-duplex | ||
Baud Rate | 38,400 (bps) | ||
MC Protocol Function | Maximum Total Extension Distance | FX5-485ADP is used: 1,200 m or less Built-in RS-485 port or FX5-485-BD is used: 50 m or less | |
Protocol Format | MC protocol (dedicated protocol), 3C/4C frame Type 1 / type 4 / type 5 are available. | ||
Communication Method | Bidirectional half-duplex | ||
Baud Rate | 300/600/1,200/2,400/4,800/9,600/19,200/38,400/57,600/115,200 (bps) | ||
Inverter Communication Function | Maximum Total Extension Distance | 1,200 m or less | |
Protocol Format | Inverter computer link | ||
Control Procedure | Asynchronous | ||
Communication Method | Bidirectional half-duplex | ||
Baud Rate | 4,800/9,600/19,200/38,400/57,600/115,200 (bps) 57,600 (bps) and higher rates are supported only by the FREQROL-A800 | ||
Nonprocedural Communication Function | Maximum Total Extension Distance | 1,200 m or less | |
Control Procedure | Nonprocedural Communication | ||
Communication Method | Bidirectional half-duplex / Bidirectional full-duplex | ||
Baud Rate | 300/600/1,200/2,400/4,800/9,600/19,200/38,400/57,600/115,200 (bps) | ||
Communication Protocol Support Function | Maximum Total Extension Distance | 1,200 m or less | |
Protocol Format | Communication Protocol Support | ||
Communication Method | Bidirectional half-duplex | ||
Baud Rate | 9,600/19,200/38,400/57,600/115,200 (bps) | ||
MODBUS Communication Function | Transmitting Distance | 1,200 m or less when the system consists only of FX5-485ADP units 50 m or less in other cases | |
Communication Protocol | RTU | ||
Baud Rate | 300/600/1,200/2,400/4,800/9,600/19,200/38,400/57,600/115,200 (bps) | ||
Compatible CPU Units | FX5U CPU unit: Ver. 1.000 onward (from the first unit) FX5UC CPU unit: Ver. 1.010 onward (from the first unit) | ||
Weight | Approx. 80 g | ||
Power Supply Specifications | |||
Rated Voltage (Internal Power Supply) | 5 V DC 24 V DC | ||
Current Consumption (Internal Power Supply) | 20 mA / 5 V DC 30 mA / 24 V DC |
Part Number |
---|
FX3U-485ADP-MB-DEL1 |
FX5-485ADP |
Part Number | Standard Unit Price | Minimum order quantity | Volume Discount | Days to Ship | Communication Interface (Transmission Standard) | Connection Terminal | Type of unit |
---|---|---|---|---|---|---|---|
- | 1 Piece(s) | Quote | RS-422/485 | Terminal Block | RS-485 communication (MODBUS compatible) | ||
SGD 118.10 | 1 Piece(s) | 91 Day(s) | RS-422/485 | Terminal Block | RS-485 communication expansion adapter |
Loading...
Representative Standard | CE / UL / CUL |
---|
How can we improve?
How can we improve?