L Series Temperature Adjustment Unit

Example Of L Series Temperature Adjustment Unit Specifications

L60TCRT4

L60TCRT4 image

L60TCRT4 image

L60TCRT4 Performance Specifications

Control OutputTransistor Output
Number Of Temperature Input Points4 channel/unit
Compatible Temperature Measuring ResistorsPt100, JPt100
AccuracyIndication AccuracyAmbient Temperature: 25±5°CFull scale × (±0.3%)
Ambient Temperature: 0 To 55°CFull Scale × (±0.7%)
Sampling Cycle250 ms / 4 channels, 500 ms / 4 channels
Control Output Period0.5 to 100 s
Input Impedance1 MΩ
Input Filter0 to 100 s (0: input filter OFF)
Setting Of Sensor Correction Value-50.00 to 50.00%
Operation In Case Of Sensor Input DisconnectionUpscale processing
Temperature Control SystemPID ON/OFF pulse or 2‑position control
PID Constant RangePID Constant SettingSetting by auto-tuning is possible.
Proportional Band (P)0.0 to 1,000.0% (0.0: 2‑position control)
Integral Time (I)0 to 3,600 s (0: P control, PD control)
Derivative Time (D)0 to 3,600 s (0: P control, PI control)
Target Value Setting RangeWithin the temperature range set by the platinum temperature measuring resistor used.
Dead Zone Setting Range0.1 to 10.0%
Transistor OutputOutput SignalON/OFF Pulse
Rated Load Voltage10 to 30 V DC
Max Load Current0.1 A/point, 0.4 A/common
Maximum Inrush Current0.4 A, 10 ms
Leak Current When OFF0.1 mA or less
Maximum Voltage Drop At ON1.0 V DC (TYP.) at 0.1 A, 2.5 V DC (MAX.) at 0.1 A
Response TimeOFF → ON2 ms or less
ON → OFF2 ms or less
Isolation MethodBetween input terminal and sequencer power supply, between input channels: transformer insulation
Dielectric StrengthBetween input terminal and sequencer power supply, between input channels: 500 V AC for 1 min
Insulation ResistanceBetween input terminal and sequencer power supply, between input channels: 20 mΩ or more at 500 V DC
External Wiring Connection Method18‑point terminal block (M3 screw)
Number Of Occupied Inputs/Outputs16 points (I/O assignment: intelligent 16 points)
5 V DC Internal Current Consumption0.31 A
External DimensionsHeight (H)90 mm
Width (W)28.5 mm
Depth (D)117 mm
Mass0.18 kg
  • * See the catalog for model numbers other than those detailed above.
Part Number
L60TCRT4
L60TCRT4BW
L60TCTT4
L60TCTT4BW
Part NumberStandard Unit PriceMinimum order quantityVolume DiscountDays to Ship

-

1 Piece(s) Quote

-

1 Piece(s) Quote

-

1 Piece(s) Quote

-

1 Piece(s) Quote

Loading...

  1. 1
 

Basic Information

Communication Interface (Transmission Standard) Other Representative Standard CE / UL / CUL

Tech Support

Factory Automation, Electronics, Tools, & MRO (Maintenance, Repair and Operations)
Tel:(65) 6733 7211 / FAX:(65) 6733 0211
9:00am - 6:00pm (Monday - Friday)