L Series AnyWireASLINK Master Unit

Example Of L Series AnyWireASLINK Master Unit Specifications

LJ51AW12AL

LJ51AW12AL image

LJ51AW12AL image

LJ51AW12AL Performance Specifications

Transmission Clock27.0 kHz
Maximum Transmission Distance (Total Extension)200 m
Number Of Connected UnitsMaximum 128 units (Varies depending on the current consumption of each slave unit.)
Transmission MethodDC power supply superimposed total frame / cyclic method
Connection FormBus type (multi-drop method, T-branching method, tree-branching method)
Transmission ProtocolDedicated protocol (AnyWireASLINK)
Error Control MethodChecksum, double verification method
Number Of Connected I/O PointsMaximum 512 points (256 input points / 256 output points)
AnyWireASLINK Transmission Wire· UL-compliant general-purpose 2‑wire cable (VCTF, VCT 1.25 mm2, 0.75 mm2, rated temperature 70°C or above)
· UL-compliant general-purpose wire (1.25 mm2, 0.75 mm2, rated temperature 70°C or above)
· Dedicated flat cable (1.25 mm2, 0.75 mm2, rated temperature 90°C)
24 V DC Power Line· UL-compliant general-purpose 2‑wire cable (VCTF, VCT 0.75 to 2.0 mm2, rated temperature 70°C or above)
· UL-compliant general-purpose wire (0.75 to 2.0 mm2, rated temperature 70°C or above)
· Dedicated flat cable (0.75 mm2, rated temperature 90°C)
External Power SupplyVoltage21.6 to 27.6 V DC (24 V DC, -10 to +15%), ripple voltage 0.5 Vp-p or less
Recommended voltage: 26.4 V (24 V DC, +10%)
Current0.1 A
Transmission Wire Supply CurrentWhen using 1.25 mm2 cable: max. 2 A
When using 0.75 mm2 cable: max. 1.2 A
Number Of Occupied Inputs/Outputs32 Points (I/O Assignment: Intelligent 32 Points)
5 V DC Internal Current Consumption0.20 A
External DimensionsHeight (H)90 mm
Width (W)28.5 mm
Depth (D)104.5 mm
Mass0.2 kg
Part Number
LJ51AW12AL
LJ51AW12D2
Part NumberStandard Unit PriceMinimum order quantityVolume DiscountDays to Ship

-

1 Piece(s) Quote

-

1 Piece(s) Quote

Loading...

  1. 1

Basic Information

Communication Interface (Transmission Standard) Other Representative Standard CE / UL / CUL

Tech Support

Factory Automation, Electronics, Tools, & MRO (Maintenance, Repair and Operations)
Tel:(65) 6733 7211 / FAX:(65) 6733 0211
9:00am - 6:00pm (Monday - Friday)