(!)Due to Microsoft's end of support for Internet Explorer 11 on 15/06/2022, this site does not support the recommended environment.
Instead, please kindly use other browsers like Google Chrome, Microsoft Edge or Mozilla Firefox.

  • Scheduled Maintenance Notice: This site will be unavailable due to scheduled maintenance from 9:00 24/11/2024 to 7:00 (SGT) 25/11/2024. We apologize for the inconvenience.
  • Notice of End of Sales for Economy Series Pneumatic Equipment Category. More information.

Chain Flex CF211- Twisted Pair Cable, with Shield (Part Numbers)

Chain Flex CF211- Twisted Pair Cable, with Shield

Features
● Supports high loads
● PVC jacketing
● Oil resistant
● Flame retardant

Application
● Intended for indoor use, but may be used outdoors in environments with temperatures of 5°C or more
● Particularly suited to free-span travel and sliding travel (maximum length 100 m)
● Ideal for automated warehouse management and delivery systems, machine tools, packaging machinery, material handling equipment, and indoor cranes, etc.

PDF

Japanese Only

Part Number

Configured Part Number is shown.

 
Part Number
CF211.05.04.02-0.5SQ-(4X2)-81
CF211.05.04.02-0.5SQ-(4X2)-82
CF211.05.04.02-0.5SQ-(4X2)-83
CF211.05.04.02-0.5SQ-(4X2)-84
CF211.05.04.02-0.5SQ-(4X2)-85
CF211.05.04.02-0.5SQ-(4X2)-86
CF211.05.04.02-0.5SQ-(4X2)-87
CF211.05.04.02-0.5SQ-(4X2)-88
CF211.05.04.02-0.5SQ-(4X2)-89
CF211.05.04.02-0.5SQ-(4X2)-90
CF211.05.04.02-0.5SQ-(4X2)-91
CF211.05.04.02-0.5SQ-(4X2)-92
CF211.05.04.02-0.5SQ-(4X2)-93
CF211.05.04.02-0.5SQ-(4X2)-94
CF211.05.04.02-0.5SQ-(4X2)-95
CF211.05.04.02-0.5SQ-(4X2)-96
CF211.05.04.02-0.5SQ-(4X2)-97
CF211.05.04.02-0.5SQ-(4X2)-98
CF211.05.04.02-0.5SQ-(4X2)-99
CF211.05.04.02-0.5SQ-(4X2)-100
Part NumberStandard Unit PriceMinimum order quantityVolume DiscountDays to ShipRoHSOverall Length
(m)
Conductor Cross Section
(mm2)
Number Of Cores
(Core)
Logarithm Finished outer diameter
(mm)
Minimum bending radius while running
(mm)
Minimum bending radius when fixed
(mm)
Conductor resistance
(Ω/km)
Reference allowable current value (30°C)
(A)
Note 1

SGD 1,241.00

1 Piece(s) 6 Day(s) or more 10810.584P9.571.2547.5395.5Rated voltage: Uo/U (V) Uo = Voltage between conductor and ground, U = voltage between conductors

SGD 1,256.26

1 Piece(s) 6 Day(s) or more 10820.584P9.571.2547.5395.5Rated voltage: Uo/U (V) Uo = Voltage between conductor and ground, U = voltage between conductors

SGD 1,271.54

1 Piece(s) 6 Day(s) or more 10830.584P9.571.2547.5395.5Rated voltage: Uo/U (V) Uo = Voltage between conductor and ground, U = voltage between conductors

SGD 1,286.82

1 Piece(s) 6 Day(s) or more 10840.584P9.571.2547.5395.5Rated voltage: Uo/U (V) Uo = Voltage between conductor and ground, U = voltage between conductors

SGD 1,302.09

1 Piece(s) 6 Day(s) or more 10850.584P9.571.2547.5395.5Rated voltage: Uo/U (V) Uo = Voltage between conductor and ground, U = voltage between conductors

SGD 1,317.37

1 Piece(s) 6 Day(s) or more 10860.584P9.571.2547.5395.5Rated voltage: Uo/U (V) Uo = Voltage between conductor and ground, U = voltage between conductors

SGD 1,332.64

1 Piece(s) 6 Day(s) or more 10870.584P9.571.2547.5395.5Rated voltage: Uo/U (V) Uo = Voltage between conductor and ground, U = voltage between conductors

SGD 1,347.92

1 Piece(s) 6 Day(s) or more 10880.584P9.571.2547.5395.5Rated voltage: Uo/U (V) Uo = Voltage between conductor and ground, U = voltage between conductors

SGD 1,363.19

1 Piece(s) 6 Day(s) or more 10890.584P9.571.2547.5395.5Rated voltage: Uo/U (V) Uo = Voltage between conductor and ground, U = voltage between conductors

SGD 1,378.47

1 Piece(s) 6 Day(s) or more 10900.584P9.571.2547.5395.5Rated voltage: Uo/U (V) Uo = Voltage between conductor and ground, U = voltage between conductors

SGD 1,393.75

1 Piece(s) 6 Day(s) or more 10910.584P9.571.2547.5395.5Rated voltage: Uo/U (V) Uo = Voltage between conductor and ground, U = voltage between conductors

SGD 1,409.02

1 Piece(s) 6 Day(s) or more 10920.584P9.571.2547.5395.5Rated voltage: Uo/U (V) Uo = Voltage between conductor and ground, U = voltage between conductors

SGD 1,424.29

1 Piece(s) 6 Day(s) or more 10930.584P9.571.2547.5395.5Rated voltage: Uo/U (V) Uo = Voltage between conductor and ground, U = voltage between conductors

SGD 1,439.57

1 Piece(s) 6 Day(s) or more 10940.584P9.571.2547.5395.5Rated voltage: Uo/U (V) Uo = Voltage between conductor and ground, U = voltage between conductors

SGD 1,454.85

1 Piece(s) 6 Day(s) or more 10950.584P9.571.2547.5395.5Rated voltage: Uo/U (V) Uo = Voltage between conductor and ground, U = voltage between conductors

SGD 1,470.13

1 Piece(s) 6 Day(s) or more 10960.584P9.571.2547.5395.5Rated voltage: Uo/U (V) Uo = Voltage between conductor and ground, U = voltage between conductors

SGD 1,485.39

1 Piece(s) 6 Day(s) or more 10970.584P9.571.2547.5395.5Rated voltage: Uo/U (V) Uo = Voltage between conductor and ground, U = voltage between conductors

SGD 1,500.67

1 Piece(s) 6 Day(s) or more 10980.584P9.571.2547.5395.5Rated voltage: Uo/U (V) Uo = Voltage between conductor and ground, U = voltage between conductors

SGD 1,515.95

1 Piece(s) 6 Day(s) or more 10990.584P9.571.2547.5395.5Rated voltage: Uo/U (V) Uo = Voltage between conductor and ground, U = voltage between conductors

SGD 1,531.23

1 Piece(s) 6 Day(s) or more 101000.584P9.571.2547.5395.5Rated voltage: Uo/U (V) Uo = Voltage between conductor and ground, U = voltage between conductors

Loading...

Basic Information

Rated Voltage 300/300V Shield Tin plated copper braid Properties Oil Resistance
Representative Standard UL / CE / CSA(c-UL) Sheath (outer coating) color Gray Grounding Wire No grounding conductor
Sheath (outer coating) material Low adhesiveness PVC admixture Insulation body materials PP admixture Free span maximum running speed(m/s) 5
Slide maximum running speed(m/s) 3 Maximum acceleration(m/s2) 50 Stroke Up to 100 m
Other standards ISO class 1 (IPA): Clean room compatible/ CEI: Italian standard/ NFPA 79-2012: Used of UL (AWM) cable allowed Other cable properties Flame retardant and silicone free

Tech Support

Factory Automation, Electronics, Tools, & MRO (Maintenance, Repair and Operations)
Tel:(65) 6733 7211 / FAX:(65) 6733 0211
9:00am - 6:00pm (Monday - Friday)