[Features]
· A timer for use on a PCB of contact / non-contact output type.
· Two types are provided for control output, with the contact output (1a, 1b) it is 3A (AC250V low resistance load), with the non-contact output there is a maximum of 150mA and high capacity.
· 1 sec./10 sec./1 min./10 min. (type A), 6 sec./60 sec./6 min./60 min. (type B) with four time types in one apparatus offering multiple functions.
· The time can be operated remotely by the connection to an external varistor.
· Completely washable.
· A small scale size enabling installation in a one-inch-pitch rack (length × width × height: 17.75 × 36.9 × 19.5 mm).
· UL/CSA acquired.

PDF

Japanese Only

Part Number

Configured Part Number is shown.

H3FA-A DC12

DIP Timer Specifications

H3FA external appearance

H3FA external appearance

H3FA outline drawing

H3FA outline drawing

Time Specifications

FormatMaximum Scale TimeSet Time Range
Series H3FA-A
Series H3FA-SA
Series H3FA-AU
1 s0.1 to 1 s
10 s1 to 10 s
1 min0.1 to 1 min
Series H3FA-B
Series H3FA-SB
Series H3FA-BU
6 s0.6 to 6 s
60 s6 to 60 s
6 min0.6 to 6 min

Note 1. The above timing ranges apply when the internal variable resistor of Series H3FA is used.
Note 2. The external variable resistor may also be used by opening the terminal connected to the internal variable resistor.
Note 3. Wire the appropriate terminal to select a time setting range.

Performance

Variations In Operating Time±0.5% or less (percentage relative to maximum scale time) *1 *3
Set Error0 to +30% or less (percentage relative to maximum scale time, at 20°C, at rated voltage)
Recovery Time10 ms or less
Voltage Effect±1% or less (Percentage relative to maximum scale time. However, it is ±2% or less for 5, 6, 5/6 V DC.)
Temperature Effect±5% or less (percentage relative to maximum scale time) *1
Insulation Resistance100 MΩ or more (at 500 V DC megger)
Withstand Voltage1,500 V AC, 50/60 Hz, 1 min (between control output and operation circuit) *2 1,000 V AC, 50/60 Hz, 1 min (between non-continuous contacts) *2
VibrationEndurance10 to 55 Hz, half amplitude 0.375mm, 3 directions, 2 h each
Malfunction10 to 55 Hz, half amplitude 0.25mm, 3 directions, 10 min each
ShockEndurance1,000 m/s2, 3 axes, 6 directions, 3 times each
Malfunction100 m/s2, 3 axes, 6 directions, 3 times each
LifeMechanical10 million operations or more (no load, switching frequency 1,800 operations/h) *2
Electrical100,000 operations or more (250 V AC, 3 A, resistive load, switching frequency 1,800 operations/h) *2
MassContact output type approx. 15 g, non-contact output type approx. 10 g
*1. When using a time specification of 1 second, each standard value is ±10 ms.
* 2. Applies to the contact point type.
* 3. When using the internal variable resistor of Series H3FA. (Not including when an externally connected resistor is used.)
Part Number
H3FA-A DC12
Part NumberStandard Unit PriceMinimum order quantityVolume DiscountDays to ShipTime specifications
(s)
Output Method Rated power supply voltage
(V)
Contact Configuration

SGD 46.95

1 Piece(s) 4 Day(s) or more 1 s – 10 minRelay12Includes contact output (1a, 1b)

Loading...

  1. 1
 

Basic Information

Type Time switch Display method No display function Mounting Method Surface mounting
Power Supply Voltage Dedicated to DC Representative Standard UL / CSA Dimension vertical(mm) 17.75
Dimension width(mm) 36.9 Dimension depth(mm) 19.5 Time ranges = N 4 range

Please check the type/dimensions/specifications of the part H3FA-A DC12 in the Dip Timer H3FA series.

Similar Part Numbers

Part Number
H3FA-A DC24
H3FA-A DC5
H3FA-AU DC12
H3FA-AU DC24
H3FA-B DC12
H3FA-B DC24
Part NumberStandard Unit PriceMinimum order quantityVolume DiscountDays to ShipTime specifications
(s)
Output Method Rated power supply voltage
(V)
Contact Configuration

SGD 46.95

1 Piece(s) Same day 1 s – 10 minRelay24Includes contact output (1a, 1b)

SGD 46.95

1 Piece(s) 4 Day(s) or more 1 s – 10 minRelay5Includes contact output (1a, 1b)

SGD 58.93

1 Piece(s) 4 Day(s) or more 1 s – 10 minRelay12Includes contact output (1a, 1b)

SGD 58.93

1 Piece(s) 4 Day(s) or more 1 s – 10 minRelay24Includes contact output (1a, 1b)

SGD 46.95

1 Piece(s) 4 Day(s) or more 6 s – 60 minRelay12Includes contact output (1a, 1b)

SGD 46.95

1 Piece(s) 4 Day(s) or more 6 s – 60 minRelay24Includes contact output (1a, 1b)

Tech Support

Factory Automation, Electronics, Tools, & MRO (Maintenance, Repair and Operations)
Tel:(65) 6733 7211 / FAX:(65) 6733 0211
9:00am - 6:00pm (Monday - Friday)