Power relay G2RL

Power relay G2RL
  • On Sale Till 31/03/2025

A low-profile power relay with a height of just 15.7 mm, enabling it to be incorporated into small-sized equipment.
[Features]
· 1-pole, 2-pole and high-capacity types are available.
· High sensitivity with a power consumption of 400 mW.
· A highly insulated type with an impact withstand voltage of 10 kV and a minimum 8 mm insulation distance between the coil and contacts.
· Ambient operating temperature of -40 to 85°C.
· Complies with VDE standards as standard.
[Applications]
· For PCBs used in communications equipment, OA equipment, testing instruments, disaster/crime-prevention devices, security devices, etc.

PDF

Power Relay G2RL Specifications

Power Relay G2RL: related images

G2RL external appearance

Power Relay G2RL: related images

G2RL-1 composition

Power Relay G2RL: related images

G2RL-1 dimensional drawing, Units: mm
*Average dimensions.

Power Relay G2RL: related images

G2RL-1 PCB processing dimensional drawing

Power Relay G2RL: related images

G2RL-1 terminal layout/schematics
There is no coil polarity.

Power Relay G2RL: related images

G2RL-1A-E composition

Power Relay G2RL: related images

G2RL-1A-E dimensional drawing, Units: mm
*Average dimensions.

Power Relay G2RL: related images

G2RL-1A-E PCB processing dimensional drawing

Power Relay G2RL: related images

G2RL-1A-E terminal layout/schematics
There is no coil polarity.

Power Relay G2RL: related images

Reference data: Ambient temperature and maximum allowable voltage
Note: The maximum allowable voltage is the maximum voltage that can be applied to a relay coil.

ClassificationStandard TypeHigh Capacity Type
Number of Contacts1 Pole2 Pole1 Pole
ItemsContact Resistance *1100 mΩ or Less
Turn-ON Time15 ms or Less
Turn-OFF Time5 ms or Less
Maximum Switching FrequencyMechanical18,000 Times/h
Rated Load1,800 Times/h
Insulation Resistance *21,000 MΩ or More
Withstand VoltageBetween Coil and Contact5,000 V AC 50/60 Hz 1 min
Between Contacts of Same Polarity1,000 V AC 50/60 Hz 1 min
Between Contacts of Different Polarities-2,500 V AC 50/60 Hz 1 min-
Insulation DistanceBetween Coil and ContactSpace: 8 mm, Creepage: 8 mm
Impulse Withstand Voltage10 kV (1.2 × 50 μs)
VibrationDurability10 to 55 to 10 Hz, Semi Amplitude 0.75 mm (Double Amplitude 1.5 mm)
Malfunction10 to 55 to 10 Hz, Semi Amplitude 0.75 mm (Double Amplitude 1.5 mm)
Shock / ImpactDurability1,000 m/s2
MalfunctionEnergized: 100 m/s2, Non-Energized: 100 m/s2
DurabilityMechanical20,000,000 Times or More (Switching Frequency: 18,000 Times/h)
Electrical *3
(Resistance Load)
Model: G2RL-1A
: 250 V AC 10 A, 100,000 Times
: 24 V DC 10 A, 30,000 Times
Model G2RL-1
: 250 V AC 10 A, 50,000 Times
: 24 V DC 10 A, 30,000 Times
Model: G2RL-2A
: 250 V AC 5 A, 100,000 Times
: 24 V DC 5 A, 30,000 Times
Model G2RL-2
: 250 V AC 5 A, 50,000 Times
: 24 V DC 5 A, 30,000 Times
Model: G2RL-1A-E(-ASI)
: 250 V AC 16 A, 50,000 Times
: 24 V DC 16 A, 30,000 Times
Model G2RL-1-E
: 250 V AC 16 A, 30,000 Times
: 24 V DC 16 A, 30,000 Times
Ambient Operating Temperature-40 to +85°C (Assuming No Freezing or Condensation)
Operating Ambient Humidity5 to 85% RH
WeightApprox. 12 g

Note: The above values are the initial default values.

  • *1. Measurement conditions: 5 V DC 1 A, voltage drop method.
  • *2. Measurement conditions: Measuring the same spot for the withstand voltage items using a 500 V DC insulation resistance meter.
  • *3 Switching frequency: 1,800 Times/h
  • *Refer to the catalog for specifications other than those above.
Part Number
G2RL-1 DC12
G2RL-1 DC24
G2RL-1-E DC12
G2RL-1-E DC24
G2RL-1A-E DC24
G2RL-2 DC5
G2RL-2 DC12
Part NumberStandard Unit PriceMinimum order quantityVolume DiscountDays to ShipContact Configuration Contact rated current (minimum value for AC and DC)
(A)
Coil rated voltage (DC)
(V)
Classification Note

SGD 6.37

SGD 1.27

1 Piece(s) Same day 1c1012Standard Type-

SGD 6.37

SGD 1.27

1 Piece(s) Same day 1c1024Standard Type-

SGD 7.28

SGD 1.46

1 Piece(s) Same day 1c1612High Capacity TypeHigh Capacity Type

SGD 6.36

SGD 1.27

1 Piece(s) Same day 1c1624Standard TypeHigh Capacity Type

SGD 7.13

SGD 1.43

1 Piece(s) Same day 1a1624High Capacity Type-

SGD 5.10

SGD 1.02

1 Piece(s) Same day 2c55Standard Type-

SGD 5.10

SGD 1.02

1 Piece(s) Same day 2c512Standard Type-

Loading...

  1. 1
 

Basic Information

Application Power Latch function NA Terminal shape For Circuit Boards
Representative Standard UL / CSA Dimension height(mm) 15.7 Dimension width(mm) 29
Dimension depth(mm) 12.7 Contact mechanism Single Protective Structure Flux resistant shape