Load Cell, mV Meter K3HB-V

Load Cell, mV Meter K3HB-V

[Features]
· Supporting load cell signal input, the optimal indicator for measurements such as pressure load torque weight, etc., and acceptance/rejection judgments of automatic machines, sorting machines, etc.
· Switches between 2 colors, red and green, to show the operation judgment with the display color.
· Equipped with a position meter to show the operational state trends.
· An external event input enables expansion to a wide range of measurement judgment applications.
· DC0.001mV or higher can be input (0.000 to 19.999mV range available).
· Also equipped with DC10V 100mV external power supply (DC5V type also available).
· Series developed for DeviceNet types.
· Short body size with depth (under neck) of 95 mm.
· Certified under UL standards (mark license certified).
· CE marking compliant as evaluated by a third party, waterproof structure compliant with NEMA4X (IP66 equivalent).

PDF

Japanese Only

Load Cell, mV Meter K3HB-V Outline Drawing And Dimensions

Load Cell, mV Meter K3HB-V Outline Drawing

Load Cell, mV Meter K3HB-V Outline Drawing

Dimensional drawing

Dimensional drawing

Side view

Side view

Panel machining dimensions

Panel machining dimensions

K3HB-V Specifications

External Power Supply

Input TypeOutput TypeK3HB-V
Event Input Terminal Block 5 Points (TIMING, S-TIM, HOLD, RESET, ZERO) Equipped
External Power Supply 10 V DC, 100 mA
96 (W) × 48 (H) × Depth 95 mm
 Output Type
(2)
Output Type
(1)
100 to 240 V AC
Load Cell,
mV Input Type
No Output-Series K3HB-VLC-B1 AC100-240
Relay ContactPASS 1cH, L: 1c eachSeries K3HB-VLC-CPBC11 AC100-240
HH, H, L, LL: 1a eachSeries K3HB-VLC-CPBC21 AC100-240
Transistor-NPN Open Collector
(HH, H, PASS, L, LL)
Series K3HB-VLC-BT11 AC100-240
BCD+ Transistor-NPN Open Collector
(5-Digit Output +HH, H, PASS, L, LL)
Series K3HB-VLC-BBCD1 AC100-240
CommunicationRS-485NPN Open Collector
(HH, H, PASS, L, LL)
Series K3HB-VLC-FLK3BT11 AC100-240
LinearCurrentNPN Open Collector
(HH, H, PASS, L, LL)
Series K3HB-VLC-L1BT11 AC100-240
VoltageNPN Open Collector
(HH, H, PASS, L, LL)
Series K3HB-VLC-L2BT11 AC100-240

10 V DC 100 mA type (100 to 240 V AC)

Input TypeOutput TypeSeries K3HB-V
Event Input Terminal Block 5 Points (TIMING, S-TIM, HOLD, RESET, ZERO) Equipped
External Power Supply 10 V DC, 100 mA
96 (W) × 48 (H) × Depth 95 mm
 Output Type
(2)
Output Type
(1)
24 V AC / V DC
Load Cell,
mV Input Type
No Output-Series K3HB-VLC-B1 AC/DC24
Transistor-NPN Open Collector
(HH, H, PASS, L, LL)
Series K3HB-VLC-BT11 AC/DC24

10 V DC 100 mA type (24 V AC / V DC)

Rating/Performance

External Power Supply10 V DC 100 mA Type
Power Supply Voltage100 to 240 V AC, 24 V AC / V DC, DeviceNet Power Supply: 24 V DC
Allowable Power Supply Voltage Range85 to 110% of rated power supply voltage, DeviceNet power supply: 11 to 25 V DC
Power Consumption (At Maximum Load)*1100 to 240 V AC: 18 VA or less, 24 V AC / V DC: 11 VA / 7 W or less
Current ConsumptionDeviceNet Power Supply: 50 mA Or Less (24 V DC)
Input SignalDC Voltage
Measurement MethodDelta-Sigma Method
External Power Supply10 V DC ±5% 100 mA
(Type with external power supply only)
Event Input
*2
Timing InputNPN open collector or non-voltage contact signal
Residual voltage at short circuit (residual voltage when ON): 3 V or less
Maximum applied voltage: 30 V DC or less
Current at short circuit (when 0 Ω): 17 mA or less
Leak current (leak current when OFF): 1.5 mA or less
Start-Up Compensation Timer InputNPN open collector or non-voltage contact signal
Residual voltage at short circuit (residual voltage when ON): 2 V or less
Current at short circuit (when 0 Ω): 4 mA or less
Maximum applied voltage: 30 V DC or less
Leak current (leak current when OFF): 0.1 mA or less
Hold Input
Reset Input
Forced Zero Input
Bank Input
Output (Differs Based On Model)Relay Contact Output250 V AC / 30 V DC 5 A (resistive load), mechanical life: 5 million operations, electrical life 100,000 operations
Transistor OutputMaximum load voltage: 24 V DC, maximum load current: 50 mA, leak voltage: 100 μA or less
Linear OutputDC 0 to 20 mA / DC 4 to 20 mA:
Load: 500 Ω or less, resolution: approx. 10,000, output error: ±0.5% FS
0 to 5 V DC / 1 to 5 V DC / 0 to 10 V DC:
Load: 5 kΩ or more, resolution: approx. 10,000, output error: ±0.5% FS
However, ±0.15 V below 1 V (no output for 0 V or less)
Display MethodNegative LCD (backlight LED) display
· 7-segment digital display (character height PV: 14.2 mm [switchable between green and red], SV: 4.9 mm [green])
Main FunctionsScaling function, measurement operation selection, averaging processing, previous average comparison, forced zero,
zero limit, output hysteresis, output OFF delay, output test, teaching,
display value selection, display color switching, key protect, bank switching, display refresh cycle,
MAX/MIN hold, reset
Operating Temperature RangeWhen In Use-10 to +55°C (No Freezing Or Condensation)
When Stored-25 to +65°C (No Freezing Or Condensation)
Operating Humidity RangeWhen In Use25 to 85% RH
Height2,000 m or less
AccessoriesIn addition to waterproof packing, fixtures × 2, a terminal cover, a unit sticker, and an instruction manual, the DeviceNet type also includes a DeviceNet connector (Hirose Electric: HR31-5.08P-5SC [01]) and a crimp terminal (Hirose Electric: HR31-SC-121). *3

Rating

*1. For DC power supply types, a control power supply capacity of approx. 1 A per unit is required when powering ON. Be especially careful when using multiple units.
S8VS series (OMRON) is recommended for DC power supply.
*2. A PNP input type is also available.
*3. For the K3HB series DeviceNet type, it cannot be used with anything other than the included DeviceNet connector. Additionally, the included crimp terminal is for thin cables.

Displayable Range-19,999 to 99,999
Sampling Cycle50 times/s (20 ms)
Comparison Output Answer Time100 ms or less (time until comparison output is output when input signal suddenly changes from 15% to 95% or 95% to 15%)
Linear Output Answer Time150 ms or less (convergence time to the final value of the analog output when output signal suddenly changes from 15% to 95% or 95% to 15%)
Insulation Resistance20 MΩ or more (at 500 V DC megger)
Withstand Voltage2,300 V AC, 1 min, between external terminals and case
Noise Resistance100 to 240 V AC type: power supply terminal normal / common mode ±1,500 V (rise 1 ns wave, pulse width 1 μs, 100 ns)
24 V AC / V DC type: power supply terminal normal / common mode ±1,500 V (rise 1 ns wave, pulse width 1 μs, 100 ns)
Vibration-ResistantFrequency: 10 to 55 Hz, acceleration: 50 m/s2 5 min each in X, Y, Z directions × 10 sweeps
Shock-Resistant150 m/s2 (however, 100 m/s2 for relay contact), 3 axes, 6 directions, 3 times each
Main Body MassApprox. 300 g (Main Body Only)
Protective
Structure
FrontNEMA4X Indoor Compliant (IP66 Equivalent)
Rear CaseIP20
TerminalIP00 + Finger Protection (VDE0106/100)
Memory ProtectionEEPROM (non-volatile memory), number of writes: 100,000 times
Compatible StandardsUL61010-1, CSA C22.2 No. 61010-1-04, EN61010-1 (IEC61010-1)
Pollution Degree 2 / Overvoltage Category II
EN61326-1
EMC(EMI):EN61326-1 industrial electromagnetic environment application
Radiation interference field strength: CISPR 11 Group 1, class A
Noise terminal voltage: CISPR 11 Group 1, class A
(EMS): EN61326-1 industrial electromagnetic environment application
Electrostatic discharge immunity: EN61000-4-2: 4 kV (direct), 8 kV (atmospheric)
Field strength immunity: EN61000-4-3: 10 V/m sinusoidal amplitude modulation (80 MHz to 1 GHz, 1.4 to 2 GHz)
Fast transient / burst noise immunity: EN61000-4-4: 2 kV (power supply line), 1 kV (I/O signal line)
Surge immunity: EN61000-4-5: 1 kV between lines (power supply line), 2 kV between grounds (power supply line)
Conductive noise immunity: EN61000-4-6: 3 V (0.15 to 80 MHz)
Commercial frequency magnetic field immunity: EN61000-4-8: 30 A/m (50 Hz) continuous time
Voltage dip / interruption immunity: EN61000-4-11: 0.5 cycles, 0°/180°, 100% (rated voltage)

Performance

  • *Refer to the catalog for other detailed specifications.

Features of this product

Switches between 2 colors, red and green, to show the operation judgment with the display color.

Measurement value display can be switched between a color display of green or red according to the comparison output operation.
The situation can be easily grasped even from afar.

Shows the operational state trends. Equipped with a position meter

Shows the operational state trends. Equipped with a position meter
Display the current status against the measurement range or full scale of the display range as a bar graph. The operating state is intuitively grasped, making it easy to judge the level amount, threshold amount, etc.

An external event input enables use in a wide range of measurement judgment applications.

An external event input enables use in a wide range of measurement judgment applications
Expanded range of applications such as inspection/judgment applications synchronized with external signals, etc.

High-speed sampling of 50 cycles/second (20 ms)

High-speed sampling of 50 cycles/second (20 ms)
Achieves an input sampling cycle of 50 times/second, at least 3× higher than conventional products (12.5× for temperature input type).
In addition to improving the responsiveness of judgment output and transmission output, measurement stability is enhanced by averaging processing.

Short body size with depth (under neck) of 95 mm

Short body size with depth (under neck) of 95 mm
Shortened body with a depth of 95 mm.
Contributes to thinner and more compact control panels and equipment.

Part Number
K3HB-VLC-B1 AC100-240
K3HB-VLC-B1 AC/DC24
K3HB-VLC-BBCD1 AC100-240
K3HB-VLC-BT11 AC/DC24
K3HB-VLC-CPBC11 AC100-240
K3HB-VLC-CPBC21 AC100-240
K3HB-VLC-FLK3BT11 AC100-240
K3HB-VLC-L1BT11 AC100-240
K3HB-VLC-L2BT11 AC100-240
Part NumberStandard Unit PriceMinimum order quantityVolume DiscountDays to ShipOutput Type Number of Outputs Communication Type Power Supply Voltage
(V)

SGD 500.90

1 Piece(s) 7 Day(s) or more NA-NAAC 100–240

SGD 538.83

1 Piece(s) 67 Day(s) NA-NAAC/DC24

SGD 974.83

1 Piece(s) 7 Day(s) or more BCD output/transistor output (NPN)5NAAC 100–240

SGD 574.86

1 Piece(s) 7 Day(s) or more Transistor output (NPN)5NAAC/DC24

SGD 553.27

1 Piece(s) 4 Day(s) or more Relay contact output (1c)3NAAC 100–240

SGD 574.86

1 Piece(s) 7 Day(s) or more Relay contact output (1a/1c)5NAAC 100–240

SGD 618.04

1 Piece(s) 18 Day(s) or more Transistor output (NPN)5RS-485AC 100–240

SGD 790.75

1 Piece(s) 7 Day(s) or more Linear current/transistor output (NPN)5NAAC 100–240

SGD 790.75

1 Piece(s) 7 Day(s) or more Linear voltage/transistor output (NPN)5NAAC 100–240

Loading...

  1. 1
 

Basic Information

Mounting Method Panel Mount Panel cut dimensions 92x45 Standard CE / UL / CSA
Dimension length(mm) 48 Dimension width(mm) 96 Dimension thickness(mm) 95
Input Type Load cell signal signal/mV signal Calculation function Scaling Display Digits 5 digits
Sampling cycle 20ms Protective structure (front) NEMA4X (corresponding to IP66)

Tech Support

Factory Automation, Electronics, Tools, & MRO (Maintenance, Repair and Operations)
Tel:(65) 6733 7211 / FAX:(65) 6733 0211
9:00am - 6:00pm (Monday - Friday)