(!)Due to Microsoft's end of support for Internet Explorer 11 on 15/06/2022, this site does not support the recommended environment.
Instead, please kindly use other browsers like Google Chrome, Microsoft Edge or Mozilla Firefox.
A wide variety of standard and configurable components for factory automation engineers in industries such as automotive, semiconductor, packaging, medical and many more.
A good selection of accessories such as screws, bolts, washers and nuts that you may need for your daily engineering usage.
Browse industrial materials ranging from heat insulating plates, sponges, to metal and plastic materials in different sizes to meet your various applications.
A wide variety of wiring parts for connecting and protecting control and PC parts including Connectors, Cables, Electric Wires, Crimping Terminals and more.
A wide variety of controls and PC parts for electrical engineers including Controls, Powers, PC parts and more.
A wide variety of cutting tools for many uses and work materials including End Mills, Drills, Cutters, Reamers, Turning Tools and more.
A wide variety of tools and supplies used in processing including Machine Tools, Measurement Tools, Grinding and Polishing Supplies and more.
A wide variety of goods used in shipment, material handling and warehouse including Tape supplies, Stretch film, Truck, Shelf, Crane and more.
A large variety of goods for every kind of factories and offices including Protection items, Cleaning supplies, sanitations, office supplies and more.
A large variety of items used in R&D and Clean Room including research Equipment, Laboratory Essentials, Analysis Supplies, Clean Environment-Related Equipment and more.
Choose from thousands of standard stamping die components including Punch & Die, Gas Springs, Guide Components, Coil Springs and many more.
Browse our wide variety of mold components including Ejector Pins, Sleeves, Leader Components, Sprue Bushings and many more.
Browse our injection molding components including Heating Items, Couplers, Hoses and more.
[Features]
· A small and high sensitivity single-pole relay for signal switching.
· Small size: 12.5 (L) × 7.5 (W) × 10 (H) mm.
· Features a wide contact switching region of 1mA to 1 A.
· High sensitivity coil: 150mW.
· A sealed plastic type with high environmental resistance.
· FCCpart68 compliant (1,500V, 10 × 160 μs) between coil-contacts.
Japanese Only
Part Number
Configured Part Number is shown.
G5V-1 external appearance
G5V-1 dimensional outline drawing
PCB processing drawing
Items | Rated Current (mA) | Coil Resistance (Ω) | Operating Voltage (V) | Release Voltage (V) | Maximum Allowable Voltage (V) | Power Consumption (mW) | |
---|---|---|---|---|---|---|---|
Rated Voltage (V) | |||||||
DC | 3 | 50 | 60 | 80% or Less | 10% or More | 200% (at 23°C) | Approx. 150 |
5 | 30 | 167 | |||||
9 | 16.7 | 540 | |||||
12 | 12.5 | 960 | |||||
24 | 6.25 | 3,840 |
Note 1: The rated current and coil resistance are measured at a coil temperature of +23°C and a tolerance of 10%.
Note 2: The operating characteristics are measured at a coil temperature of +23°C.
3. The maximum allowable voltage is the maximum voltage that can be applied to a relay coil.
4. Model G5V-1-2 (with an operating voltage of 70% or less) is also available as part of a special product series.
Load | Resistance Load |
---|---|
Contact Touching Mechanism | Single Crossbar Contact |
Contact Material | Au Alloy + Ag |
Rated Load | 125 V AC 0.5 A, 24 V DC 1 A |
Rated Conduction Current | 2 A |
Maximum Contact Voltage Value | 125 V AC 60 V DC |
Maximum Contact Current Value | 1 A |
Contact Resistance *1 | 100 mΩ or Less | |
---|---|---|
Turn-ON Time | 5 ms or Less | |
Turn-OFF Time | 5 ms or Less | |
Insulation Resistance *2 | 1,000 MΩ or More | |
Withstand Voltage | Between Coil and Contact | 1,000 V AC 50/60 Hz 1 min |
Between Contacts of Same Polarity | 400 V AC 50/60 Hz 1 min | |
Vibration | Durability | 10 to 55 to 10 Hz, Semi Amplitude 1.65 mm (Double Amplitude 3.3 mm) |
Malfunction | 10 to 55 to 10 Hz, Semi Amplitude 1.65 mm (Double Amplitude 3.3 mm) | |
Shock / Impact | Durability | 1,000 m/s2 |
Malfunction | 100 m/s2 | |
Durability | Mechanical | 5,000,000 Times or More (Switching Frequency: 36,000 Times/h) |
Electrical | 100,000 Times or More (Rated Load, Switching Frequency: 1,800 Times/h) | |
Failure Rate P Level (Reference Value *3) | 5 V DC, 1 mA | |
Ambient Operating Temperature | -40 to +70°C (Standard Type), -40 to +90°C (Model G5V-1-T90) (Assuming No Freezing or Condensation) | |
Operating Ambient Humidity | 5 to 85% RH | |
Weight | Approx. 2 g |
Note: The above values are the initial default values.
*1. Measurement conditions: 1 V DC 10 mA, voltage drop method.
*2. Measurement conditions: Measuring the same spot for the withstand voltage items using a 500 V DC insulation resistance meter between coil contacts and 250 V DC between contacts of the same polarity.
*3. This value is obtained with a switching frequency of 120 times/min. and a contact resistance failure value of 100 Ω. These values may vary depending on switching frequency and operating conditions, meaning it is always recommended to double-check under actual load conditions.
Part Number |
---|
G5V-1 DC3 |
G5V-1 DC5 |
G5V-1 DC9 |
G5V-1 DC12 |
G5V-1 DC24 |
Part Number | Standard Unit Price | Minimum order quantity | Volume Discount | Days to Ship | Coil rated voltage (DC) (V) |
---|---|---|---|---|---|
SGD 4.70 SGD 0.94 | 1 Piece(s) | Same day | 3 | ||
SGD 4.70 SGD 0.94 | 1 Piece(s) | Same day | 5 | ||
SGD 4.70 SGD 0.94 | 1 Piece(s) | Same day | 9 | ||
SGD 4.70 SGD 0.94 | 1 Piece(s) | Same day | 12 | ||
SGD 4.70 SGD 0.94 | 1 Piece(s) | Same day | 24 |
Loading...
Application | For Signals | Contact Configuration | 1c | Latch function | NA |
---|---|---|---|---|---|
Terminal shape | For Circuit Boards | Contact rated current (minimum value for AC and DC)(A) | 0.5 | Dimension height(mm) | 10 |
Dimension width(mm) | 12.5 | Dimension depth(mm) | 7.5 | Protective Structure | Plastic seal type |
Contact mechanism | Crossbar/single | Circuit Board Mounting | Circuit Board Hole Insertion | AC rated load(V)/(A) | AC125/0.5 |
DC rated load(V)/(A) | DC24/1 |