(!)Due to Microsoft's end of support for Internet Explorer 11 on 15/06/2022, this site does not support the recommended environment.
Instead, please kindly use other browsers like Google Chrome, Microsoft Edge or Mozilla Firefox.
A wide variety of standard and configurable components for factory automation engineers in industries such as automotive, semiconductor, packaging, medical and many more.
A good selection of accessories such as screws, bolts, washers and nuts that you may need for your daily engineering usage.
Browse industrial materials ranging from heat insulating plates, sponges, to metal and plastic materials in different sizes to meet your various applications.
A wide variety of wiring parts for connecting and protecting control and PC parts including Connectors, Cables, Electric Wires, Crimping Terminals and more.
A wide variety of controls and PC parts for electrical engineers including Controls, Powers, PC parts and more.
A wide variety of cutting tools for many uses and work materials including End Mills, Drills, Cutters, Reamers, Turning Tools and more.
A wide variety of tools and supplies used in processing including Machine Tools, Measurement Tools, Grinding and Polishing Supplies and more.
A wide variety of goods used in shipment, material handling and warehouse including Tape supplies, Stretch film, Truck, Shelf, Crane and more.
A large variety of goods for every kind of factories and offices including Protection items, Cleaning supplies, sanitations, office supplies and more.
A large variety of items used in R&D and Clean Room including research Equipment, Laboratory Essentials, Analysis Supplies, Clean Environment-Related Equipment and more.
Choose from thousands of standard stamping die components including Punch & Die, Gas Springs, Guide Components, Coil Springs and many more.
Browse our wide variety of mold components including Ejector Pins, Sleeves, Leader Components, Sprue Bushings and many more.
Browse our injection molding components including Heating Items, Couplers, Hoses and more.
A power relay with a high capacity and high dielectric strength that can handle momentary voltage drops.
[Features]
·No contact chattering for momentary voltage drops up to 50% of the rated voltage.
·A wide range coil that covers 100 V AC type from 100 to 120 V AC 50/60 Hz or 200 V AC type from 200 to 240 V AC 50/60 Hz with a single coil.
· High capacity that is particularly able to manage inductive loads with powerful force.
·All insulating materials are flame retardant and comply with UL94 V-0 standards.
· Comes in a wide variety of types including tab terminals, screw terminals, PCB terminals, etc. Surface connection sockets are also available.
·Standard products compliant with UL, CSA, and TÜV and meet the IEC950 standards.
· Safe design with 3 mm contact gap.
[Applications]
·Widely applicable to factory automation as well as non-factory automation equipment.
Japanese Only
Part Number
Configured Part Number is shown.
G7L-1A-TUB AC100/120
G7L external appearance
Model G7L-1A-T dimensional outline drawing (E-bracket mounting tab terminal type)
G7L-2A-T dimensional outline drawing (E-bracket mounting tab terminal type)
Mounting hole machining dimensions
Item | Rated Current (mA) | Coil Resistance (Ω) | Coil Inductance (H) | Operating Voltage | Release Voltage | Maximum Permissible Voltage | Power Consumption (VA/W) | ||
---|---|---|---|---|---|---|---|---|---|
Rated Voltage (V) | Armature When ON | Armature When OFF | On the Basis of Rated Voltage | ||||||
AC | 12 | 142 | - | - | - | 75% max. | 15% min. | 110% | Approx. 1.7 to 2.5 |
24 | 71 | ||||||||
50 | 34 | ||||||||
100 to 120 | 17.0 to 20.4 | 75 V max. | 18 V min. | 132 V | |||||
200 to 240 | 8.5 to 10.2 | 150 V max. | 36 V min. | 264 V | |||||
DC | 6 | 317 | 18.9 | 0.09 | 0.21 | 75% max. | 15% min. | 110% | Approx. 1.9 |
12 | 158 | 75 | 0.37 | 0.88 | |||||
24 | 79 | 303 | 1.42 | 3.54 | |||||
48 | 40 | 1,220 | 6.1 | 15.3 | |||||
100 | 19 | 5,260 | 21.3 | 60 |
Note 1. The rated current and coil resistance are measured at a coil temperature of 23°C with tolerances of +15%/-20% for AC rated current and ±15% for DC coil resistance. (The AC rated current is the same value for both 50 and 60 Hz.)
Note 2. The coil inductance shown is a reference value.
*The figures for the operating characteristics are for a coil temperature of +23°C.
Note 4. The maximum allowable coil voltage refers to the maximum value in a varying range of operating power voltage, measured at ambient temperature 23°C.
Note 5. The "to" (for example "100 to 120") represents the range of rated voltages.
Format | Model G7L-1A-T□ Model G7L-1A-B□ | Model G7L-2A-T□ Model G7L-2A-B□ | Model G7L-1A-P Model G7L-2A-P | |||
---|---|---|---|---|---|---|
Load | Resistive Load | Inductive Load (cosø = 0.4) | Resistive Load | Inductive Load (cosø = 0.4) | Resistive Load | Inductive Load (cosø = 0.4) |
Contact Mechanism | Double break | |||||
Contact Material | Ag alloy | |||||
Rated Load | 220 V AC 30 A | 220 V AC 25 A | 220 V AC 25 A | 220 V AC 20 A | ||
Rated Carry Current | 30 A | 25 A | 0 to 20 A | |||
Max. Contact Voltage Value | 250 V AC | |||||
Max. Contact Current Value | 30 A | 25 A | 20 A |
Note: When using B-series (screw) products, since the screw diameter of the contact terminal is M4, be careful that the contact current should be 20 A or less according to JET standard (electrical appliance and material control law of Japan).
"m-h3--wysiwyg">PerformanceContact Resistance *1 | 50 mΩ max. | |
---|---|---|
Operating Time *2 | 30 ms max. | |
Recovery Time *2 | 30 ms max. | |
Maximum Switching Frequency | Mechanical | 1,800 operations/hr |
Rated Load | 1,800 operations/hr | |
Insulation Resistance *3 | 1,000 MΩ min. | |
Dielectric Strength | Between Coil and Contacts | 4,000 V AC 50/60 Hz for 1 min |
Between Contacts of Same Polarity | 2,000 V AC 50/60 Hz for 1 min | |
Between Contacts of Different Polarity (2a Type) | ||
Impulse Withstand Voltage | Between Coil and Contacts: 10,000 V *4 | |
Vibration | Durability | 10 to 55 to 10 Hz, 0.75-mm single amplitude (1.5-mm double amplitude) |
Malfunction | 10 to 55 to 10 Hz, 0.75-mm single amplitude (1.5-mm double amplitude) | |
Shock | Durability | 1,000 m/s2 |
Malfunction | 100 m/s2 | |
Durability | Mechanical | 1,000,000 operations min. (at approx. 1,800 operations/h) |
Electrical *5 | 100,000 operations min. (at 1,800 operations/hr under rated load) | |
Failure Rate (P Level) (Reference Value *6) | 5 V DC 100 mA | |
Weight | Approx. 90 g: (tab terminal type) | |
Approx. 100 g: (PCB terminal type) | ||
Approx. 120 g: (screw terminal type) | ||
Ambient Operating Temperature | -25 to +60°C (assuming no icing or condensation) | |
Ambient Operating Humidity | 5 to 85% RH |
Note: The values given above are initial values.
*1. Measurement conditions: 5 V DC, 1 A, voltage drop method.
*2. Measurement conditions: Rated operating voltage applied, not including contact bounce. Ambient temperature: +23°C
*3. Measured with a 500 V DC ohmmeter at the same places that the dielectric strength was checked.
*4. JEC-212 (1981) Standard Impulse Wave Type (1.2 × 50 μs).
*5. Ambient temperature: +23°C
*6. This value was measured at a switching frequency of 60 operations/min.
Part Number |
---|
G7L-1A-TUB AC100/120 |
Part Number | Standard Unit Price | Minimum order quantity | Volume Discount | Days to Ship | RoHS | Contact Configuration | Terminal shape | Contact rated current (minimum value for AC and DC) (A) | Coil rated voltage (DC) (V) | Coil rated voltage (AC) (V) | Dimension height (mm) | Dimension width (mm) | Dimension depth (mm) | Input Type | Bargain Article |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
SGD 20.94 SGD 4.19 | 1 Piece(s) | Same day | - | 1a | Tab Terminal | 25 | - | 100/120 | 55 | 52.5 | 34.5 | 20 per Tray | - |
Loading...
Application | Power | Contact mechanism | Double break |
---|
Please check the type/dimensions/specifications of the part G7L-1A-TUB AC100/120 in the Power Relay G7 L series.
Part Number |
---|
G7L-1A-BUB AC200/240 |
G7L-1A-BUB DC12 |
G7L-1A-BUB DC24 |
G7L-1A-TUB AC200/240 |
G7L-1A-TUB DC12 |
G7L-1A-TUB DC24 |
Part Number | Standard Unit Price | Minimum order quantity | Volume Discount | Days to Ship | RoHS | Contact Configuration | Terminal shape | Contact rated current (minimum value for AC and DC) (A) | Coil rated voltage (DC) (V) | Coil rated voltage (AC) (V) | Dimension height (mm) | Dimension width (mm) | Dimension depth (mm) | Input Type | Bargain Article |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
SGD 27.90 | 1 Piece(s) | Same day | - | 1a | Screw Fastening | 25 | - | 200/240 | 49 | 68.5 | 34.5 | 20 per Tray | - | ||
SGD 39.46 | 1 Piece(s) | 4 Day(s) or more | 10 | 1a | Screw Fastening | 30 | - | - | 49 | 68.5 | 34.5 | - | N/A | ||
SGD 26.09 | 1 Piece(s) | Same day | - | 1a | Screw Fastening | 25 | 24 | - | 49 | 68.5 | 34.5 | 20 per Tray | - | ||
SGD 18.00 | 1 Piece(s) | 89 Day(s) | - | 1a | Tab Terminal | 25 | - | 200/240 | 55 | 52.5 | 34.5 | 20 per Tray | - | ||
SGD 31.20 | 1 Piece(s) | Same day | - | 1a | Tab Terminal | 25 | 12 | - | 55 | 52.5 | 34.5 | 20 per Tray | - | ||
SGD 14.50 | 1 Piece(s) | Same day | - | 1a | Tab Terminal | 25 | 24 | - | 55 | 52.5 | 34.5 | 20 per Tray | - |