Total counter/Time counter (DIN72 × 36) H7HP (Part Numbers)

Total counter/Time counter (DIN72 × 36) H7HP
  • On Sale Till 31/03/2025

[Features]
· Ease of view and IP66 oil resistant level water resistance, and DIN72 oil resistance × 36 size total counter/time counter.
· Large scale display with an alphanumerics height of 15 mm in the 6 figure type and 12 mm in the 8 figure type.
· Low power consumption enabled with the same visibility as LCD by the use of negative type LED and red color LED.
· By using an integrated front part and casing and oil resistant materials for parts, it meets IP66 oil resistance and NEMA4.
· Implements a short barrel shape with a neck-down length of 66mm.
· The 6 figure type enables switching between total counter and time counter.
· Flip switches NPN and PNP to deal with each input mode.
· Can be both externally reset and manually reset.
· With a finger safe terminal block cover for protection against electric shocks, which conforms to VDE0106Part100.
· Safety standard UL, CSA acquired.
· EMC (EN61326) compatible, corresponds to the CE mark.

PDF

Japanese Only

Part Number

Configured Part Number is shown.

H7HP-AD

DIN 72 × 36 Size Total Counter / Time Counter

H7HP external appearance

H7HP external appearance

 
Counter main body dimensional outline drawing

Counter main body dimensional outline drawing

 
Dimensional outline drawing when adapter is mounted

Dimensional outline drawing when adapter is mounted

Rating

Format6-Digit Total Counter / Time Counter8-Digit Total Counter
ItemSeries H7HP-ASeries H7HP-ADSeries H7HP-C8Series H7HP-C8D
Power Supply Voltage100 to 240 V AC (50/60 Hz)12 to 24 V DC *1100 to 240 V AC (50/60 Hz)12 to 24 V DC *1
External Power Supply12 V DC, 50 mA-12 V DC, 50 mA-
Allowable Voltage Variation Range85 to 110% of rated power supply voltage
Power ConsumptionAC power supply: 6.5 VA or less, DC power supply: 0.6 W or less
External DimensionsWidth 72 × Height 36 × Depth 66 (Under Neck Length) mm
Mounting MethodEmbedded Mounting
External Connection MethodScrew-Fastening Terminal
Protective StructureIP66 oil resistance, U.S. NEMA standard type 4 (indoors), panel surface only
Display Method7-Segment Negative Type LCD (With Red Backlight)
Number Of Digits (Character Height)6 Digits (Character Height 15 mm)8 Digits (Character Height 12 mm)
FunctionTotal counter / time counter common
(switching by DIP switch)
Total Counter
Input ModeAddition/subtraction (individual input) (when total counter)·
Cumulative (when time counter)
Addition/subtraction (individual input)
Maximum Counting Speed30 Hz / 5 kHz (switching by DIP switch)
Counting Range-99,999 to 999,999-9,999,999 to 99,999,999
Time Specifications0.1 to 99,999.9 h / 1 s to 99 h 59 min 59 s
(switching by DIP switch)
-
Time Accuracy±100 ppm (-10 to +55°C)-
Power Failure Memory MethodBackup with EEP-ROM (200,000 rewrites or more)
Data retention: 20 years or more
InputInput SignalCount 1/start, count 2/gate, reset, key protect *2
Input MethodNon-voltage input (NPN transistor input, contact input)/
Voltage input (PNP transistor input) common (switching by DIP switch)
Count,
Start,
Gate,
Reset
· Non-voltage input (NPN transistor input, contact input)
Impedance at short circuit (when ON): 1 kΩ or less
Residual voltage at short circuit (when ON): 2 V DC or less
Impedance when opening (when OFF): 100 kΩ or more
· Voltage input (PNP transistor input)
Impedance at short circuit (when ON): 1 kΩ or less
ON voltage: 9 to 24 V DC
OFF voltage: 5 V DC or less
Impedance when opening (when OFF): 100 kΩ or more
Key Protect
*2
· Non-voltage input (NPN transistor input, contact input)
Impedance at short circuit (when ON): 1 kΩ or less, residual voltage at short circuit (when ON): 0.5 V DC or less
Impedance when opening (when OFF): 100 kΩ or more
Input
Answer
Speed
ResetWhen time counter: 20 ms, when total counter: 20 ms/1 ms (automatic switching according to counting speed)
StartWhen time counter: 20 ms-
Key ProtectApprox. 1 s
Recovery MethodExternal reset, manual reset
Ambient Operating Temperature-10 to +55°C (No Freezing)
Storage Temperature-25 to +65°C (No Freezing)
Ambient Operating Humidity35 to 85%
Case ExteriorGray smoke (front only is 5Y7/1 [light gray] or N1.5 [black])

*1. Ripple content is 20% (p-p) or less.
*2. Key protect input is non-voltage input (NPN transistor input, contact input) only. Even if NPN/PNP input mode is set to PNP, key protect input is non-voltage input. Key protect inhibits operation of the reset key. Reset input terminal function is valid.

Performance

Insulation Resistance100 MΩ or more (at 500 V DC megger)
Withstand Voltage2,000 V AC, 1 min, between the conductive part terminal and exposed non-charging metal part (AC type)
1,000 V AC, 1 min, between the conductive part terminal and exposed non-charging metal part (DC type)
2,000 V AC, 1 min, between the power supply terminal and control input terminal (AC type)
Impulse Voltage3 kV (between power supply terminals); however, 1 kV for 12 to 24 V DC type
4.5 kV (between the conductive part terminal and exposed non-charging metal part); however, 1.5 kV for 12 to 24 V DC type
Noise Resistance±1.5 kV (between AC power supply terminals), ±480 V (between DC power supply terminals), ±480 V (between input terminals)
Square-wave noise by noise simulator (pulse width 100 ns, 1 μs rise 1 ns)
Electrostatic StrengthDisplay: Malfunction 8 kV, Destruction 15 kV
DIP Switch: Malfunction 4 kV, Destruction 8 kV
VibrationEndurance10 to 55 Hz, half amplitude 0.75 mm, 3 directions, 2 h each
Malfunction10 to 55 Hz, half amplitude 0.5 mm, 3 directions, 10 min each
ShockEndurance294 m/s2, 3 axes each direction, 3 times each
Malfunction196 m/s2, 3 axes each direction, 3 times each
MassApprox. 115 g
Part Number
H7HP-AD
Part NumberStandard Unit PriceMinimum order quantityVolume DiscountDays to ShipRoHSDisplay Digits Power Supply Voltage Power supply voltage details
(V)
Color

SGD 351.55

1 Piece(s) 67 Day(s) -6 digitsDedicated to DCDC 12–24Light Gray

Loading...

  1. 1
 

Basic Information

Type Total counter Display method LCD Count input (CH = N) 2
Mounting Method Panel Panel cut dimensions 68x33 Output NA
Prescale NA Representative Standard CE / UL / CSA Dimension vertical(mm) 36
Dimension width(mm) 72 Dimension depth(mm) 65.8 Classification Total counter/time counter
MAX input frequency (MAX counting speed) (Hz) 30Hz/5kHz Computing Method Add-subtract/multiply Power outage recording function Available
Protective Structure IP66 oil resistant type

Please check the type/dimensions/specifications of the part H7HP-AD in the Total counter/Time counter (DIN72 × 36) H7HP series.

Similar Part Numbers

Part Number
H7HP-A
H7HP-ADB
H7HP-C8
H7HP-C8D
Part NumberStandard Unit PriceMinimum order quantityVolume DiscountDays to ShipRoHSDisplay Digits Power Supply Voltage Power supply voltage details
(V)
Color

SGD 318.23

1 Piece(s) Same day -6 digitsAC-dedicatedAC 100–240Light Gray

SGD 349.85

1 Piece(s) Same day -6 digitsDedicated to DCDC 12–24Black

SGD 367.84

1 Piece(s) 67 Day(s) 108 digitsAC-dedicatedAC 100–240Light Gray

SGD 330.33

1 Piece(s) Same day -8 digitsDedicated to DCDC 12–24Light Gray