Solid-state Timer H3CR-F / -G / -H (H3CR-G8L AC200-240)

Solid-state Timer H3CR-F / -G / -H H3CR-G8L AC200-240
  • On Sale Till 31/03/2025

[Features]
· A series based on twin timer, star delta timer.
· UL, CSA, LR, NK, CCC acquired, EN61812-1 compatible safe design.
· Compatible with the CE mark.
· Because the time units enable separate ON time and OFF time setting, combinations of long term ON or OFF and short time ON or OFF are possible.
· Product line-up with the two types of operational mode of start flicker ON and start flicker OFF.
· Power sources for any low voltage (AC24 to 48/DC12 to 48V), any high voltage (AC100 to 240V/DC100 to 125V).
· 24 types of time ranges can be selected from among 0.05 seconds to 300 hours.
· Instantaneous output of 0 setting is possible.
· Because there is instantaneous output by revolving the scale in the direction of 0, the checking of the sequence operation and the like is simple.
· UL, CSA, NK, LR, CCR acquired, EN61812-1 compatible.
· Corresponds to the CE mark.

PDF

Japanese Only

Part Number

Configured Part Number is shown.

H3CR-G8L AC200-240

Solid-State Timer Specifications

Catalog product
H3CR-F /-G / -H external appearance

H3CR-F /-G / -H external appearance

Series H3CR-F Twin Timer Performance

Because the time units enable separate ON time and OFF time setting, combinations of long term ON or OFF and short time ON or OFF are possible.
Product range includes 2 types of operational modes: start flicker ON and start flicker OFF.
Power supplies for low voltage (24 to 48 V AC / 12 to 48 V DC) and high voltage (100 to 240 V AC / 100 to 125 V AC) can be freely selected.
24 types of time ranges can be selected, from 0.05 seconds to 300 hours.
Instantaneous output for zero set value is possible. There is instantaneous output by turning the scale in the 0 direction, making it easy to confirm sequence operations, etc.
Complies with UL, CSA, NK, LR, and CCC, and is EN61812-1 compliant. Conforms to the CE mark.

H3CR-G Star Delta Timer Performance

4 types of time ranges can be selected with a single device, from 0.5 seconds to 120 seconds.
Complies with UL, CSA, NK, and LR, and is EN61812-1 compliant. Conforms to CE mark, CCC*
*Series H3CR-G8L-30/-G8EL-31 are not compliant with safety standards.

Series H3CR-H Power Supply OFF Delay Timer

4 types of time ranges can be selected for each series, from 0.05 seconds to 12 seconds for the S series and from 0.05 minutes to 12 minutes for the M series.
Complies with UL, CSA, NK, and LR, and is EN61812-1 compliant. Conforms to CE mark, CCC.

Solid-State Timer Performance

Variations In Operating Time±0.2% (percentage relative to maximum scale) or less (±0.2%, ±10 ms or less in the 1.2‑s, 3‑s range)
Set Error±5% (percentage relative to maximum scale) ±50 ms or less
Recovery Time0.1 s Or Less
Voltage Effect±0.2% (percentage relative to maximum scale) or less (±0.2%, ±10 ms or less in the 1.2‑s, 3‑s range)
Temperature Effect±1% (percentage relative to maximum scale) or less (±1%, ±10 ms or less in the 1.2‑s, 3‑s range)
Insulation Resistance100 MΩ or more (at 500 V DC megger)
Withstand Voltage2,000 V AC, 50/60 Hz, 1 min (between charging metal part and non-charging metal part)
2,000 V AC, 50/60 Hz, 1 min (between control output and operation circuit)
2,000 V AC, 50/60 Hz, 1 min (between different pole contacts)
1,000 V AC, 50/60 Hz, 1 min (between discontinuous contacts)
Impulse Voltage5 kV (between power supply terminals); however, 1 kV for 24 to 48 V AC / 12 to 48 V DC types
5 kV (between conductive part terminal and exposed non-charging metal part)
However, 1.5 kV for 24 to 48 V AC / 12 to 48 V DC types
Noise ResistanceSquare-wave noise by noise simulator (pulse width 100 ns/1 μs rise 1 ns)
±1.5 kV (between power supply terminals)
Electrostatic Strength8 kV (Malfunction) 15 kV (Destruction)
VibrationEndurance10 to 55 Hz, half amplitude 0.75 mm, 3 directions, 2 h each
Malfunction10 to 55 Hz, half amplitude 0.5 mm, 3 directions, 10 min each
ShockEndurance980 m/s2, 6 directions, 3 times each
Malfunction98 m/s2, 6 directions, 3 times each
LifeMechanical20 million operations or more (no load, switching frequency 1,800 operations/h)
Electrical100,000 operations or more (250 V AC, 5 A, resistive load, switching frequency 1,800 operations/h)*
Protection StructureIP40 (Panel Surface)
MassApprox. 100 g

Solid-State Timer External Shape And Dimensional Drawing

Series H3CR-F, H3CR-FN external shape

Series H3CR-F, H3CR-FN external shape

Series H3CR-F, H3CR-FN dimensional drawing

Series H3CR-F, H3CR-FN dimensional drawing

  • *Refer to the catalog for external shapes and dimensional drawings for model numbers other than those listed above.
Part Number
H3CR-G8L AC200-240
Part NumberStandard Unit PriceMinimum order quantityVolume DiscountDays to ShipTime specifications
(s)
Power Supply Voltage Dimension depth
(mm)
Rated power supply voltage
(V)

SGD 101.30

SGD 20.26

1 Piece(s) Same day 0.4~120sAC-dedicated63.7AC200 to 240

Loading...

  1. 1
 

Basic Information

Type Timer Display method Analog Mounting Method Panel / surface mount (shared)
Output Method Relay Dimension vertical(mm) 48 Dimension width(mm) 48
Time ranges = N 24 range Contact Configuration 2c

Please check the type/dimensions/specifications of the part H3CR-G8L AC200-240 in the Solid-state Timer H3CR-F / -G / -H series.

Similar Part Numbers

Part Number
H3CR-F8 AC24-48/DC12-48
H3CR-F8N AC100-240/DC100-125
H3CR-F8N AC24-48/DC12-48
H3CR-G8L-30 AC100-120
H3CR-G8L-30 AC200-240
H3CR-H8L AC/DC24 M
Part NumberStandard Unit PriceMinimum order quantityVolume DiscountDays to ShipTime specifications
(s)
Power Supply Voltage Dimension depth
(mm)
Rated power supply voltage
(V)

SGD 117.85

1 Piece(s) 33 Day(s) 0.05s to 300hAC/DC52.3AC24 to 48/DC12 to 48

SGD 114.35

1 Piece(s) 4 Day(s) or more 0.05s to 300hAC/DC52.3AC100 to 240/DC100 to 125

SGD 119.55

1 Piece(s) Same day 0.05s to 300hAC/DC52.3AC24 to 48/DC12 to 48

SGD 107.57

1 Piece(s) 4 Day(s) or more 0.4~120sAC-dedicated63.7AC100 to 120

SGD 113.74

1 Piece(s) 4 Day(s) or more 0.4~120sAC-dedicated63.7AC200 to 240

SGD 104.20

1 Piece(s) 31 Day(s) 0.05~12minAC/DC63.7AC/DC24

Tech Support

Factory Automation, Electronics, Tools, & MRO (Maintenance, Repair and Operations)
Tel:(65) 6733 7211 / FAX:(65) 6733 0211
9:00am - 6:00pm (Monday - Friday)