(!)Due to Microsoft's end of support for Internet Explorer 11 on 15/06/2022, this site does not support the recommended environment.
Instead, please kindly use other browsers like Google Chrome, Microsoft Edge or Mozilla Firefox.
A wide variety of standard and configurable components for factory automation engineers in industries such as automotive, semiconductor, packaging, medical and many more.
A good selection of accessories such as screws, bolts, washers and nuts that you may need for your daily engineering usage.
Browse industrial materials ranging from heat insulating plates, sponges, to metal and plastic materials in different sizes to meet your various applications.
A wide variety of wiring parts for connecting and protecting control and PC parts including Connectors, Cables, Electric Wires, Crimping Terminals and more.
A wide variety of controls and PC parts for electrical engineers including Controls, Powers, PC parts and more.
A wide variety of cutting tools for many uses and work materials including End Mills, Drills, Cutters, Reamers, Turning Tools and more.
A wide variety of tools and supplies used in processing including Machine Tools, Measurement Tools, Grinding and Polishing Supplies and more.
A wide variety of goods used in shipment, material handling and warehouse including Tape supplies, Stretch film, Truck, Shelf, Crane and more.
A large variety of goods for every kind of factories and offices including Protection items, Cleaning supplies, sanitations, office supplies and more.
A large variety of items used in R&D and Clean Room including research Equipment, Laboratory Essentials, Analysis Supplies, Clean Environment-Related Equipment and more.
Choose from thousands of standard stamping die components including Punch & Die, Gas Springs, Guide Components, Coil Springs and many more.
Browse our wide variety of mold components including Ejector Pins, Sleeves, Leader Components, Sprue Bushings and many more.
Browse our injection molding components including Heating Items, Couplers, Hoses and more.
A small 2-pole, 2 A class signal switching type signal relay.
[Features]
・ Surface mount type 2-pole signal switching relay with terminals protruding from the side
・ Achieves high withstand voltage 2,000 V AC and high impact withstand voltage 2,500 V 2 × 10 μs (Telcordia standard) between coil contacts
・ Small size with height 9.4 mm × width 7.5 mm × length 15 mm
・ Achieves high sensitivity with rated power consumption of 140 mW
・ Compliant with IRS mounting method by using heat-resistant material
・ Obtained UL/CSA standard in standard format
・ Added series of terminal type for PCBs (type G65-2)
・ EN60950 certified type is also available (-Y type)
[Applications]
・ Mounted on PCB for communication equipment, office equipment, etc., and is used in a wide range of applications
Japanese Only
Part Number
Configured Part Number is shown.
G6S-2/G6S-2-Y external appearance
G6S-2/G6S-2-Y dimensional outline drawing
Units: mm
The general dimensional tolerance is ±0.3 mm.
PCB processing dimensions
Units: mm
The general dimensional tolerance is 0.3 mm.
G6SK-2 external appearance
G6SK-2 dimensional outline drawing
Units: mm
The general dimensional tolerance is ±0.3 mm.
PCB processing dimensions
Units: mm
The general dimensional tolerance is 0.3 mm.
G6SU-2 external appearance
G6SU-2 dimensional outline drawing
Units: mm
The general dimensional tolerance is ±0.3 mm.
PCB processing dimensions
Units: mm
The general dimensional tolerance is ±0.3 mm.
Classification | Items | Rated Current (mA) | Coil Resistance (Ω) | Operating Voltage (V) | Release Voltage (V) | Maximum Allowable Voltage (V) | Power Consumption (mW) | |
---|---|---|---|---|---|---|---|---|
Rated Voltage (V) | ||||||||
Model G6S-2 | DC | 4.5 | 31 | 145 | 75% or Less | 10% or More | 200% (23°C) | Approx. 140 |
5 | 28.1 | 178 | ||||||
12 | 11.7 | 1,028 | ||||||
24 | 8.3 | 2,880 | 170% (23°C) | Approx. 200 | ||||
Model G6S-2-Y | DC | 12 | 16.7 | 720 | 75% or Less | 10% or More | 170% (23°C) | Approx. 200 |
24 | 9.6 | 2,504 | Approx. 230 |
Classification | Items | Rated Current (mA) | Coil Resistance (Ω) | Set Voltage (V) | Reset Voltage (V) | Maximum Allowable Voltage (V) | Power Consumption (mW) | |
---|---|---|---|---|---|---|---|---|
Rated Voltage (V) | ||||||||
Model G6SK-2 | DC | 5 | 40 | 125 | 75% or Less | 75% or Less | 170% (23°C) | Approx. 200 |
12 | 16.7 | 720 |
Classification | Items | Rated Current (mA) | Coil Resistance (Ω) | Set Voltage (V) | Reset Voltage (V) | Maximum Allowable Voltage (V) | Power Consumption (mW) | |
---|---|---|---|---|---|---|---|---|
Rated Voltage (V) | ||||||||
Model G6SU-2 | DC | 3 | 33.3 | 90 | 75% or Less | 75% or Less | 180% (23°C) | Approx. 100 |
Load | Resistance Load |
---|---|
Rated Load | 125 V AC 0.5 A, 30 V DC 2 A |
Rated Conduction Current | 2 A |
Maximum Contact Voltage Value | 250 V AC, 220 V DC |
Maximum Contact Current Value | 2 A |
Type | Single Stable Type Model G6S-2 | Single Coil Latching Type Model G6SU-2 | Dual Coil Latching Type Model G6SK-2 | Single Stable Type Model G6S-2-Y | |
---|---|---|---|---|---|
Contact Resistance *1 | 75 mΩ or Less | ||||
Operation (Set) Time *2 | 4 ms or Less (Approx. 2.5 ms) | 4 ms or Less (Approx. 2 ms) | 4 ms or Less (Approx. 2.5 ms) | ||
Recovery (Reset) Time *2 | 4 ms or Less (Approx. 1.5 ms) | 4 ms or Less (Approx. 2 ms) | 4 ms or Less (Approx. 1.5 ms) | ||
Minimum Set/Reset Pulse Width | - | 10 ms | - | ||
Insulation Resistance *3 | 1,000 MΩ or More (with 500 V DC Megohmmeter) | ||||
Withstand Voltage | Between Coil and Contact | 2,000 V AC 50/60 Hz 1 min | 1,000 V AC 50/60 Hz 1 min | 2,000 V AC 50/60 Hz 1 min | |
Between Contacts of Different Polarities | 1,500 V AC 50/60 Hz 1 min | ||||
Between Contacts of Same Polarity | 1,000 V AC 50/60 Hz 1 min | ||||
Between Set/Reset Coils | - | 500 V AC 50/60 Hz 1 min | - | ||
Insulation Distance | Between Coil and Contact | Space: 1 mm, Creepage: 1.5 mm | Space: 2 mm, Creepage: 2 mm | ||
Impulse Withstand Voltage | Between Coil and Contact | 2,500 V 2 ×10 μs, 1,500 V 10 × 160 μs | 1,500 V 10 × 160 μs | 2,500 V 2 ×10 μs, 1,500 V 10 × 160 μs | |
Between Contacts of Different Polarities | 2,500 V 2 × 10 μs, 1,500 V 10 × 160 μs | ||||
Between Contacts of Same Polarity | 1,500 V 10 × 160 μs | ||||
Vibration | Durability | 10 to 55 to 10 Hz, Semi Amplitude 2.5 mm (Double Amplitude 5 mm) | |||
Malfunction | 10 to 55 to 10 Hz, Semi Amplitude 1.65 mm (Double Amplitude 3.3 mm) | ||||
Shock / Impact | Durability | 1,000 m/s2 | |||
Malfunction | 750 m/s2 | ||||
Durability | Mechanical | 100,000,000 Times or More (Switching Frequency: 36,000 Times/h) | |||
Electrical | AC 100,000 Times or More (Rated Load, Switching Frequency: 1,800 Times/h) DC 100,000 Times or More (Rated Load, Switching Frequency: 1,200 Times/h) | ||||
Failure Rate P Level (Reference Value *4) | DC 10 mV 10 μA | ||||
Ambient Operating Temperature | -40 to +85°C (Assuming No Freezing or Condensation), Dual Coil Latching Type 24 V DC Specification and Y Type 24 V DC Specification Only -40 to +70°C (Assuming No Freezing or Condensation) | ||||
Operating Ambient Humidity | 5 to 85%RH | ||||
Weight | Approx. 2 g |
*1. Measurement conditions: 1 V DC, 10 mA, voltage drop method.
*2. The values within ( ) are the actual values.
*3. Measurement conditions: Measuring the same spot for the withstand voltage items using a 500 V DC insulation resistance meter. (Except between set and reset coils)
*4 This value is obtained with a switching frequency of 120 times/min. and a contact resistance failure value of 50 Ω. These values may vary depending on switching frequency and operating conditions, meaning it is always recommended to double-check under actual load conditions.
Part Number |
---|
G6S-2 DC4.5 |
G6S-2 DC5 |
G6S-2 DC12 |
G6S-2 DC24 |
G6S-2-Y DC12 |
G6S-2-Y DC24 |
G6SK-2 DC12 |
Part Number | Standard Unit Price | Minimum order quantity | Volume Discount | Days to Ship | Latch function | Coil rated voltage (DC) (V) | Safety standards | Classification |
---|---|---|---|---|---|---|---|---|
SGD 7.59 SGD 1.52 | 1 Piece(s) | Same day | NA | 4.5 | - | Single stable shape | ||
SGD 11.98 SGD 2.40 | 1 Piece(s) | Same day | NA | 5 | - | Single stable shape | ||
SGD 11.98 SGD 2.40 | 1 Piece(s) | Same day | NA | 12 | UL / CSA | Single stable shape | ||
SGD 5.60 | 1 Piece(s) | Quote | NA | 24 | UL / CSA | Single stable shape | ||
SGD 8.04 SGD 1.61 | 1 Piece(s) | Same day | NA | 12 | - | Single stable shape | ||
SGD 9.25 SGD 1.85 | 1 Piece(s) | Same day | NA | 24 | - | Single stable shape | ||
SGD 5.80 | 1 Piece(s) | Quote | Available | 12 | - | 2-winding latching type |
Loading...
Application | For Signals | Contact Configuration | 2c | Terminal shape | For Circuit Boards |
---|---|---|---|---|---|
Contact rated current (minimum value for AC and DC)(A) | 0.5 | Dimension height(mm) | 9.2 | Dimension width(mm) | 14.8 |
Dimension depth(mm) | 7.3 | Protective Structure | Plastic seal type | Contact mechanism | Crossbar twin |
Circuit Board Mounting | Circuit Board Hole Insertion | AC rated load(V)/(A) | AC125/0.5 | DC rated load(V)/(A) | DC30/2 |
How can we improve?
How can we improve?