(!)Due to Microsoft's end of support for Internet Explorer 11 on 15/06/2022, this site does not support the recommended environment.
Instead, please kindly use other browsers like Google Chrome, Microsoft Edge or Mozilla Firefox.

  • Scheduled Maintenance Notice: This site will be unavailable due to scheduled maintenance from 9:00 24/11/2024 to 7:00 (SGT) 25/11/2024. We apologize for the inconvenience.
  • Notice of End of Sales for Economy Series Pneumatic Equipment Category. More information.

Surface-mount Relay - G6J-Y

Surface-mount Relay - G6J-Y
  • On Sale Till 31/03/2025

[Features]
· An ultra-small two-pole slim relay.
· Supports high-density mounting (width: 5.7 mm × length: 10.6 mm × height: 9 mm).
· Features a high withstand voltage between coil-contacts of AC1,500V. Also has an impulse withstand voltage of 2.5kV2 × 10 μs (supports Telcordia standards).
· FCCpart68 (1,5kV10, 10 × 160 μs) compliant for between coil-contacts and between identical polarity contacts.
· The series also includes single coiled wire latching types, supporting power saving measures.
· The standard type is UL and CSA standard certified.

PDF

Japanese Only

Part Number

Configured Part Number is shown.

G6J-2P-Y DC12

Surface Mount Relay (PCB Terminal Type) Specifications

Surface Mount Relay G6J-Y: related images

 

G6J-2P-Y external appearance

  • Units: mm
  • The general dimensional tolerance is ±0.3 mm.

 

Surface Mount Relay G6J-Y: related images

 

G6J-2P-Y dimensional outline drawing

  • Units: mm
  • The general dimensional tolerance is ±0.3 mm.

 

Surface Mount Relay G6J-Y: related images

 

PCB processing dimensions

  • Units: mm
  • The dimensional tolerance is ±0.1 mm.

 

Ratings/Performance

International Standard Certification Rating

UL/C-UL standards certified type (File No. E41515)

Number of ContactsOperating Coil RatingContact RatingNumber of Times Tested
2cModel G6J-2P-Y1 A 30 V DC 40°C
0.5 A 60 V DC 40°C
0.3 A 125 V AC 40°C
6,000

Ratings

Operating Coil/Single Stable Type (G6J-2P-Y)

ItemsRated Current
(mA)
Coil Resistance
(Ω)
Operating Voltage
(V)
Release Voltage
(V)
Maximum Allowable Voltage
(V)
Power Consumption
(mW)
Rated Voltage (V)
DC528.9173.175% or Less10% or More150%Approx. 140
1212.3976.8
249.22,600.5Approx. 230

*1: The rated current and coil resistance are measured at a coil temperature of 23°C and a tolerance of ±10%.
Note 2: The operating characteristics are measured at a coil temperature of +3°C.
*3: The maximum allowable voltage is the maximum voltage that can be applied to a relay coil.

Switching Part (Contact Part)

LoadResistance Load
Rated Load125 V AC 0.3 A
30 V DC 1 A
Rated Conduction Current1 A
Maximum Contact Voltage Value125 V AC, 110 V DC
Maximum Contact Current Value1 A

Performance

TypeSingle Stable Type
ModelModel G6J-2P-Y
Contact Resistance *1100 mΩ or Less
Operation (Set) Time *23 ms or Less (Approx. 1.6 ms)
Recovery (Reset) Time *23 ms or Less (Approx. 1.0 ms)
Minimum Set/Reset Pulse Width-
Insulation Resistance *31,000 MΩ or More (at 500 V DC)
Withstand VoltageBetween Coil and Contact1,500 V AC 50/60 Hz 1 min
Between Contacts of Different Polarities1,000 V AC 50/60 Hz 1 min
Between Contacts of Same Polarity750 V AC 50/60 Hz 1 min
Impulse Withstand VoltageBetween Coil and Contact2,500 V 2 × 10 μs
Between Contacts of Different Polarities1,500 V 10 × 160 μs
Between Contacts of Same Polarity
VibrationDurability10 to 55 to 10 Hz, Semi Amplitude 2.5 mm (Double Amplitude 5 mm)
Malfunction10 to 55 to 10 Hz, Semi Amplitude 1.65 mm (Double Amplitude 3.3 mm)
Shock / ImpactDurability1,000 m/s2
Malfunction750 m/s2
DurabilityMechanical50,000,000 Times or More (Switching Frequency: 36,000 Times/h)
Electrical100,000 Times or More (Rated Load, Switching Frequency: 1,800 Times/h)
Failure Rate P Level (Reference Value *4)DC 10 mV 10 μA
Ambient Operating Temperature-40 to +85°C (Assuming No Freezing or Condensation)
Operating Ambient Humidity5 to 85%RH
WeightApprox. 1.0 g

*The above values are the initial default values.

*1. Measurement conditions: 1 V DC 10 mA, voltage drop method.
*2. The values within ( ) are the actual values.
*3. Measurement conditions: Measuring the same spot for the withstand voltage items using a 500 V DC insulation resistance meter.
*4. This value is obtained with a switching frequency of 120 times/min. and a contact resistance failure value of 50 Ω. These values may vary depending on switching frequency and operating conditions, meaning it is always recommended to double-check under actual load conditions.

Part Number
G6J-2P-Y DC12
Part NumberStandard Unit PriceMinimum order quantityVolume DiscountDays to Ship

SGD 8.80

SGD 1.76

1 Piece(s) Same day

Loading...

  1. 1
 

Basic Information

Application For Signals Contact Configuration 2c Latch function NA
Terminal shape For Circuit Boards Contact rated current (minimum value for AC and DC)(A) 0.3 Coil rated voltage (DC)(V) 12
Dimension height(mm) 10 Dimension width(mm) 10.6 Dimension depth(mm) 5.7
Classification Single stable shape Protective Structure Plastic seal type Contact mechanism Crossbar twin
Circuit Board Mounting Circuit Board Hole Insertion AC rated load(V)/(A) AC125/0.3 DC rated load(V)/(A) DC30/1

Please check the type/dimensions/specifications of the part G6J-2P-Y DC12 in the Surface-mount Relay - G6J-Y series.

Tech Support

Factory Automation, Electronics, Tools, & MRO (Maintenance, Repair and Operations)
Tel:(65) 6733 7211 / FAX:(65) 6733 0211
9:00am - 6:00pm (Monday - Friday)