A wide variety of standard and configurable components for factory automation engineers in industries such as automotive, semiconductor, packaging, medical and many more.
A good selection of accessories such as screws, bolts, washers and nuts that you may need for your daily engineering usage.
Browse industrial materials ranging from heat insulating plates, sponges, to metal and plastic materials in different sizes to meet your various applications.
A wide variety of wiring parts for connecting and protecting control and PC parts including Connectors, Cables, Electric Wires, Crimping Terminals and more.
A wide variety of controls and PC parts for electrical engineers including Controls, Powers, PC parts and more.
A wide variety of cutting tools for many uses and work materials including End Mills, Drills, Cutters, Reamers, Turning Tools and more.
A wide variety of tools and supplies used in processing including Machine Tools, Measurement Tools, Grinding and Polishing Supplies and more.
A wide variety of goods used in shipment, material handling and warehouse including Tape supplies, Stretch film, Truck, Shelf, Crane and more.
A large variety of goods for every kind of factories and offices including Protection items, Cleaning supplies, sanitations, office supplies and more.
A large variety of items used in R&D and Clean Room including research Equipment, Laboratory Essentials, Analysis Supplies, Clean Environment-Related Equipment and more.
Choose from thousands of standard stamping die components including Punch & Die, Gas Springs, Guide Components, Coil Springs and many more.
Browse our wide variety of mold components including Ejector Pins, Sleeves, Leader Components, Sprue Bushings and many more.
Browse our injection molding components including Heating Items, Couplers, Hoses and more.
Unbeatable ease-of-use combined with economy.
[Features]
· Changing each digit up/down is a simple operation with a see-saw key.
· Simplified "digitization" of an analog timer.
· Timer, twin timer implement in one apparatus.
· Power source circuit and input circuit are isolated from each other in the timer.
· An upper limit of the setting value can be set, preventing mis-operation by the output apparatus due to erroneous setting.
· Contributes to estimation of lifetime of the timer and load with the output time counter.
· A line-up with an instantaneous connection point type.
· Water resistant/dust resistant structure (UL 508 Type 4X: IP66).
· Implements a key protect function.
Japanese Only
Part Number
Configured Part Number is shown.
H5CZ external appearance
Excellent operability
Operation is simple, just press the Up/Down key for each digit.
Advantages of "digitizing" an analog timer.
With digitization, precision is improved and the elapsed time can be displayed. Products with an instantaneous contact are also available.
Insulated separation of the power supply and input circuit
The power supply circuit and input circuit are isolated from each other in the timer.
Conventional non-insulated timers have constraints on wiring such as prohibiting grounding of the input 0 V line, etc., and if there are errors in the wiring the timer will fail, but the H5CZ is secure.
*H5CZ 100 to 240 V AC specifications
Setting value limit function
An upper limit for the setting value can be set, preventing unexpected operation by the output apparatus due to erroneous setting.
Number of outputs counting function
The number of times output is turned ON is cumulatively counted (alarm display, number of times can be monitored, units of 1,000). Contributes to estimation of the timer and load life.
Products with an instantaneous contact are also available
Types with an instantaneous contact that can be used as a self-hold circuit or auxiliary relay are also available. Convenient replacement for an analog timer.
Waterproof / dust-proof structure (UL508 Type 4X: IP66)
Can be used safely even in areas with water.
Note: When using waterproof packing Y92S-29.
Implementation of a key protect function
7 patterns can be selected. Can be set to match the usage situation.
Variations In Operating Time, Set Errors (Including Temperature And Voltage Effects) | ±0.01% ±0.05 s or less (for power supply start)* ±0.005% ±0.03 s or less (for signal start)* For power supply start, if the set value is set within the sensor wait time, output will not turn ON even if the set time has elapsed, and it will turn ON once the sensor wait time is completed. * Percentage relative to set value | |
---|---|---|
Insulation Resistance | 100 MΩ or more (at 500 V DC megger) Between the conductive part terminal and exposed non-charging metal part, between discontinuous contacts | |
Withstand Voltage | Between charging metal part and non-charging metal part: 2,000 V AC, 50/60 Hz, 1 min Between power supply and input circuit: 2,000 V AC, 50/60 Hz, 1 min (excluding H5CZ-□D) Between control output and power supply, input circuit: 2,000 V AC, 50/60 Hz, 1 min Between discontinuous contacts: 1,000 V AC, 50/60 Hz, 1 min | |
Impulse Voltage | Between power supply terminals: 5 kV (24 V AC / 12 to 24 V DC types are 1.0 kV) Between the conductive part terminal and exposed non-charging metal part: 5 kV (24 V AC / 12 to 24 V DC types are 1.5 kV) | |
Noise Resistance | Between power supply terminals: ±1.5 kV Between input terminals: ±600 V Square-wave noise by noise simulator (pulse width 100 ns/1 μs, rise 1 ns) | |
Electrostatic Strength | 8 kV (Malfunction), 15 kV (Destruction) | |
Vibration | Endurance | 10 to 55 Hz, half amplitude 0.75 mm, 3 directions, 2 h each |
Malfunction | 10 to 55 Hz, half amplitude 0.35mm, 3 directions, 10 min each | |
Shock | Endurance | 300 m/s2, 3 axes each direction, 3 times each |
Malfunction | 100 m/s2, 3 axes each direction, 3 times each | |
Life | Mechanical | 10 million operations or more (no load, switching frequency 1,800 operations/h, ambient temperature conditions: 23°C) |
Electrical | 100,000 operations or more (250 V AC, 5 A, resistive load, 1,800 operations/h, ambient temperature conditions: 23°C) | |
Mass | Approx. 105 g (Main Body Only) |
Part Number |
---|
H5CZ-L8 |
H5CZ-L8D |
H5CZ-L8E |
H5CZ-L8ED |
Part Number | Standard Unit Price | Minimum order quantity | Volume Discount | Days to Ship | Power Supply Voltage | Rated power supply voltage (V) | Contact Configuration |
---|---|---|---|---|---|---|---|
SGD 79.30 | 1 Piece(s) | Same day | AC-dedicated | AC 100–240 | Time Limit 1c | ||
SGD 79.30 | 1 Piece(s) | Same day | AC/DC | AC24/DC12 to 24 | Time Limit 1c | ||
SGD 111.86 | 1 Piece(s) | 4 Day(s) or more | AC-dedicated | AC 100–240 | Time limit 1c + instant 1c | ||
SGD 118.29 | 1 Piece(s) | 16 Day(s) | AC/DC | AC24/DC12 to 24 | Time limit 1c + instant 1c |
Loading...
Type | Timer | Display method | Liquid Crystal | Time specifications(s) | 0.001s to 9999h |
---|---|---|---|---|---|
Output Method | Relay | Representative Standard | CE / UL / CUL / CCC | Dimension vertical(mm) | 48 |
Dimension width(mm) | 48 | Dimension depth(mm) | 83.9 | Time ranges = N | 10 range |
Terminal shape | Plug-in terminal | Digits = N (counter) | 4 digits | Pre-scale function (counter) | × |
Input mode (counter) | Addition/deduction |