(!)Due to Microsoft's end of support for Internet Explorer 11 on 15/06/2022, this site does not support the recommended environment.
Instead, please kindly use other browsers like Google Chrome, Microsoft Edge or Mozilla Firefox.
A wide variety of standard and configurable components for factory automation engineers in industries such as automotive, semiconductor, packaging, medical and many more.
A good selection of accessories such as screws, bolts, washers and nuts that you may need for your daily engineering usage.
Browse industrial materials ranging from heat insulating plates, sponges, to metal and plastic materials in different sizes to meet your various applications.
A wide variety of wiring parts for connecting and protecting control and PC parts including Connectors, Cables, Electric Wires, Crimping Terminals and more.
A wide variety of controls and PC parts for electrical engineers including Controls, Powers, PC parts and more.
A wide variety of cutting tools for many uses and work materials including End Mills, Drills, Cutters, Reamers, Turning Tools and more.
A wide variety of tools and supplies used in processing including Machine Tools, Measurement Tools, Grinding and Polishing Supplies and more.
A wide variety of goods used in shipment, material handling and warehouse including Tape supplies, Stretch film, Truck, Shelf, Crane and more.
A large variety of goods for every kind of factories and offices including Protection items, Cleaning supplies, sanitations, office supplies and more.
A large variety of items used in R&D and Clean Room including research Equipment, Laboratory Essentials, Analysis Supplies, Clean Environment-Related Equipment and more.
Choose from thousands of standard stamping die components including Punch & Die, Gas Springs, Guide Components, Coil Springs and many more.
Browse our wide variety of mold components including Ejector Pins, Sleeves, Leader Components, Sprue Bushings and many more.
Browse our injection molding components including Heating Items, Couplers, Hoses and more.
Timer is shaped similarly to the H3Y, and supports multiple time ranges and operational modes.
[Features]
· EN61812-1 compatible, conforms to the CE mark.
· Supports multiple time ranges with switch-over between 4 ranges.
· Supports multiple operational modes providing 4 functions in 1 device.
· MY type relay and terminal compatible.
· Compatible with the EN standard, so OK for export to Europe.
· A semi-multi power supply voltage range greatly reduces the number of maintenance supplies kept in stock.
[Applications]
· The timer acts as control equipment, switching the output signal at the preset time after the start signal is input.
Japanese Only
Part Number
Configured Part Number is shown.
H3YN external appearance
Format | Series H3YN-2/-4 | Series H3YN-21/-41 | |
---|---|---|---|
Variations In Operating Time | ±1% or less (at maximum scale time) (±1% ±10 ms or less at 1 s range) | ||
Set Error | ±10% ±50 ms or less (at maximum scale time) | ||
Recovery Time | 0.1 s or less (including recovery during operation) | ||
Voltage Effect | ±2% or less (at maximum scale time) | ||
Temperature Effect | ±2% or less (at maximum scale time) | ||
Insulation Resistance | 100 MΩ or more (measurement at 500 V DC megger) | ||
Withstand Voltage | 2,000 V AC, 50/60 Hz, 1 min (between conductive part terminal and exposed non-charging metal part, excluding the terminal screw part) 2,000 V AC, 50/60 Hz, 1 min (between control output and operation circuit) 2,000 V AC, 50/60 Hz, 1 min (2-pole type between different pole contacts) 1,500 V AC, 50/60 Hz, 1 min (4-pole type between different pole contacts) 1,000 V AC, 50/60 Hz, 1 min (between discontinuous contacts) | ||
Vibration | Endurance | 10 to 55 Hz, half amplitude 0.75 mm, 3 directions, 1 h each | |
Malfunction | 10 to 55 Hz, half amplitude 0.5 mm, 3 directions, 10 min each | ||
Shock | Endurance | 1,000 m/s2, 6 directions, 3 times each*1 | |
Malfunction | 100m/s2, 6 directions, 3 times each | ||
Life | Mechanical | 10 million operations or more (no load, switching frequency 1,800 operations/h) | |
Electrical | 2-pole, 500,000 operations or more (250 V AC, 5 A, resistive load, switching frequency 1,800 operations/h) (room temperature) 4-pole, 200,000 operations (100,000 operations or more for -Z) or more (250 V AC, 3 A, resistive load, switching frequency 1,800 operations/h) (room temperature)*2 | ||
Impulse Voltage | 3 kV between power supply terminals; however, 1 kV for 12 V DC, 24 V DC, 48 V DC and 24 V AC, 4.5 kV between the conductive part terminal and exposed non-charging metal part; however, 1.5 kV for 12 V DC, 24 V DC, 48 V DC and 24 V AC | ||
Noise Resistance | Square-wave noise by noise simulator (pulse width 100 ns/1 μs rise 1 ns) ±1.5 kV | ||
Electrostatic Strength | 4 kV (Malfunction), 8 kV (Destruction) | ||
Protective Structure | IP40 | ||
Mass | Approx. 50g |
*1. Condition when carrying out impact resistance testing with the timer alone.
*2. Check the electrical life curve.
Series H3YN-2, H3YN-21 dimensional drawing A
Series H3YN-2, H3YN-21 dimensional drawing B
Series H3YN-2, H3YN-21 mounting hole processing dimensional drawing
Series H3YN-4, H3YN-41, H3YN-4-Z dimensional drawing A
Series H3YN-4, H3YN-41, H3YN-4-Z dimensional drawing B
Series H3YN-4, H3YN-41, H3YN-4-Z mounting hole processing dimensional drawing
Part Number |
---|
H3YN-21 AC100-120 |
H3YN-21 AC200-230 |
H3YN-21 DC12 |
H3YN-21 DC24 |
H3YN-41 AC100-120 |
H3YN-41 AC200-230 |
H3YN-41 DC24 |
Part Number | Standard Unit Price | Minimum order quantity | Volume Discount | Days to Ship | Type | Display method | Time specifications (s) | Power Supply Voltage | Rated power supply voltage (V) | Contact Configuration |
---|---|---|---|---|---|---|---|---|---|---|
SGD 67.80 | 1 Piece(s) | 31 Day(s) | Timer | Analog | 0.1 min – 10 h | AC-dedicated | AC100 to 120 | Time Limit 2c | ||
SGD 68.20 | 1 Piece(s) | 31 Day(s) | Timer | Analog | 0.1 min – 10 h | AC-dedicated | AC200 to 230 | Time Limit 2c | ||
SGD 53.22 | 1 Piece(s) | 4 Day(s) or more | Timer | Analog | 0.1 min – 10 h | Dedicated to DC | DC12 | Time Limit 2c | ||
SGD 62.32 | 1 Piece(s) | 4 Day(s) or more | Timer | Analog | 0.1 min – 10 h | Dedicated to DC | DC24 | Time Limit 2c | ||
SGD 68.12 | 1 Piece(s) | 4 Day(s) or more | Timer | Analog | 0.1 min – 10 h | AC-dedicated | AC100 to 120 | Time Limit 4c | ||
SGD 66.43 | 1 Piece(s) | 4 Day(s) or more | Timer | Analog | 0.1 min – 10 h | AC-dedicated | AC200 to 230 | Time Limit 4c | ||
SGD 64.61 | 1 Piece(s) | 4 Day(s) or more | Timer | Analog | 0.1 min – 10 h | Dedicated to DC | DC24 | Time Limit 4c |
Loading...
Output Method | Relay | Representative Standard | CE / UL / CCC / CSA | Dimension vertical(mm) | 28 |
---|---|---|---|---|---|
Dimension width(mm) | 21.5 | Dimension depth(mm) | 52.6 | Time ranges = N | 4 range |
Terminal shape | Plug-in terminal |
How can we improve?
How can we improve?