(!)Due to Microsoft's end of support for Internet Explorer 11 on 15/06/2022, this site does not support the recommended environment.
Instead, please kindly use other browsers like Google Chrome, Microsoft Edge or Mozilla Firefox.
A wide variety of standard and configurable components for factory automation engineers in industries such as automotive, semiconductor, packaging, medical and many more.
A good selection of accessories such as screws, bolts, washers and nuts that you may need for your daily engineering usage.
Browse industrial materials ranging from heat insulating plates, sponges, to metal and plastic materials in different sizes to meet your various applications.
A wide variety of wiring parts for connecting and protecting control and PC parts including Connectors, Cables, Electric Wires, Crimping Terminals and more.
A wide variety of controls and PC parts for electrical engineers including Controls, Powers, PC parts and more.
A wide variety of cutting tools for many uses and work materials including End Mills, Drills, Cutters, Reamers, Turning Tools and more.
A wide variety of tools and supplies used in processing including Machine Tools, Measurement Tools, Grinding and Polishing Supplies and more.
A wide variety of goods used in shipment, material handling and warehouse including Tape supplies, Stretch film, Truck, Shelf, Crane and more.
A large variety of goods for every kind of factories and offices including Protection items, Cleaning supplies, sanitations, office supplies and more.
A large variety of items used in R&D and Clean Room including research Equipment, Laboratory Essentials, Analysis Supplies, Clean Environment-Related Equipment and more.
Choose from thousands of standard stamping die components including Punch & Die, Gas Springs, Guide Components, Coil Springs and many more.
Browse our wide variety of mold components including Ejector Pins, Sleeves, Leader Components, Sprue Bushings and many more.
Browse our injection molding components including Heating Items, Couplers, Hoses and more.
Ultra-small timer for use in sequence control incorporating a dedicated IC.
[Features]
· Highly accurate with a repeat error of ±1% (including first time value).
· Recovery time including recovery during operation is 100 ms or less.
· Time is easily set using the large dial that works with either straight-slot or Phillips-head screwdrivers.
· Semi-multi power supply voltages.
· Standard product complies with UL and CSA standards.
· EN61812-1 compatible, conforms to the CE mark.
[Applications]
· Many facilities require timer functions, and this can be used anywhere on the line.
Japanese Only
Part Number
Configured Part Number is shown.
H3Y-2 AC24 60M
External appearance of H3Y
Maximum scale time | Time Setting Range |
---|---|
0.5 s | 0.04 s to 0.5 s |
1s | 0.1 s to 1.0 s |
5 s | 0.2 s to 5.0 s |
10 s | 0.5s to 10 s |
30 s | 1.0 s to 30 s |
60 s | 2.0 s to 60 s |
120 s | 5.0 s to 120 s |
3 min | 0.1 min to 3 min |
5 min | 0.2 min to 5 min |
10 min | 0.5 min to 10 min |
30 min | 1.0 min to 30 min |
60 min | 2.0 min to 60 min |
3 h | 0.1 h to 3 h |
Model number | Series H3Y-2 (-0) | Series H3Y-4 (-0) | |
---|---|---|---|
Power supply voltage *6 | ・ 100 to 120 V AC, 50/60 Hz, 200 to 230 V AC, 50/60 Hz ・ 24 V AC, 50/60 Hz *1 ・DC12V ・DC24V ・DC48V ・DC100 to 110 V ・DC125V *2, *3 | ||
Allowable voltage fluctuation range | 85 to 110% of power supply voltage (However, 90 to 110% of power supply voltage only for 12 V DC specifications) *4 | ||
Power consumption | AC100 to 120 V | 1.5 VA (at 120 V AC) | |
AC200 to 230 V | 1.8 VA (at 230 V AC) | ||
AC24V | 1.5 VA (at 24 V AC) | ||
DC12V | 0.9 W (at 12 V DC) | ||
DC24V | 0.9 W (at 24 V DC) | ||
DC48V | 1.0 W (at 48 V DC) | ||
DC100 to 110 V | 1.3 W (at 110 V DC) | ||
DC125V | 1.3 W (at 125 V DC) | ||
Reset voltage | 10% or more of power supply voltage *5 | ||
Control output | 250 V AC 5 A, resistant load (cosø = 1) Minimum compatible load 5 V DC 1 mA (P level, reference value) Contact Materials: Ag | 250 V AC 3 A, resistant load (cosø = 1) Minimum compatible load 1 V DC 1 mA (P level, reference value) Contact Materials: Au clad + Ag alloy | |
Operating Ambient Temperature | -10 to +50℃ (However, do not freeze) | ||
Storage temperature | -25 to +65℃ (However, do not freeze) | ||
Operating ambient humidity | 35 to 85% |
*1. The inverter output should not be used as a power supply.
*2. Single-phase, full-wave-rectified power supplies can be used.
*3. Only the H3Y-2 and H3Y-2-0 types include 12 V DC models.
* 4. When using continuously at an operating ambient temperature of 50°C, 90 to 110% of the power supply voltage (95 to 110% for 12 V DC) should be used.
* 5. For reliable reset, 100 to 120 V AC should be set to 10 V AC, 200 to 230 V AC should be set to 20 V AC, and 100 to 110 V DC should be set to 10 V DC or less.
*6. A diode to prevent reverse voltages is provided only on models with a DC power supply voltage.
Model number | Series H3Y-2 (-0) | Series H3Y-4 (-0) | |
---|---|---|---|
Accuracy of operating time | ±1% or less (at maximum scale time) *1 | ||
Setting error | ±10% ±50 ms max. (at maximum scale time) | ||
Reset time | 0.1 s max. (including halfway reset) | ||
Influence of voltage | ±2% or less (at maximum scale time) *1 | ||
Influence of temperature | ±2% or less (at maximum scale time) *1 | ||
Insulation resistance | 100 MΩ or more (Measured at 500 V DC insulation resistance tester) | ||
Withstand voltage | 2,000 V AC, 50/60 Hz for 1 min (Between current-carrying terminals and exposed non-current-carrying metal parts, except for the terminal thread section) 2,000 V AC, 50/60 Hz for 1 min (Between operating power supply circuit and control output) 2,000 V AC, 50/60 Hz for 1 min (Between different pole contacts; 2-pole model) 1,500 V AC 50/60 Hz 1 min (Between different pole contacts; 4-pole model) 1,000 V AC 50/60 Hz 1 min (Between non-continuous contacts) | ||
Impulse voltage | Between power supply terminals: 3 kV, 1 kV for 12 V DC, 24 V DC, 48 V DC Between exposed non-current-carrying metal parts: 4.5 kV, 1.5 kV for 12 V DC, 24 V DC, 48 V DC | ||
Noise immunity | Square-wave noise by noise simulator (pulse width: 100 ns/1 μs, 1-ns rise) ±1.5 kV | ||
Static immunity | Malfunction: 4 kV, Destruction: 8 kV | ||
Vibration | Destruction | 10 to 55 Hz, 0.75-mm single amplitude for 1 h each in 3 directions | |
Malfunction | 10 to 55 Hz, 0.5-mm single amplitude for 10 min each in 3 directions | ||
Impact | Destruction | 1,000 m/s^2 for 3 times each in 6 directions *2 | |
Malfunction | 100 m/s^2 for 3 times each in 6 directions | ||
Lifespan | Mechanical | 10,000,000 operations min. (under no load at 1,800 operations/h) | |
Electrical | 2-pole: 500,000 operations min. (250 V AC 5 A, resistant load at 1,800 operations/h) (At normal temperature) 4-pole: 200,000 operations min. (250 V AC 3 A, resistant load at 1,800 operations/h) (At normal temperature) | ||
Protective structure | IP40 | ||
Weight | Approx. 50 g |
*1. ±10 ms is added to the above value for the 0.5 s range model.
*2. The destructive impact resistance test was performed on the timer.
Part Number |
---|
H3Y-2 AC24 60M |
Part Number | Standard Unit Price | Minimum order quantity | Volume Discount | Days to Ship | RoHS | Type | Time specifications (s) | Power Supply Voltage | Rated power supply voltage (V) | Contact Configuration | Terminal shape |
---|---|---|---|---|---|---|---|---|---|---|---|
SGD 60.43 | 1 Piece(s) | 4 Day(s) or more | - | - | 2.0 m to 60 m | Dedicated to DC | AC24 | Time Limit 2c | Plug-in terminal |
Loading...
Display method | Analog | Output Method | Relay | Representative Standard | CE / UL / CCC / CSA |
---|---|---|---|---|---|
Dimension vertical(mm) | 52.6 | Dimension width(mm) | 28 | Dimension depth(mm) | 21.5 |
Time ranges = N | 1 range |
Please check the type/dimensions/specifications of the part H3Y-2 AC24 60M in the Solid State/Timer H3Y series.
Part Number |
---|
H3Y-2 AC100-120 120S |
H3Y-2 AC100-120 1S |
H3Y-2 AC100-120 30M |
H3Y-2 AC24 60S |
H3Y-2 DC100-110 0.5S |
H3Y-2 DC100-110 10M |
Part Number | Standard Unit Price | Minimum order quantity | Volume Discount | Days to Ship | RoHS | Type | Time specifications (s) | Power Supply Voltage | Rated power supply voltage (V) | Contact Configuration | Terminal shape |
---|---|---|---|---|---|---|---|---|---|---|---|
SGD 54.40 | 1 Piece(s) | 4 Day(s) or more | - | Timer | 5.0s to 120s | AC-dedicated | AC100 to 120 | Time Limit 2c | Plug-in terminal | ||
SGD 54.40 | 1 Piece(s) | 4 Day(s) or more | - | Timer | 0.1s to 1.0s | AC-dedicated | AC100 to 120 | Time Limit 2c | Plug-in terminal | ||
SGD 54.40 | 1 Piece(s) | 4 Day(s) or more | - | Timer | 1.0m to 30m | AC-dedicated | AC100 to 120 | Time Limit 2c | Plug-in terminal | ||
SGD 59.65 | 1 Piece(s) | 4 Day(s) or more | - | Timer | 2.0s to 60s | AC-dedicated | AC24 | Time Limit 2c | Plug-in terminal | ||
SGD 51.08 | 1 Piece(s) | 4 Day(s) or more | - | - | 0.04 s to 0.5 s | Dedicated to DC | DC100 to 110 | Time Limit 2c | Plug-in terminal | ||
SGD 45.18 | 1 Piece(s) | 4 Day(s) or more | - | Timer | 0.5m to 10m | Dedicated to DC | DC100 to 110 | Time Limit 2c | Plug-in terminal |
How can we improve?