A wide variety of standard and configurable components for factory automation engineers in industries such as automotive, semiconductor, packaging, medical and many more.
A good selection of accessories such as screws, bolts, washers and nuts that you may need for your daily engineering usage.
Browse industrial materials ranging from heat insulating plates, sponges, to metal and plastic materials in different sizes to meet your various applications.
A wide variety of wiring parts for connecting and protecting control and PC parts including Connectors, Cables, Electric Wires, Crimping Terminals and more.
A wide variety of controls and PC parts for electrical engineers including Controls, Powers, PC parts and more.
A wide variety of cutting tools for many uses and work materials including End Mills, Drills, Cutters, Reamers, Turning Tools and more.
A wide variety of tools and supplies used in processing including Machine Tools, Measurement Tools, Grinding and Polishing Supplies and more.
A wide variety of goods used in shipment, material handling and warehouse including Tape supplies, Stretch film, Truck, Shelf, Crane and more.
A large variety of goods for every kind of factories and offices including Protection items, Cleaning supplies, sanitations, office supplies and more.
A large variety of items used in R&D and Clean Room including research Equipment, Laboratory Essentials, Analysis Supplies, Clean Environment-Related Equipment and more.
Choose from thousands of standard stamping die components including Punch & Die, Gas Springs, Guide Components, Coil Springs and many more.
Browse our wide variety of mold components including Ejector Pins, Sleeves, Leader Components, Sprue Bushings and many more.
Browse our injection molding components including Heating Items, Couplers, Hoses and more.
[Features]
· Multiple time ranges and operational modes.
· DIN48 × 48 mm full multiple timer.
· Two types of AC / DC free power supply, drastically reducing the number of models in stock.
· Can deal with a variety of applications with eight operational modes (11 pin type) or five operational modes (8 pin type).
· An economical design with reduced power consumption.
· 0 Setting instantaneous output which facilitates sequence check.
· Socket (type P3G-08) attached, 75 mm neck-down short barrel type (Type H3CR-A8EAC100 to 240V/DC100 to 125V).
· PNP input types are also available in the lineup.
· UL, CSA, NK, LR, CCC acquired, EN61812-1 compatible, corresponds to the CE mark.
Japanese Only
Part Number
Configured Part Number is shown.
H3CR-A-302 DC24
H3CR-A external appearance
Features
An ecological design with reduced power consumption
Instantaneous zero setting output makes sequence checks easy
Socket (P3G-08) attached and body shortened to under neck 75 mm (H3CR-A8E, 100 to 240 V AC / 100 to 125 V DC)
PNP input type also available
Complies with UL, CSA, NK, LR, and CCC, EN61812-1 compatible, conforms to the CE mark.
Variations In Operating Time | ±0.2% (percentage relative to maximum scale) or less (±0.2%, ±10 ms or less in the 1.2‑s, 3‑s range) | |
---|---|---|
Set Error | ±5% (percentage relative to maximum scale) ±50 ms or less*1 | |
Recovery Time | 0.1 s Or Less | |
Voltage Effect | ±0.2% (percentage relative to maximum scale) or less (±0.2%, ±10 ms or less in the 1.2‑s, 3‑s range) | |
Temperature Effect | ±1% (percentage relative to maximum scale) or less (±1%, ±10 ms or less in the 1.2‑s, 3‑s range) | |
Insulation Resistance | 100 MΩ or more (at 500 V DC megger) | |
Withstand Voltage | 2,000 V AC, 50/60 Hz, 1 min (between charging metal part and non-charging metal part); however, -A□S type is 1,000 V AC 2,000 V AC, 50/60 Hz, 1 min (between control output and operation circuit); however, -A□S type is 1,000 V AC 2,000 V AC, 50/60 Hz, 1 min (between different pole contacts) 1,000 V AC, 50/60 Hz, 1 min (between discontinuous contacts) 2,000 V AC, 50/60 Hz, 1 min (between input and control output, operation circuit); however, -AP type only | |
Impulse Voltage | 5 kV (between power supply terminals) However, 24 to 48 V AC / 12 to 48 V DC, 24 to 48 V AC / V DC types are 1 kV 5 kV (between conductive part terminal and exposed non-charging metal part) However, 24 to 48 V AC / 12 to 48 V DC, 24 to 48 V AC / V DC types are 1.5 kV | |
Noise Resistance | Square-wave noise by noise simulator (pulse width 100 ns/1 μs rise 1 ns) ±1.5 kV; however, ±600 V between non-voltage input terminals | |
Electrostatic Strength | 8 kV (Malfunction) 15 kV (Destruction) | |
Vibration | Endurance | 10 to 55 Hz, half amplitude 0.75 mm, 3 directions, 2 h each |
Malfunction | 10 to 55 Hz, half amplitude 0.5 mm, 3 directions, 10 min each | |
Shock | Endurance | 1,000 m/s2, 6 directions, 3 times each |
Malfunction | 100 m/s, 6 directions, 3 times each | |
Life*2 | Mechanical | 20 million operations or more (no load, switching frequency 1,800 operations/h) |
Electrical | 100,000 operations or more (250 V AC, 5 A, resistant load, switching frequency 1,800 operations/h) | |
Protection Structure | IP40 (Panel Surface) | |
Mass | Approx. 90 g |
*1. When the C, D, and G mode signals of Series H3CR-AP are OFF, ±5% (percentage relative to maximum scale) +100 ms or less, -0 ms or less.
*2. Contact output only.
Series H3CR-A, H3CR-AP, H3CR-AS, H3CR-A-301 external shape
Series H3CR-A, H3CR-AP, H3CR-AS, H3CR-A-301 dimensional drawing
Series H3CR-A8, H3CR-A8S, H3CR-A8E, H3CR-A8-301 external shape
Series H3CR-A8, H3CR-A8S, H3CR-A8E, H3CR-A8-301 dimensional drawing
Part Number |
---|
H3CR-A-302 DC24 |
Part Number | Standard Unit Price | Minimum order quantity | Volume Discount | Days to Ship | Time specifications (s) | Output Method | Rated power supply voltage (V) | Time ranges = N | Contact Configuration |
---|---|---|---|---|---|---|---|---|---|
SGD 80.72 | 1 Piece(s) | 18 Day(s) | 0.05s to 300h | Relay | DC24 | 24 range | Time Limit 2c |
Loading...
Type | Timer | Display method | Analog | Power Supply Voltage | AC/DC |
---|---|---|---|---|---|
Representative Standard | CE / UL / CCC / CSA | Dimension vertical(mm) | 48 | Dimension width(mm) | 48 |
Dimension depth(mm) | 52.3 | Terminal shape | Plug-in terminal |
Please check the type/dimensions/specifications of the part H3CR-A-302 DC24 in the Solid State/Timer H3CR-A series.
Part Number |
---|
H3CR-A AC100-240/DC100-125 |
H3CR-A AC24-48/DC12-48 |
H3CR-A-301 AC100-240/DC100-125 |
H3CR-A8 AC100-240/DC100-125 |
H3CR-A8 AC24-48/DC12-48 |
H3CR-A8-301 AC100-240/DC100 |
Part Number | Standard Unit Price | Minimum order quantity | Volume Discount | Days to Ship | Time specifications (s) | Output Method | Rated power supply voltage (V) | Time ranges = N | Contact Configuration |
---|---|---|---|---|---|---|---|---|---|
SGD 59.50 | 1 Piece(s) | Same day | 0.05s to 300h | Relay | AC100 to 240/DC100 to 125 | 18 range | Time Limit 2c | ||
SGD 66.31 | 1 Piece(s) | Same day | 0.05s to 300h | Relay | AC24 to 48/DC12 to 48 | 18 range | Time Limit 2c | ||
SGD 80.72 | 1 Piece(s) | 4 Day(s) or more | 0.1s to 600h | Relay | AC100 to 240/DC100 to 125 | 18 range | Time Limit 2c | ||
SGD 52.50 | 1 Piece(s) | 31 Day(s) | 0.05s to 300h | Relay | AC100 to 240/DC100 to 125 | 18 range | Time Limit 2c | ||
SGD 55.30 | 1 Piece(s) | Same day | 0.05s to 300h | Relay | AC24 to 48/DC12 to 48 | 18 range | Time Limit 2c | ||
SGD 52.10 | 1 Piece(s) | 4 Day(s) or more | 0.1s to 600h | Relay | AC100 to 240/DC100 | 18 range | Time Limit 2c |
How can we improve?