(!)Due to Microsoft's end of support for Internet Explorer 11 on 15/06/2022, this site does not support the recommended environment.
Instead, please kindly use other browsers like Google Chrome, Microsoft Edge or Mozilla Firefox.
A wide variety of standard and configurable components for factory automation engineers in industries such as automotive, semiconductor, packaging, medical and many more.
A good selection of accessories such as screws, bolts, washers and nuts that you may need for your daily engineering usage.
Browse industrial materials ranging from heat insulating plates, sponges, to metal and plastic materials in different sizes to meet your various applications.
A wide variety of wiring parts for connecting and protecting control and PC parts including Connectors, Cables, Electric Wires, Crimping Terminals and more.
A wide variety of controls and PC parts for electrical engineers including Controls, Powers, PC parts and more.
A wide variety of cutting tools for many uses and work materials including End Mills, Drills, Cutters, Reamers, Turning Tools and more.
A wide variety of tools and supplies used in processing including Machine Tools, Measurement Tools, Grinding and Polishing Supplies and more.
A wide variety of goods used in shipment, material handling and warehouse including Tape supplies, Stretch film, Truck, Shelf, Crane and more.
A large variety of goods for every kind of factories and offices including Protection items, Cleaning supplies, sanitations, office supplies and more.
A large variety of items used in R&D and Clean Room including research Equipment, Laboratory Essentials, Analysis Supplies, Clean Environment-Related Equipment and more.
Choose from thousands of standard stamping die components including Punch & Die, Gas Springs, Guide Components, Coil Springs and many more.
Browse our wide variety of mold components including Ejector Pins, Sleeves, Leader Components, Sprue Bushings and many more.
Browse our injection molding components including Heating Items, Couplers, Hoses and more.
A safety relay unit installable on CC-Link networks.
Part Number
Configured Part Number is shown.
QS90SR2SN-CC image
Input Specifications | ||
---|---|---|
Number of Safety Inputs | 1 safety input (2 inputs) | |
Number of Other Inputs | 1 inrush input | |
Safety Input Rated Input Voltage | 24 V DC (ripple ratio: within 5%) (allowable voltage range: 20.4 to 26.4 V DC) | |
Safety Input Rated Input Current | 4.6 mA (300 mA when starting relay) | |
Input Format | Type | N type |
X0 | Positive common | |
X1 | Negative common | |
Input Insulation Method | Relay insulation | |
Input Common Method | No common (All independent points) | |
Output Specifications | ||
Number of Safety Output Points | 1 safety output point (3 outputs) | |
Rated Load Current | Category 4: 3.6 A / point or less (Category 3: 5.0 A / point or less) | |
Minimum Switching Load | 5 V DC 5 mA | |
Maximum Permissible Contact Voltage | 250 V AC, 30 V DC | |
Resistant Load | 250 V AC / 5 A, 30 V DC / 5 A | |
Lifespan of Relay | Mechanical | 5 million times or more |
Electrical | 100,000 times or more | |
Maximum Switching Frequency | 1,200 times / hour at rated control capacity | |
Response Time | Output Operating Time | 50 ms or less (safety input ON > safety output ON) |
Output Shutdown Time | 20 ms or less (safety input OFF > safety output OFF) | |
Output Insulation Method | Relay insulation | |
Output Common Method | No common (All independent points) | |
Common Specifications | ||
Number of Units for Expansion | Up to 3 expansion safety relay units can be connected | |
Dielectric Strength | Safety output between different poles: 2,500 V AC at 1 mA or less for 1 minute Between safety input and safety output: 2,500 V AC at 1 mA or less for 1 minute Between power supply and safety output: 2,500 V AC at 1 mA or less for 1 minute | |
Insulation Resistance | Safety output between different poles: 100 MΩ or more with 500 V DC ohmmeter Between safety input and safety output: 100 MΩ or more with 500 V DC ohmmeter Between power supply and safety output: 100 MΩ or more with 500 V DC ohmmeter | |
Station Type | Remote I/O stations | |
Number of Occupied Stations | 1 station | |
Unit Power Supply | Voltage | 24 V DC (ripple ratio: within 5%) (allowable voltage range: 20.4 to 26.4 V DC) |
Current | 70 mA (without expansion unit), 145 mA (with 3 expansion units) | |
Safety Power Supply | Voltage | 24 V DC (ripple ratio: within 5%) (allowable voltage range: 20.4 to 26.4 V DC) |
Current | 85 mA (without expansion unit), 325 mA (with 3 expansion units) | |
Protection Grade | IP1X | |
External Wiring Connection Method | 2-piece spring clamp terminal block | |
Communication Cable | Dedicated CC-Link cable compatible with Ver. 1.10 Dedicated CC-Link cable (compatible with Ver. 1.00) Dedicated CC-Link high-performance cable (compatible with Ver. 1.00) | |
External Dimensions | Height (H) | 112 mm |
Width (W) | 45 mm | |
Depth (D) | 113.5 mm | |
Weight | 0.37 kg |
Ambient Operating Temperature | 0 to 55°C | ||
---|---|---|---|
Ambient Storage Temperature | -20 to 75°C | ||
Ambient Operating Humidity | 30 to 85% RH, non-condensing | ||
Ambient Storage Humidity | 30 to 85% RH, non-condensing | ||
Vibration Resistance | JIS B 3502, IEC 61131-2 Compliant | Under Intermittent Vibration | Frequency: 5 to 8.4 Hz, Single amplitude: 3.5 mm Frequency: 8.4 to 150 Hz; Constant acceleration: 9.8 m/s2 Number of sweeps: 10 times in each direction of X, Y and Z |
Under Continuous Vibration | Frequency: 5 to 8.4 Hz, Single amplitude: 1.75 mm Frequency: 8.4 to 150 Hz, Constant acceleration: 4.9 m/s2 | ||
Impact Resistant | JIS B 3502, IEC 61131-2 compliant (147 m/s2, for a duration of 11 ms, 3 times in 3 directions of X, Y and Z with a half-sine pulse) | ||
Operating Atmosphere | No corrosive gases | ||
Operating Altitude | 0 to 2,000 m | ||
Installation Location | Inside the control panel with IP54 or higher | ||
Overvoltage Category | III or lower | ||
Pollution Degree | 2 or less | ||
Equipment Class | Class I |
Part Number |
---|
QS90SR2SN-CC |
QS90SR2SP-CC |
Part Number | Standard Unit Price | Minimum order quantity | Volume Discount | Days to Ship | Type of unit | Input Format |
---|---|---|---|---|---|---|
- | 1 Piece(s) | Quote | N type | X0: Positive Common, X1: Negative Common | ||
- | 1 Piece(s) | Quote | P Type | X0: Positive Common, X1: Positive Common |
Loading...
Type | Other | Total Number of Inputs | 1 Point (2 Outputs) | Safety output points | 1 Point (3 Outputs) |
---|
How can we improve?
How can we improve?