A wide variety of standard and configurable components for factory automation engineers in industries such as automotive, semiconductor, packaging, medical and many more.
A good selection of accessories such as screws, bolts, washers and nuts that you may need for your daily engineering usage.
Browse industrial materials ranging from heat insulating plates, sponges, to metal and plastic materials in different sizes to meet your various applications.
A wide variety of wiring parts for connecting and protecting control and PC parts including Connectors, Cables, Electric Wires, Crimping Terminals and more.
A wide variety of controls and PC parts for electrical engineers including Controls, Powers, PC parts and more.
A wide variety of cutting tools for many uses and work materials including End Mills, Drills, Cutters, Reamers, Turning Tools and more.
A wide variety of tools and supplies used in processing including Machine Tools, Measurement Tools, Grinding and Polishing Supplies and more.
A wide variety of goods used in shipment, material handling and warehouse including Tape supplies, Stretch film, Truck, Shelf, Crane and more.
A large variety of goods for every kind of factories and offices including Protection items, Cleaning supplies, sanitations, office supplies and more.
A large variety of items used in R&D and Clean Room including research Equipment, Laboratory Essentials, Analysis Supplies, Clean Environment-Related Equipment and more.
Choose from thousands of standard stamping die components including Punch & Die, Gas Springs, Guide Components, Coil Springs and many more.
Browse our wide variety of mold components including Ejector Pins, Sleeves, Leader Components, Sprue Bushings and many more.
Browse our injection molding components including Heating Items, Couplers, Hoses and more.
MELSEC-F Series Display Module.
[Features]
· The monitor settings make easy operation at a reasonable cost possible.
· Can be connected to a sequencer with 1 cable. (FX-10DM-SET0)
· Can be mounted directly, with no need for wiring. (FX3G-5DM/FX3U-7DM)
[Applications]
· For machine startup, adjustment, and program changing.
Part Number
Configured Part Number is shown.
FX3U-7DM
Can be mounted on a surface and connected to a sequencer with a cable.
When used with a registration monitor, up to 8 frequently used devices can be registered easily.
Comments and messages can be displayed in an easy-to-see manner in the display content.
Function | Data Change Functions | Current Value Change | Changes Current T, C, and D Values |
---|---|---|---|
Setting Value Change | Changes Current T and C Values | ||
Reset Function | Reset Current T, C, and D Values to 0 | ||
Device Monitoring Function | Word Device (16‑Bit) | Displays T and C current values / setting values and D current value. | |
Word Device (32‑Bit) | 32‑bit counter displays C current value / setting value and D current value. | ||
Registration Monitor Function | A Function for registering in advance up to 8 lines of devices and messages to display | ||
Message Display Function | Displays ASCII code saved to the sequencer data register. Display content can be switched from the sequencer. · Up to 16 single-byte characters per line · Displays letters, numbers, Japanese Kana and symbols. | ||
Comment Function | Displays device monitors and registration monitor screen word device names in the comments in the sequencer. · 8 single-byte characters per line for 16‑bit, 4 characters per line for 32‑bit · Displays letters, numbers, Japanese Kana and symbols. | ||
Buzzer Sound | Can be set ON/OFF. | ||
System Language | Japanese/English switchable | ||
Performance Specifications | Dust-Proof, Waterproof | The operation panel screen has a dustproof and water-proof construction equivalent to IP65f (compliance checked in IP65f testing, but this test does not guarantee the use in all environments). | |
Connectable Sequencers | FX1S, FX3S, FX1N, FX3G, FX2N, FX3U, FX1NC, FX3GC, FX2NC, FX3UC FX3S, FX3G, and FX3GC are treated as FX1N devices. FX3U and FX3UC are treated as FX2N devices. |
Can be mounted directly on the FX3G sequencer, with no need for wiring.
Utilizes a maintenance-free green LED backlight.
Comes with an "Operator function" allowing operation with the keys only, and a "Control function" for control via sequences.
Can be used with a function extension board.
FX3G-5DM
Function | Monitor/Test | Input (X), Output (Y), Auxiliary Relay (M), State (S), Timer (T), Counter (C), Data Register (D) [16‑bit/32‑bit], Expansion Register (R) [16‑bit/32‑bit], Expansion File Register (ER) [16‑bit/32‑bit] Monitor/Test Functions *There is no test function for input (X). | |
---|---|---|---|
Error Check | A function that performs an error check and displays the results | ||
LANGUAGE | Sets the Menu Display Language to Japanese or English. | ||
Contrast Adjustment | Adjusts the contrast (-5 to 10). Default value: 0 | ||
Time Setting | Current Time | Displays the current time. | |
Time Change | Sets the current time. | ||
Keyword | Can unlock the set keyword. | ||
Memory Cassette Transfer | Data can be transferred between the internal EEPROM and a memory cassette. | ||
Designated Device Monitor Function | Displays the monitor/test screen of the designated device on the top screen. | ||
Screensaver Function | Displays a screen saver when no keys are used for a specified time. | ||
Display Screen Protection Function | Can protect all functions valid, change (test) function prohibited and top screen (time display). | ||
Operation Button ON/OFF Information | Allows monitoring of the ON/OFF state of operation buttons. | ||
Current Value Hexadecimal Display Settings | Changes current and set values of times, counters, data registers, expansion registers and expansion file registers to hexadecimal display. *A sequence program is needed to display the current values for timer (T), counter (C), data register (file register) (D) [16‑bit/32‑bit], expansion register (R) [16‑bit/32‑bit], and expansion file register (ER) [16‑bit/32‑bit] as hexadecimal values. | ||
Display/Switch Specifications | Display Elements | STN Monochrome Liquid Crystal | |
Backlight | Green LED Backlight | ||
Display Text | Number Of Characters | Four Lines of 16 Single-byte Characters | |
Text | Single-byte Alphanumerics, Katakana | ||
Menu Display Language | Japanese/English | ||
Switches (Operation Button) | 4 (OK, ESC, +, -) | ||
Performance Specifications | Connectable Sequencers | FX3G |
A holder (1.4 m cable included) for attaching FX3U-7DM type display modules to the panel.
Attachment to a panel door, etc., allows monitoring/testing the device and checking the display screen without opening the door, etc.
FX3U-7DM
Function | Monitor/Test | Device | Input (X), Output (Y), Auxiliary Relay (M), State (S), Timer (T), Counter (C), Data Register (D) [16‑bit/32‑bit], Expansion Register (R) [16‑bit/32‑bit], Expansion File Register (ER)[16‑bit/32‑bit] Monitor/Test Functions *There is no test function for input (X). |
---|---|---|---|
User Registration Device | Up to four data registers (D) [16‑bit/32‑bit] can be registered (a program required). | ||
Error Check | A function that performs an error check and displays the results | ||
LANGUAGE (Menu Display Language Setting) | Sets the Menu Display Language to Japanese or English. | ||
Contrast Adjustment | Adjusts the contrast (-5 To 10). Default value: 0 | ||
Time Setting | Setting | Sets the current time. | |
Display | Displays the current time. | ||
Keyword | Can unlock the set keyword. | ||
Device All Clear | A function for initializing Input (X), Output (Y), Auxiliary Relay (M), State (S), Timer (T), Counter (C), Data Register (D) and Expansion Register (R). However, this does not include the file register (D). (Sets bit device to OFF, and word device current value to 0.) | ||
PC Information | A function for checking version information, keyword state, program memory type and state, and battery voltage, etc. | ||
Scan Time Display | Displays scan time (maximum/minimum/current values). | ||
Memory Cassette Transfer | Data can be transferred/collated between internal RAM and a memory cassette. | ||
Operation Button ON/OFF Information | Allows monitoring of the ON/OFF state of operation buttons (a program required). | ||
Current Value Hexadecimal Display Settings | Changes current values / setting values for timers, counters, data registers, expansion registers and expansion file registers to hexadecimal values (a program required). | ||
Display Screen Protection Function | Can protect all functions valid, change (test) function prohibited and top screen (time display) (a program required). | ||
User Message Display | Can issue display commands for the following codes stored in display devices. Single-byte alphanumerics: 20H To 7DH ASCII codes Katakana: A1H To DFH ASCII code Japanese: SHIFT JIS Code (standards 1 and 2) (a program required) | ||
Performance Specifications | Connectable Sequencers | FX3U, FX3UC-32MT-LT(-2) <Caution> FX3UC-32MT-LT(-2) features FX3U-7DM as standard equipment. |
A holder (1.4‑m cable included) for attaching FX3U-7DM type display modules to a panel.
Attachment to a panel door, etc., allows monitoring/testing the device and checking the display screen without opening the door, etc.
X3U-7DM-HLD
Part Number |
---|
FX3U-7DM |
Part Number | Standard Unit Price | Minimum order quantity | Volume Discount | Days to Ship | Monitor screen | Display color (colors) | Ladder editing function | Language switching function | Representative Standard | Applicable Series | Cable Length (m) | Other specifications |
---|---|---|---|---|---|---|---|---|---|---|---|---|
SGD 158.90 | 1 Piece(s) | 91 Day(s) | - | - | NA | Available | - | FX3U / FX3UC-32MT-LT(-2) | 0 | Can be mounted to the FX3U top surface. No wiring is necessary. Japanese language display is available. Japanese language messages (Kanji, Hiragana, Katakana) can be displayed. FX3UC-32MT-LT(-2) is equipped as standard |
Loading...
Mounting type | Other |
---|
Please check the type/dimensions/specifications of the part FX3U-7DM in the MELSEC-F Series Display Module series.
Part Number |
---|
FX3G-5DM |
FX3S-5DM |
FX3U-7DM-HLD |
Part Number | Standard Unit Price | Minimum order quantity | Volume Discount | Days to Ship | Monitor screen | Display color (colors) | Ladder editing function | Language switching function | Representative Standard | Applicable Series | Cable Length (m) | Other specifications |
---|---|---|---|---|---|---|---|---|---|---|---|---|
SGD 44.80 | 1 Piece(s) | 91 Day(s) | [STN] STN | Monochrome (white/black) | NA | Available | - | FX3G | 0 | Utilizes a maintenance-free green color LED backlight that does not require wiring and can be directly mounted to the FX3G sequencer. Equipped with key only operable Operator Functions and sequencer-controlled Control Functions that can be used in together with a function expansion board. | ||
SGD 59.10 | 1 Piece(s) | 91 Day(s) | - | - | - | - | CE | FX3S | - | Equipped with LED backlight. | ||
SGD 79.60 | 1 Piece(s) | 91 Day(s) | - | - | NA | Available | - | FX3UC-32MT-LT(-2) / FX3U | 1.4 | Holder (includes cable length: 1.4 m) for mounting the FX3U-7DM display module to panel surfaces. FX3U (FX3UC-32MT-LT (-3) is equipped as standard) |