GOT1000 CC-Link Communication Unit

GOT1000 CC-Link Communication Unit

CC-Link Communication Unit for GOT1000 Series.
[Features]
・ Intelligent device station module CC-Link Ver.2 compatible
・ Number of occupied stations 1 station/4 stations selectable

PDF

Part Number

Configured Part Number is shown.

GT15-J61BT13

GOT1000 CC-Link Communication Unit Details

Product image of GT15-J61BT13

Product image of GT15-J61BT13

Dimensional Drawing of the Product

 

(Unit: mm)

 

GT15-J61BT13 dimensional drawing

GT15-J61BT13 dimensional drawing

Product Specifications

CategoryCommunication unit
SeriesGOT1000
UnitCC-Link Communication Unit
Product Type NameGT15-J61BT13
Applicable StandardsUL/cUL, CE(EMC), KC
Supported ModelsGT27, GT25 (5.7 type, wide model, enhanced environmental resistance model are excluded), GT16, GT15
CC-Link Station TypeIntelligent Device Station
Number of Occupied StationsPossible to select 1 or 4 stations
Ver. 1 ModeMaximum Link Points Per SystemRemote inputs/outputs (RX, RY): 2,048 points, Remote registers (RWw): 256 points, Remote registers (RWr): 256 points
Link Points Per StationRemote inputs/outputs (RX, RY): 32 points, Remote registers (RWw): 4 points, Remote registers (RWr): 4 points
Number of Link Points Per Number of Occupied Stations"One station occupied" Remote inputs/outputs (RX, RY): 32 points, Remote registers (RWw): 4 points, Remote registers (RWr): 4 points,
"4 stations occupied" Remote inputs/outputs (RX, RY): 128 points, Remote registers (RWw): 16 points, Remote registers (RWr): 16 points
Ver. 2 ModeMaximum Link Points Per SystemRemote inputs/outputs (RX, RY): 8,192 points, Remote registers (RWw): 2,048 points, Remote registers (RWr): 2,048 points
Link Points Per StationExpanded Cyclic Setting: × 1 SettingRemote inputs/outputs (RX, RY): 32 points, Remote registers (RWw): 4 points, Remote registers (RWr): 4 points
Expanded Cyclic Setting: × 2 SettingRemote inputs/outputs (RX, RY): 32 points, Remote registers (RWw): 8 points, Remote registers (RWr): 8 points
Expanded Cyclic Setting: × 4 SettingRemote inputs/outputs (RX, RY): 64 points, Remote registers (RWw): 16 points, Remote registers (RWr): 16 points
Expanded Cyclic Setting: × 8 SettingRemote inputs/outputs (RX, RY): 128 points, Remote registers (RWw): 32 points, Remote registers (RWr): 32 points
Number of Link Points Per Number of Occupied StationsExpanded Cyclic Setting: × 1 Setting"One station occupied" Remote inputs/outputs (RX, RY): 32 points, Remote registers (RWw): 4 points, Remote registers (RWr): 4 points,
"4 stations occupied" Remote inputs/outputs (RX, RY): 128 points, Remote registers (RWw): 16 points, Remote registers (RWr): 16 points
Expanded Cyclic Setting: × 2 Setting"One station occupied" Remote inputs/outputs (RX, RY): 32 points, Remote registers (RWw): 8 points, Remote registers (RWr): 8 points,
"4 stations occupied" Remote inputs/outputs (RX, RY): 224 points, Remote registers (RWw): 32 points, Remote registers (RWr): 32 points
Expanded Cyclic Setting: × 4 Setting"One station occupied" Remote inputs/outputs (RX, RY): 64 points, Remote registers (RWw): 16 points, Remote registers (RWr): 16 points,
"4 stations occupied" Remote inputs/outputs (RX, RY): 448 points, Remote registers (RWw): 64 points, Remote registers (RWr): 64 points
Expanded Cyclic Setting: × 8 Setting"One station occupied" Remote inputs/outputs (RX, RY): 128 points, Remote registers (RWw): 32 points, Remote registers (RWr): 32 points,
"4 stations occupied" Remote inputs/outputs (RX, RY): 896 points, Remote registers (RWw): 128 points, Remote registers (RWr): 128 points
Transmission Speed156 kbps / 625 kbps / 2.5 Mbps / 5 Mbps / 10 Mbps
Maximum Transmission DistanceVaries depending on the transmission speed.
Maximum Number of Connected Devices26 devices Maximum number of connected devices varies depending on the CC-Link system configuration used. For details of maximum number of connected devices, refer to CC-Link user’s manual (detailed version).
Connection CableCC-Link dedicated cable
Internal Current Consumption (5 V DC)0.56 A
Weight0.18 kg
Terminal BlockScrew Tightening TorqueScrew for wiring: 0.5 to 0.6 N·m
Terminal block mounting screw: 0.7 to 0.8 N·m
Recommended DriverrStraight slot screwdriver (blade point thickness: 0.6 mm, width 3.5 mm)
  • *When mounting an expansion unit on the CC-Link Communication Unit, the ambient temperature for general specifications should be 5°C lower than the maximum temperature.
  • *Remote input/output with the maximum link points per system: Input/output signals (RX, RY) occupy 16 points of system area within each device point.
Part Number
GT15-J61BT13
Part NumberStandard Unit PriceMinimum order quantityVolume DiscountDays to Ship

SGD 1,017.50

1 Piece(s) 91 Day(s)

Loading...

  1. 1
 

Basic Information

Type Communication Unit Compatible Model G15 / G16 Communication Speed(bps) 156k/625k/2.5M/5M/10M
Current Consumption(mA) 560 Maximum Number of Connected Devices(Units) 26 Note Performs monitoring as an intelligent device station (number of occupied stations: selectable from 1 or 4). Transmission speeds of 156 kbps/ 625 kbps/ 2.5 Mbps/ 5 Mbps/ 10 Mbps. The maximum transmission distance depends on the transmission speed. Maximum Number of Connecting Dives: 26 - The maximum number of connecting devices differs depending on the CC-Link system configuration. For more information about the maximum number of connecting devices, please refer to the CC-Link user manual (detailed edition).