(!)Due to Microsoft's end of support for Internet Explorer 11 on 15/06/2022, this site does not support the recommended environment.
Instead, please kindly use other browsers like Google Chrome, Microsoft Edge or Mozilla Firefox.
A wide variety of standard and configurable components for factory automation engineers in industries such as automotive, semiconductor, packaging, medical and many more.
A good selection of accessories such as screws, bolts, washers and nuts that you may need for your daily engineering usage.
Browse industrial materials ranging from heat insulating plates, sponges, to metal and plastic materials in different sizes to meet your various applications.
A wide variety of wiring parts for connecting and protecting control and PC parts including Connectors, Cables, Electric Wires, Crimping Terminals and more.
A wide variety of controls and PC parts for electrical engineers including Controls, Powers, PC parts and more.
A wide variety of cutting tools for many uses and work materials including End Mills, Drills, Cutters, Reamers, Turning Tools and more.
A wide variety of tools and supplies used in processing including Machine Tools, Measurement Tools, Grinding and Polishing Supplies and more.
A wide variety of goods used in shipment, material handling and warehouse including Tape supplies, Stretch film, Truck, Shelf, Crane and more.
A large variety of goods for every kind of factories and offices including Protection items, Cleaning supplies, sanitations, office supplies and more.
A large variety of items used in R&D and Clean Room including research Equipment, Laboratory Essentials, Analysis Supplies, Clean Environment-Related Equipment and more.
Choose from thousands of standard stamping die components including Punch & Die, Gas Springs, Guide Components, Coil Springs and many more.
Browse our wide variety of mold components including Ejector Pins, Sleeves, Leader Components, Sprue Bushings and many more.
Browse our injection molding components including Heating Items, Couplers, Hoses and more.
CC-Link Communication Unit for GOT1000 Series.
[Features]
・ Intelligent device station module CC-Link Ver.2 compatible
・ Number of occupied stations 1 station/4 stations selectable
Part Number
Configured Part Number is shown.
GT15-J61BT13
Product image of GT15-J61BT13
(Unit: mm)
GT15-J61BT13 dimensional drawing
Category | Communication unit | ||
---|---|---|---|
Series | GOT1000 | ||
Unit | CC-Link Communication Unit | ||
Product Type Name | GT15-J61BT13 | ||
Applicable Standards | UL/cUL, CE(EMC), KC | ||
Supported Models | GT27, GT25 (5.7 type, wide model, enhanced environmental resistance model are excluded), GT16, GT15 | ||
CC-Link Station Type | Intelligent Device Station | ||
Number of Occupied Stations | Possible to select 1 or 4 stations | ||
Ver. 1 Mode | Maximum Link Points Per System | Remote inputs/outputs (RX, RY): 2,048 points, Remote registers (RWw): 256 points, Remote registers (RWr): 256 points | |
Link Points Per Station | Remote inputs/outputs (RX, RY): 32 points, Remote registers (RWw): 4 points, Remote registers (RWr): 4 points | ||
Number of Link Points Per Number of Occupied Stations | "One station occupied" Remote inputs/outputs (RX, RY): 32 points, Remote registers (RWw): 4 points, Remote registers (RWr): 4 points, "4 stations occupied" Remote inputs/outputs (RX, RY): 128 points, Remote registers (RWw): 16 points, Remote registers (RWr): 16 points | ||
Ver. 2 Mode | Maximum Link Points Per System | Remote inputs/outputs (RX, RY): 8,192 points, Remote registers (RWw): 2,048 points, Remote registers (RWr): 2,048 points | |
Link Points Per Station | Expanded Cyclic Setting: × 1 Setting | Remote inputs/outputs (RX, RY): 32 points, Remote registers (RWw): 4 points, Remote registers (RWr): 4 points | |
Expanded Cyclic Setting: × 2 Setting | Remote inputs/outputs (RX, RY): 32 points, Remote registers (RWw): 8 points, Remote registers (RWr): 8 points | ||
Expanded Cyclic Setting: × 4 Setting | Remote inputs/outputs (RX, RY): 64 points, Remote registers (RWw): 16 points, Remote registers (RWr): 16 points | ||
Expanded Cyclic Setting: × 8 Setting | Remote inputs/outputs (RX, RY): 128 points, Remote registers (RWw): 32 points, Remote registers (RWr): 32 points | ||
Number of Link Points Per Number of Occupied Stations | Expanded Cyclic Setting: × 1 Setting | "One station occupied" Remote inputs/outputs (RX, RY): 32 points, Remote registers (RWw): 4 points, Remote registers (RWr): 4 points, "4 stations occupied" Remote inputs/outputs (RX, RY): 128 points, Remote registers (RWw): 16 points, Remote registers (RWr): 16 points | |
Expanded Cyclic Setting: × 2 Setting | "One station occupied" Remote inputs/outputs (RX, RY): 32 points, Remote registers (RWw): 8 points, Remote registers (RWr): 8 points, "4 stations occupied" Remote inputs/outputs (RX, RY): 224 points, Remote registers (RWw): 32 points, Remote registers (RWr): 32 points | ||
Expanded Cyclic Setting: × 4 Setting | "One station occupied" Remote inputs/outputs (RX, RY): 64 points, Remote registers (RWw): 16 points, Remote registers (RWr): 16 points, "4 stations occupied" Remote inputs/outputs (RX, RY): 448 points, Remote registers (RWw): 64 points, Remote registers (RWr): 64 points | ||
Expanded Cyclic Setting: × 8 Setting | "One station occupied" Remote inputs/outputs (RX, RY): 128 points, Remote registers (RWw): 32 points, Remote registers (RWr): 32 points, "4 stations occupied" Remote inputs/outputs (RX, RY): 896 points, Remote registers (RWw): 128 points, Remote registers (RWr): 128 points | ||
Transmission Speed | 156 kbps / 625 kbps / 2.5 Mbps / 5 Mbps / 10 Mbps | ||
Maximum Transmission Distance | Varies depending on the transmission speed. | ||
Maximum Number of Connected Devices | 26 devices Maximum number of connected devices varies depending on the CC-Link system configuration used. For details of maximum number of connected devices, refer to CC-Link user’s manual (detailed version). | ||
Connection Cable | CC-Link dedicated cable | ||
Internal Current Consumption (5 V DC) | 0.56 A | ||
Weight | 0.18 kg | ||
Terminal Block | Screw Tightening Torque | Screw for wiring: 0.5 to 0.6 N·m Terminal block mounting screw: 0.7 to 0.8 N·m | |
Recommended Driver | rStraight slot screwdriver (blade point thickness: 0.6 mm, width 3.5 mm) |
Part Number |
---|
GT15-J61BT13 |
Part Number | Standard Unit Price | Minimum order quantity | Volume Discount | Days to Ship |
---|---|---|---|---|
SGD 1,017.50 | 1 Piece(s) | 91 Day(s) |
Loading...
Type | Communication Unit | Compatible Model | G15 / G16 | Communication Speed(bps) | 156k/625k/2.5M/5M/10M |
---|---|---|---|---|---|
Current Consumption(mA) | 560 | Maximum Number of Connected Devices(Units) | 26 | Note | Performs monitoring as an intelligent device station (number of occupied stations: selectable from 1 or 4). Transmission speeds of 156 kbps/ 625 kbps/ 2.5 Mbps/ 5 Mbps/ 10 Mbps. The maximum transmission distance depends on the transmission speed. Maximum Number of Connecting Dives: 26 - The maximum number of connecting devices differs depending on the CC-Link system configuration. For more information about the maximum number of connecting devices, please refer to the CC-Link user manual (detailed edition). |
Please check the type/dimensions/specifications of the part GT15-J61BT13 in the GOT1000 CC-Link Communication Unit series.