(!)Due to Microsoft's end of support for Internet Explorer 11 on 15/06/2022, this site does not support the recommended environment.
Instead, please kindly use other browsers like Google Chrome, Microsoft Edge or Mozilla Firefox.

  • Scheduled Maintenance Notice: This site will be unavailable due to scheduled maintenance from 9:00 24/11/2024 to 7:00 (SGT) 25/11/2024. We apologize for the inconvenience.
  • Notice of End of Sales for Economy Series Pneumatic Equipment Category. More information.

GOT1000 External Input/Output Unit

GOT1000 External Input/Output Unit

Mitsubishi GOT1000 External Input/Output Unit.
[Features]
·For the GOT1000 series.
[Applications]
·Used as an external input/output unit.

PDF

Part Number

Configured Part Number is shown.

GT15-DIO

GOT1000 External Input/Output Unit Specifications

Product image of GOT1000 External Input/Output Unit

Product image of GOT1000 External Input/Output Unit

Specifications

 

(Unit: mm)

 

GT15-DIO dimensional drawing

GT15-DIO dimensional drawing

GT15-DIO Specifications

CategoryOptional unit
SeriesGOT1000
UnitExternal input/output unit
Product Type NameGT15-DIO
Applicable StandardsUL/cUL, CE(EMC), KC, ABS, BV, DNV GL, LR, NK, RINA
Supported ModelsGT27, GT25 (5.7 type, wide model, enhanced environmental resistance model, Handy GOT are excluded), GT16, GT15
Common SpecificationsExternal Connection Method50-pin connector
Compatible Wire SizeAWG#28 or less
Operation DisplayN/A
External Power SupplyVoltage24 V DC (+20%/-15%, ripple ratio within 5%)
Current1.85 A
Dielectric Strength350 V AC for 1 minute
Internal Current Consumption0.10 A
Weight0.13 kg
Input Specifications (Source Type)Input MethodDynamic scan method
Number of Inputs16 points / 128 points (16 × 8) (Output 8 points for scan)
Insulation MethodOpto-isolator insulation
Rated Input Voltage24 V DC (+20%/-15%, ripple ratio within 5%)
Rated Input CurrentApprox. 4 mA
Input Derating(External input/output unit [Positive common input / Sink type output] [for GOT2000 Series/GOT1000 Series] Refer to Instruction Manual.)
ON Voltage / ON Current15 V DC or more / 2 mA or more
OFF Voltage / OFF Current4 V DC or less / 1 mA or less
Input ResistanceApprox. 5.6 KΩ
Response TimeON → OFF0.4 ms or less (24 V DC)
OFF → ON0.4 ms or less (24 V DC)
Common Method16 points 1 common (common terminal: 0 V (Pin number 26 to 29))
Dynamic Scan Cycle13.3 ms
Output Specifications (Sink Type)Output MethodDirect output
Number of Outputs16 points + 1 point (RUN output)
Insulation MethodOpto-isolator insulation
Rated Load Voltage24 V DC (+20%/-15%)
Max Load Current0.1 A / 1 point
Maximum Inrush Current0.7 A 10 ms or less
Leakage Current When OFF0.1 mA or less
Maximum Voltage Drop When ON0.2 V DC (Max.) 0.1 A
Protection FunctionAvailable (Overload protection function, overheat protection function)
Response TimeON → OFF1 ms or less (resistant load)
OFF → ON1 ms or less
Common Method16 points 1 common (common terminal: 24 V (Pin number 1 to 4))
Surge SuppressorZener diode

Restrictions

  • External power supply voltage: When the external power supply is cut off, a system alarm is generated.
  • ON voltage / ON current, OFF voltage / OFF current: EN61131-2:2003 (digital input type 1) compatible
  • Response Time: Time consumed in I/O part.
  • Number of Outputs Points: RUN output ON: During normal operation / OFF: WDT error in GOT main body
  • Protection function: A function to protect the internal elements of unit. It does not exist in RUN output. This is not a function to protect external devices. Automatically recovers when it is no longer overloaded or overheated. Overload protection function operates independently for each point with 1 to 3 A / 1 point. Overheat Protection Function operates independently for each point.

GT15-DIOR Specifications

CategoryOptional unit
SeriesGOT1000
UnitExternal input/output unit
Product Type NameGT15-DIOR
Applicable StandardsUL/cUL, CE(EMC), KC, ABS, BV, DNV GL, LR, NK, RINA
Supported ModelsGT27, GT25 (5.7 type, wide model, enhanced environmental resistance model, Handy GOT are excluded), GT16, GT15
Common SpecificationsExternal Connection Method50-pin connector
Compatible Wire SizeAWG#28 or less
Operation DisplayN/A
External Power SupplyVoltage24 V DC (+20%/-15%, ripple ratio within 5%)
Current1.85 A
Dielectric Strength350 V AC for 1 minute
Internal Current Consumption0.10 A
Weight0.13 kg
Input Specifications (Sink Type)Input MethodDynamic scan method
Number of Inputs16 points / 128 points (16 × 8) (Output 8 points for scan)
Insulation MethodOpto-isolator insulation
Rated Input Voltage24 V DC (+20%/-15%, ripple ratio within 5%)
Rated Input CurrentApprox. 4 mA
Input Derating(External input/output unit [Negative common input / Source type output] [for GOT2000 Series/GOT1000 Series] refer to instruction manual.)
ON Voltage / ON Current15 V DC or more / 2 mA or more
OFF Voltage / OFF Current4 V DC or less / 1 mA or less
Input ResistanceApprox. 5.6 KΩ
Response TimeON → OFF0.4 ms or less (24 V DC)
OFF → ON0.4 ms or less (24 V DC)
Common Method16 points 1 common (common terminal: 0 V (Pin number 26 to 29))
Dynamic Scan Cycle13.3 ms
Output Specifications (Source Type)Output MethodDirect output
Number of Outputs16 points + 1 point (RUN output)
Insulation MethodOpto-isolator insulation
Rated Load Voltage24 V DC (+20%/-15%)
Max Load Current0.1 A / 1 point
Maximum Inrush Current0.7 A 10 ms or less
Leakage Current When OFF0.1 mA or less
Maximum Voltage Drop When ON0.2 V DC (Max.) 0.1 A
Protection FunctionAvailable (Overload protection function, overheat protection function)
Response TimeON → OFF1 ms or less (resistant load)
OFF → ON1 ms or less
Common Method16 points 1 common (common terminal: 24 V (Pin number 1 to 4))
Surge SuppressorZener diode

Restrictions

  • External power supply voltage: When the external power supply is cut off, a system alarm is generated.
  • ON voltage / ON current, OFF voltage / OFF current: EN61131-2:2003 (digital input type 1) compatible
  • Response Time: Time consumed in I/O part.
  • Number of Outputs Points: RUN output ON: During normal operation / OFF: WDT error in GOT main body
  • Protection function: A function to protect the internal elements of unit. It does not exist in RUN output. This is not a function to protect external devices. Automatically recovers when it is no longer overloaded or overheated. Overload protection function operates independently for each point with 1 to 3 A / 1 point. Overheat Protection Function operates for each 2 points (with a combination of YD00/YD01 to YD0E/YD0F).
Part Number
GT15-DIO
Part NumberStandard Unit PriceMinimum order quantityVolume DiscountDays to ShipType Input method Output Method

SGD 611.10

1 Piece(s) 91 Day(s) An External Input/Output UnitPositive CommonSink

Loading...

  1. 1
 

Basic Information

Compatible Model GT15 / GT16 Connector 1 50P connector Number Of Inputs(Point) 128
Number of Outputs(Point) 16 Power Supply Voltage(V) DC24 Current Consumption(mA) 100
Overview A maximum of 128 point input and 16 point output

Please check the type/dimensions/specifications of the part GT15-DIO in the GOT1000 External Input/Output Unit series.

Similar Part Numbers

Part Number
GT15-DIOR
Part NumberStandard Unit PriceMinimum order quantityVolume DiscountDays to ShipType Input method Output Method

SGD 611.10

1 Piece(s) 91 Day(s) -Negative CommonSource

Tech Support

Factory Automation, Electronics, Tools, & MRO (Maintenance, Repair and Operations)
Tel:(65) 6733 7211 / FAX:(65) 6733 0211
9:00am - 6:00pm (Monday - Friday)