MELSEC-Q Series Serial Communication Unit (Part Numbers)

MELSEC-Q Series Serial Communication Unit

A serial communication unit for the versatile MELSEC-Q series

PDF

Part Number

Configured Part Number is shown.

QJ71C24N

Serial Communication Unit Features

High-speed, large-capacity communication of up to 960 words (in the case of MC protocol communication) at speeds up to 230.4 kbps is possible.
Data can be read and written from/to the sequencer from external devices (PC, display, etc.) using the MC protocol.
Non-procedural protocol communication is supported to permit data exchange between the sequencer and a given external device (barcode reader, measuring instrument, etc.) in any communication protocol specified by the external device.
Sequencers can be programmed and monitored from a programming tool based on RS-232 serial communication using the QJ71C24N(-R2).
The QJ71C24N(-R2) has a function supporting public network modems and is capable of initializing an applicable modem and connecting with the other device to communicate with any remote device or programming tool via the modem and a public network.
The QJ71C24N(-R2) has a remote password function that prevents illegal access to the Q-series sequencers using the QJ71C24N(-R2)'s modem function.

QJ71C24N Specifications

InterfaceCH. 1RS-232 compliant (D-Sub 9P)
CH. 2RS-422/485-compliant (2-piece terminal block)
Communication MethodCircuitFull-duplex Communication / Half-duplex Communication
MELSEC Communication Protocol CommunicationHalf-duplex communication
Communication Protocol CommunicationFull-duplex Communication / Half-duplex Communication
Nonprocedural Protocol CommunicationFull-duplex Communication / Half-duplex Communication
Bidirectional Protocol CommunicationFull-duplex Communication / Half-duplex Communication
Synchronization MethodAsynchronous method
Transmission Speed50, 300, 600, 1,200, 2,400, 4,800, 9,600, 14,400, 19,200, 28,800, 38,400, 57,600, 115,200, 230,400 bps
· 230,400 bps is available only on CH1 side (not available on CH2 side)
· The total transmission speed of the two interfaces must be within 230,400 bps
· When the send/receive data monitoring function is used, the total transmission speed of the two interfaces must be within 115,200 bps
Data FormatStart Bit1
Data Bit7/8
Parity Bit1 (Vertical parity) / None
Stop Bit1/2
Access CycleMELSEC Communication Protocol CommunicationOne request is processed as part of the END processing of the sequencer CPU of the installed station
* The number of scans / link scans needed in this process varies depending on the specific request
Communication Protocol CommunicationBoth send and receive requests are executed based on a dedicated command
Nonprocedural Protocol CommunicationData is sent every time a send request is made
while data can be received at all times
Bidirectional Protocol CommunicationData is sent every time a send request is made
while data can be received at all times
Error DetectionParity CheckApplicable to all protocols. If applicable, select odd or even number using a parameter
Checksum CodeWhether to use a checksum code for MC protocol or that for bidirectional protocol is selected by a parameter
In the case of a communication protocol, whether or not a checksum code is available is determined by the selected protocol
In the case of a non-procedural protocol, a checksum code is selected by a user-registered frame
Transmission ControlRS-232DTR/DSR ControlAvailable
RS/CS ControlAvailable
CD Signal ControlAvailable
DC1/DC3 (Xon/Xoff) ControlAvailable
DC2/DC4 ControlAvailable
RS-422/485DTR/DSR ControlNot available
RS/CS ControlNot available
CD Signal ControlNot available
DC1/DC3 (Xon/Xoff) ControlAvailable
DC2/DC4 ControlAvailable
Circuit Configuration (Target Equipment Side: CPU Unit Side)RS-232MELSEC Communication Protocol1:1
Communication Protocol1:1
Non-Procedural Protocol1:1
Bidirectional Protocol1:1
RS-422/485MELSEC Communication Protocol1:1, 1:n, m:n (the total of n and m+n cannot be greater than 32)
Communication Protocol1:1, n:1 (n cannot be greater than 32)
Non-Procedural Protocol1:1, 1:n, n:1 (n cannot be greater than 32)
Bidirectional Protocol1:1
Transmitting DistanceRS-232Maximum 15 m
RS-422/485Maximum 1,200 m (total extension distance)
Number of Occupied Inputs/Outputs32 points (I/O assignment: intelligent 32 points)
5 V DC Internal Current Consumption0.31 A
External DimensionsHeight (H)98 mm
Width (W)27.4 mm
Depth (D)90 mm
Weight0.20 kg

QJ71C24N-R2 Specifications

InterfaceCH. 1RS-232 compliant (D-Sub 9P)
CH. 2RS-232 compliant (D-Sub 9P)
Communication MethodCircuitFull-duplex Communication / Half-duplex Communication
MELSEC Communication Protocol CommunicationHalf-duplex communication
Communication Protocol CommunicationFull-duplex Communication / Half-duplex Communication
Nonprocedural Protocol CommunicationFull-duplex Communication / Half-duplex Communication
Bidirectional Protocol CommunicationFull-duplex Communication / Half-duplex Communication
Synchronization MethodAsynchronous method
Transmission Speed50, 300, 600, 1,200, 2,400, 4,800, 9,600, 14,400, 19,200, 28,800, 38,400, 57,600, 115,200, 230,400 bps
· 230,400 bps is available only on CH1 side (not available on CH2 side)
· The total transmission speed of the two interfaces must be within 230,400 bps
· When the send/receive data monitoring function is used, the total transmission speed of the two interfaces must be within 115,200 bps
Data FormatStart Bit1
Data Bit7/8
Parity Bit1 (Vertical parity) / None
Stop Bit1/2
Access CycleMELSEC Communication Protocol CommunicationOne request is processed as part of the END processing of the sequencer CPU of the installed station
* The number of scans / link scans needed in this process varies depending on the specific request
Communication Protocol CommunicationBoth send and receive requests are executed based on a dedicated command
Nonprocedural Protocol CommunicationData is sent every time a send request is made
while data can be received at all times
Bidirectional Protocol CommunicationData is sent every time a send request is made
while data can be received at all times
Error DetectionParity CheckApplicable to all protocols. If applicable, select odd or even number using a parameter
Checksum CodeWhether to use a checksum code for MC protocol or that for bidirectional protocol is selected by a parameter
In the case of a communication protocol, whether or not a checksum code is available is determined by the selected protocol
In the case of a non-procedural protocol, a checksum code is selected by a user-registered frame
Transmission ControlRS-232DTR/DSR ControlAvailable
RS/CS ControlAvailable
CD Signal ControlAvailable
DC1/DC3 (Xon/Xoff) ControlAvailable
DC2/DC4 ControlAvailable
Circuit Configuration (Target Equipment Side: CPU Unit Side)RS-232MELSEC Communication Protocol1:1
Communication Protocol1:1
Non-Procedural Protocol1:1
Bidirectional Protocol1:1
Transmitting DistanceRS-232Maximum 15 m
Number of Occupied Inputs/Outputs32 points (I/O assignment: intelligent 32 points)
5 V DC Internal Current Consumption0.26 A
External DimensionsHeight (H)98 mm
Width (W)27.4 mm
Depth (D)90 mm
Weight0.20 kg

QJ71C24N-R4 Specifications

InterfaceCH. 1RS-422/485 compliant (2-piece thrust-type terminal block)
CH. 2RS-422/485 compliant (2-piece thrust-type terminal block)
Communication MethodCircuitFull-duplex Communication / Half-duplex Communication
MELSEC Communication Protocol CommunicationHalf-duplex communication
Communication Protocol CommunicationFull-duplex Communication / Half-duplex Communication
Nonprocedural Protocol CommunicationFull-duplex Communication / Half-duplex Communication
Bidirectional Protocol CommunicationFull-duplex Communication / Half-duplex Communication
Synchronization MethodAsynchronous method
Transmission Speed50, 300, 600, 1,200, 2,400, 4,800, 9,600, 14,400, 19,200, 28,800, 38,400, 57,600, 115,200, 230,400 bps
· 230,400 bps is available only on CH1 side (not available on CH2 side)
· The total transmission speed of the two interfaces must be within 230,400 bps
· When the send/receive data monitoring function is used, the total transmission speed of the two interfaces must be within 115,200 bps
Data FormatStart Bit1
Data Bit7/8
Parity Bit1 (Vertical parity) / None
Stop Bit1/2
Access CycleMELSEC Communication Protocol CommunicationOne request is processed as part of the END processing of the sequencer CPU of the installed station
* The number of scans / link scans needed in this process varies depending on the specific request
Communication Protocol CommunicationBoth send and receive requests are executed based on a dedicated command
Nonprocedural Protocol CommunicationData is sent every time a send request is made
while data can be received at all times
Bidirectional Protocol CommunicationData is sent every time a send request is made
while data can be received at all times
Error DetectionParity CheckApplicable to all protocols. If applicable, select odd or even number using a parameter
Checksum CodeWhether to use a checksum code for MC protocol or that for bidirectional protocol is selected by a parameter
In the case of a communication protocol, whether or not a checksum code is available is determined by the selected protocol
In the case of a non-procedural protocol, a checksum code is selected by a user-registered frame
Transmission ControlRS-422/485DTR/DSR ControlNot available
RS/CS ControlNot available
CD Signal ControlNot available
DC1/DC3 (Xon/Xoff) ControlAvailable
DC2/DC4 ControlAvailable
Circuit Configuration (Target Equipment Side: CPU Unit Side)RS-422/485MELSEC Communication Protocol1:1, 1:n, m:n (the total of n and m+n cannot be greater than 32)
Communication Protocol1:1, n:1 (n cannot be greater than 32)
Non-Procedural Protocol1:1, 1:n, n:1 (n cannot be greater than 32)
Bidirectional Protocol1:1
Transmitting DistanceRS-422/485Maximum 1,200 m (total extension distance)
Number of Occupied Inputs/Outputs32 points (I/O assignment: intelligent 32 points)
5 V DC Internal Current Consumption0.39 A
External DimensionsHeight (H)98 mm
Width (W)27.4 mm
Depth (D)90 mm
Weight0.20 kg
Part Number
QJ71C24N
Part NumberStandard Unit PriceMinimum order quantityVolume DiscountDays to ShipCommunication Interface (Transmission Standard) CH1 interface CH2 interface

SGD 711.80

1 Piece(s) 20 Day(s) RS-232RS-232RS-422/485

Loading...

  1. 1
 

Please check the type/dimensions/specifications of the part QJ71C24N in the MELSEC-Q Series Serial Communication Unit series.

Similar Part Numbers

Part Number
QJ71C24N-R2
QJ71C24N-R4
Part NumberStandard Unit PriceMinimum order quantityVolume DiscountDays to ShipCommunication Interface (Transmission Standard) CH1 interface CH2 interface

SGD 711.80

1 Piece(s) 20 Day(s) RS-232RS-232RS-232

SGD 711.80

1 Piece(s) 20 Day(s) RS-422/485RS-422/485RS-422/485

Tech Support

Factory Automation, Electronics, Tools, & MRO (Maintenance, Repair and Operations)
Tel:(65) 6733 7211 / FAX:(65) 6733 0211
9:00am - 6:00pm (Monday - Friday)