(!)Due to Microsoft's end of support for Internet Explorer 11 on 15/06/2022, this site does not support the recommended environment.
Instead, please kindly use other browsers like Google Chrome, Microsoft Edge or Mozilla Firefox.

  • Scheduled Maintenance Notice: This site will be unavailable due to scheduled maintenance from 9:00 24/11/2024 to 7:00 (SGT) 25/11/2024. We apologize for the inconvenience.
  • Notice of End of Sales for Economy Series Pneumatic Equipment Category. More information.

MELSEC-F Series Data Link/Communication (Ethernet)

MELSEC-F Series Data Link/Communication (Ethernet) Specifications

FX3U-ENET-ADP

FX3U-ENET-ADP Image

FX3U-ENET-ADP Image

  • By connecting a special adapter for Ethernet communication to the FX3 series basic unit, sequencers used in various devices can be easily connected to Ethernet.
  • Connecting to a network makes it feasible to monitor the status of or change the program of the sequencer from a distance, which improves maintainability.
  • Basic unit can be selected from the rich lineup of the FX3 series.

FX3U-ENET-ADP Performance Specifications

Transmission SpecificationsData Transmission Speed100 Mbps or 10 Mbps
Communication ModeFull-duplex / half-duplex
Transmission MethodBaseband
Maximum Segment Length100 m
Maximum Number of Nodes/Connections10BASE-T: Up to 4 cascade connection levels
100BASE-TX: Up to 2 cascade connection levels
The above is the number of connectable levels when using a repeater hub.
For the number of connectable levels when using a switching hub, check with the manufacturer of the switching hub to be used.
Applicable ConnectorRJ45
Function· MELSOFT connection
· Communication using MC protocol
· Direct connection with MELSOFT (easy connection)
· Connected CPU search function
· Time setting function
*Time setting function (SNTP client) can be executed only after the trigger condition is met
· Diagnostic function from MELSOFT
· Data monitoring function
Number of ConnectionsMELSOFT connection + MC protocol + data monitoring ≤ 4 connections
Number of Connectable Unit to Base UnitOne
Ethernet adapter occupies one communication channel (CH), as n communication function expansion board or other special communication adapters do.
Applicable SequencersFX3S, FX3G (V2.00 or later), FX3U (V3.10 or later), FX3GC (V2.00 or later), FX3UC (V3.10 or later):
FX3S-CNV-ADP is required to connect to the FX3S.
FX3G-CNV-ADP is required to connect to the FX3G.
A function expansion board is required to connect to an FX3U or FX3UC-32MT-LT (-2).
Weight0.1 kg
Power Supply Specifications
Power Supply30 mA / 5 V DC (Energized internally from the 5 V DC power supply of the base unit)
Allowable Momentary Power Outage DurationSame as the connected sequencer

General Specifications

Ambient Temperature0 to 55°C: When operating, -25 to 75°C: When stored
Relative Humidity5 to 95% RH (non-condensing): When operating
Vibration ResistanceWhen Mounting to DIN RailFrequency: 10 to 57 HzSingle amplitude: 0.035 mm, 10 times in each direction of X, Y and Z (total of 80 minutes each)
Frequency: 57 to 150 HzAcceleration: 4.9 m/s2 10 times in each direction of X, Y and Z (total of 80 minutes each)
When Mounting DirectlyFrequency: 10 to 57 HzSingle amplitude: 0.075 mm 10 times in each direction of X, Y and Z (total of 80 minutes each)
Frequency: 57 to 150 HzAcceleration: 9.8 m/s2 10 times in each direction of X, Y and Z (total of 80 minutes each)
Impact Resistant147 m/s2, for a duration of 11 ms, 3 times in each direction of X, Y and Z with a half-sine pulse
Noise ResistanceAchieved through a noise simulator with a noise voltage of 1,000 Vp-p, noise width of 1 μs, the rise time of 1 ns and frequency of 30 to 100 Hz
Withstand VoltageBetween all terminals batch and earth terminal: 500 V AC for 1 minute
Insulation ResistanceBetween all terminals batch and earth terminal: 5 MΩ or more with 500 V DC ohmmeter
Operating AtmosphereThere shall be no corrosion gas or flammable gas and not much conductive dust
Altitude of Use2,000 m or less
Cannot be used in environments pressurized above atmospheric pressure. This may cause failure.
Part Number
FX3U-ENET-ADP
FX3U-ENET-L
Part NumberStandard Unit PriceMinimum order quantityVolume DiscountDays to ShipConnection Terminal Representative Standard Applicable sequencer Type of unit Communication Speed
(kbps)
Transmission Speed

SGD 216.40

1 Piece(s) 91 Day(s) ConnectorCE / UL / CUL-Ethernet interface block100M/10 Mbps-

SGD 601.60

1 Piece(s) 20 Day(s) -CE / ULFX3U / FX3UCEthernet Connection Interface-10Mbps / 100Mbps

Loading...

  1. 1
 

Basic Information

Communication Interface (Transmission Standard) Ethernet

Tech Support

Factory Automation, Electronics, Tools, & MRO (Maintenance, Repair and Operations)
Tel:(65) 6733 7211 / FAX:(65) 6733 0211
9:00am - 6:00pm (Monday - Friday)