MELSEC-F Series High Speed Counter (Part Numbers)

MELSEC-F Series High Speed Counter

A high speed counter for the micro sequencer MELSEC-F series

PDF

MELSEC-F Series High-Speed Counter Specifications

FX3U-2HC

FX3U-2HC image

FX3U-2HC image

  • Each unit has two channels of high-speed input terminals and up to 200 kHz high-speed counting is possible. 2-phase counter can count multiplication by 1, by 2, by 4.
  • Open collector (5, 12 or 24 V DC) or differential line driver (equivalent to AM26C31) output type encoder or sensor can be connected to the input. 16 or 32-bit counter mode can be selected, and multiplication can be specified to the 2-phase counter.
  • The input/output signal connections are made through connectors. Connectors "FX-I/O-CON2-S and FX-I/O-CON2-SA" can be used. (Wiring cable must be provided by customer.)

FX3U-2HC Performance Specifications

Number of Input Channels2 ch
Input FormatOpen collector, differential line driver
(differential line driver output type encoder is connected to the 5 V terminal)
Input VoltageSelected from 5, 12 or 24 V DC depending on the connection terminal
Maximum Response Frequency1-Phase 1 Input200 kHz or less
1-Phase 2 Inputs200 kHz or less
2-Phase Input200 kHz or less (multiplied by 1), 100 kHz or less (multiplied by 2), 50 kHz or less (multiplied by 4)
Count RangeAt 32-bit specification: -2,147,483,648 to +2,147,483,647
At 16-bit specification: 0 to 65,535 (upper limit can be specified with BFM #3, #2, #43, #42)
Count ModeAutomatic up/down
(The counting direction of the 1-phase 1 input counter is determined by the following command)
[H/W up/down]
Counts up/down by OFF/ON of the A-phase input terminal.
[S/W up/down]
Counts up/down by the current value (K0/K1) of BFM #1, #41.
Matching Output (Comparison)When the current value of the counter and the comparison setting match, the comparison output is set (ON) within 30 μs, and is cleared (OFF) within 100 μs by the reset command.
Output FormatOpen collector output, 2 points, 5 to 24 V DC at 0.5 A each
Display (LED)øA, øB, DIS, PRE, YH1, YH2, POWER, UP, DOWN
Number of Occupied Inputs/Outputs8 points (either input or output can be considered)
Applicable SequencersFX5U, FX5UC, FX3U (V2.20 or later), FX3UC (V2.20 or later)
"Connection to FX5U or FX5U CPU unit"
Connection to FX5U or FX5UC requires FX5-CNV-BUS or FX5-CNV-BUSC. Select either one according to the system configuration.
"Connection to connector type sequencer"
Connection to FX3UC requires either FX2NC-CNV-IF or FX3UC-1PS-5V.
Weight0.2 kg
Power Supply Specifications
Power Supply5 V DC, 245 mA (internal power supply from sequencer)

FX3U-2HC General Specifications

Ambient Temperature0 to 55°C: When operating, -25 to 75°C: When stored
Relative Humidity5 to 95% RH (non-condensing): When operating
Vibration ResistanceWhen Mounting to DIN RailFrequency: 10 to 57 HzSingle amplitude: 0.035 mm, 10 times in each direction of X, Y and Z (total of 80 minutes each)
Frequency: 57 to 150 HzAcceleration: 4.9 m/s2 10 times in each direction of X, Y and Z (total of 80 minutes each)
When Mounting DirectlyFrequency: 10 to 57 HzSingle amplitude: 0.075 mm 10 times in each direction of X, Y and Z (total of 80 minutes each)
Frequency: 57 to 150 HzAcceleration: 9.8 m/s2 10 times in each direction of X, Y and Z (total of 80 minutes each)
Impact Resistant147 m/s2, for a duration of 11 ms, 3 times in each direction of X, Y and Z with a half-sine pulse
Noise ResistanceAchieved through a noise simulator with a noise voltage of 1,000 Vp-p, noise width of 1 μs, the rise time of 1 ns, and frequency of 30 to 100 Hz
Withstand VoltageBetween all terminals batch and earth terminal: 500 V AC for 1 minute
Insulation ResistanceBetween all terminals batch and earth terminal: 5 MΩ or more with 500 V DC ohmmeter
GroundingClass D grounding (ground resistance: 100 Ω or less) "Shared grounding with a high-power system is not allowed"
Use dedicated or shared ground.
Operating AtmosphereThere shall be no corrosion gas or flammable gas and not much conductive dust
Altitude of Use2,000 m or less
Cannot be used in environments pressurized above atmospheric pressure. This may cause failure.
Part Number
FX3U-2HC
FX3U-4HSX-ADP
Part NumberStandard Unit PriceMinimum order quantityVolume DiscountDays to ShipNumber of Channels
(ch)
Count Input Format Maximum Response Frequency (1 Phase, 1 Input) Maximum Response Frequency (1 Phase, 2 Input) Maximum Response Frequency (2 Phase Input)

SGD 601.60

1 Piece(s) 20 Day(s) 2Open Collector Differential Line Driver200 kHz or Less200 kHz or Less200 kHz or Less (1 Multiplication), 100 kHz or Less (2 Multiplication), 50 kHz or Less (4 Multiplication)