MELSEC-F Input/Output Expansion Block (Part Numbers)

MELSEC-F Input/Output Expansion Block

An input/output expansion block that can receive power supply from a basic power supply unit.
[Features]
· Can expand input by 16 points.
· Can be connected to the back of a basic unit or expansion unit.
[Applications]
· Convenient for expanding input/output, receiving power supply from a basic unit or expansion unit.

PDF

Variation

MELSEC-F input/output expansion block: related images

FX2N-16EX

MELSEC-F input/output expansion block: related images

FX2N-16EX-C

MELSEC-F input/output expansion block: related images

FX2N-16EYR

MELSEC-F input/output expansion block: related images

FX2N-16EYT

MELSEC-F input/output expansion block: related images

FX2N-16EYT-C

MELSEC-F input/output expansion block: related images

FX2N-8EX

MELSEC-F input/output expansion block: related images

FX2N-8EYR

MELSEC-F input/output expansion block: related images

FX2NC-16EX-T

General Specifications

Common

Ambient Temperature0 To 55°C - When operating -25 To 75°C - When saving
Relative Humidity5 To 95% RH (No Condensation) - When Operating
Vibration-resistantWhen Mounting To DIN RailFrequency: 10 To 57 HzSingle Amplitude: 0.035 mm 10 Times In Each Direction X, Y, Z (Total 80 Minutes Each)
Assessment Standards Are Based On IEC61131-2
Frequency: 57 To 150 HzAcceleration: 4.9 m/s2 10 Times In Each Direction X, Y, Z (Total 80 Minutes Each)
Assessment Standards Are Based On IEC61131-2
When Mounting DirectlyFrequency: 10 To 57 HzSingle Amplitude: 0.075 mm 10 Times In Each Direction X, Y, Z (Total 80 Minutes Each)
Assessment Standards Are Based On IEC61131-2
Frequency: 57 To 150 HzAcceleration: 9.8 m/s2 10 Times In Each Direction X, Y, Z (Total 80 Minutes Each)
Assessment Standards Are Based On IEC61131-2
Shock-Resistant147 m/s2, For A Half-sine Pulse Three Times In Directions X, Y, And Z For A Duration Of 11 ms. The Assessment Standards Are Based On IEC611131-2
Noise ResistantAchieved Through A Noise Simulator With A Noise Voltage Of 1,000 Vp-p, Noise Width Of 1 μs, Rise Time Of 1 ns, And Frequency Of 30 To 100 Hz
Voltage ResistanceBetween The Expansion Input Block Input Terminal And Earth Terminal: 1 Minute At 500 V AC
Insulation ResistanceBetween The Expansion Input Block Input Terminal And Earth Terminal: 5 MΩ Or More At 500 V DC On An Insulation Resistance Meter
Circumstances Of UseWhen There Is Not A Large Amount Of Conductive Dust, And No Corrosion Or Flammable Gas
Frequency Of UseCannot Be Used In Pressurized Environments Below 2,000 m. Doing So May Cause Failures.

FX2N-16EX

Voltage ResistanceBetween The Expansion Input Block Input Terminal And Earth Terminal: 1 Minute At 500 V AC
Insulation ResistanceBetween The Expansion Input Block Input Terminal And Earth Terminal: 5 MΩ Or More At 500 V DC On An Insulation Resistance Meter

FX2N-16EX-C

Voltage ResistanceBetween The Expansion Input Block Input Terminal And Earth Terminal: 1 Minute At 500 V AC
Insulation ResistanceBetween The Expansion Input Block Input Terminal And Earth Terminal: 5 MΩ Or More At 500 V DC On An Insulation Resistance Meter

FX2N-16EYR

Voltage ResistanceBetween The Expansion Output Block Output Terminal And Earth Terminal: 1 Minute At 1,500 V AC
Insulation ResistanceBetween The Expansion Output Block Output Terminal (Relay) And Earth Terminal: 5 MΩOr More At 500 V DC On An Insulation Resistance Meter

FX2N-16EYT

Voltage ResistanceBetween The Expansion Output Block Output Terminal (Transistor) And Earth Terminal: 1 Minute At 500 V AC
Insulation ResistanceBetween The Expansion Output Block Output Terminal (Transistor) And Earth Terminal: 5 MΩ Or More At 500 V DC On An Insulation Resistance Meter

FX2N-16EYT-C

Voltage ResistanceBetween The Expansion Output Block Output Terminal (Transistor) And Earth Terminal: 1 Minute At 500 V AC
Insulation ResistanceBetween The Expansion Output Block Output Terminal (Transistor) And Earth Terminal: 5 MΩ Or More At 500 V DC On An Insulation Resistance Meter

FX2N-8EX

Voltage ResistanceBetween The Expansion Input Block Input Terminal And Earth Terminal: 1 Minute At 500 V AC
Insulation ResistanceBetween The Expansion Input Block Input Terminal And Earth Terminal: 5 MΩ Or More At 500 V DC On An Insulation Resistance Meter

FX2N-8EYR

Voltage ResistanceBetween The Expansion Output Block Output Terminal And Earth Terminal: 1 Minute At 1,500 V AC
Insulation ResistanceBetween The Expansion Output Block Output Terminal (Relay) And Earth Terminal: 5 MΩOr More At 500 V DC On An Insulation Resistance Meter

FX2NC-16EX-T

Ambient Temperature0 To 55°C - When Operating -20 To 70°C - When Saving
Relative Humidity35 To 85% RH (No Condensation) - When Operating
Vibration-resistantWhen Mounting To DIN RailFrequency: 10 To 57 HzSingle Amplitude: 0.035 mm 10 Times In Each Direction X, Y, Z (Total 80 Minutes Each)
Assessment Standards Are Based On IEC61131-2
Frequency: 57 To 150 HzAcceleration: 4.9 m/s2 10 Times In Each Direction X, Y, Z (Total 80 Minutes Each)
Assessment Standards Are Based On IEC61131-2
Shock-Resistant147 m/s2, For A Half-sine Pulse Three Times In Directions X, Y, And Z For A Duration Of 11 ms.
The Assessment Standards Are Based On IEC611131-2
Noise ResistantAchieved Through A Noise Simulator With A Noise Voltage Of 1,000 Vp-p, Noise Width Of 1 μs, Rise Time Of 1 ns, And Frequency Of 30 To 100 Hz
Voltage ResistanceBetween The Expansion Input Block Input Terminal And Earth Terminal: 1 Minute At 500 V AC
Insulation ResistanceBetween The Expansion Input Block Input Terminal And Earth Terminal: 5 MΩ Or More At 500 V DC On An Insulation Resistance Meter
Part Number
FX5-8EYT/ESS
FX5-16ET/ESS-H
FX5-16EYT/ESS
FX5-32ET/DSS
FX5-C16EYT/DSS
FX5-C32ET/DSS
FX5-C32EYT/DSS
Part NumberStandard Unit PriceMinimum order quantityVolume DiscountDays to ShipNumber Of Inputs Rated Input Voltage
(V)
Number of Outputs Output Format Representative Standard Features Applicable sequencer Number Of Inputs
(Point)
Number of Outputs
(Point)
Terminal shape Type of unit Number of input channels
(ch)
Number of output channels
(ch)
Voltage input range
(V)
Current input range
(mA)
Voltage output range Current output range Type of unit Resistance Load
(A/1 Point)

SGD 138.80

1 Piece(s) 91 Day(s) -NA-Transistor / source outputCE / UL / CUL-FX5U / FX5UCNA8Terminal blockOutput--------

SGD 770.50

1 Piece(s) 91 Day(s) 8DC24V8Transistor / source outputCE / UL / CUL-FX5U / FX5UC88Terminal block-------Input/output-

SGD 194.30

1 Piece(s) 91 Day(s) -NA-Transistor / source outputCE / UL / CUL-FX5U / FX5UCNA16Terminal blockOutput--------

SGD 345.30

1 Piece(s) 91 Day(s) 16DC24V16Transistor / source outputCE / UL / CULBuilt-in DC power supplyFX5U / FX5UC1616Terminal block-------Input/output-

SGD 324.60

1 Piece(s) Quote NANA16Transistor / source outputCE / UL / CUL-FX5U / FX5UCNA16Connector-------Output-

SGD 473.80

1 Piece(s) 91 Day(s) -DC24V-Transistor / source outputCE / UL / CUL-FX5U / FX5UC1616Connector-------Input/output-

SGD 437.30

1 Piece(s) 91 Day(s) -NA-Transistor / source outputCE / UL / CUL-FX5U / FX5UCNA32ConnectorOutput--------