A wide variety of standard and configurable components for factory automation engineers in industries such as automotive, semiconductor, packaging, medical and many more.
A good selection of accessories such as screws, bolts, washers and nuts that you may need for your daily engineering usage.
Browse industrial materials ranging from heat insulating plates, sponges, to metal and plastic materials in different sizes to meet your various applications.
A wide variety of wiring parts for connecting and protecting control and PC parts including Connectors, Cables, Electric Wires, Crimping Terminals and more.
A wide variety of controls and PC parts for electrical engineers including Controls, Powers, PC parts and more.
A wide variety of cutting tools for many uses and work materials including End Mills, Drills, Cutters, Reamers, Turning Tools and more.
A wide variety of tools and supplies used in processing including Machine Tools, Measurement Tools, Grinding and Polishing Supplies and more.
A wide variety of goods used in shipment, material handling and warehouse including Tape supplies, Stretch film, Truck, Shelf, Crane and more.
A large variety of goods for every kind of factories and offices including Protection items, Cleaning supplies, sanitations, office supplies and more.
A large variety of items used in R&D and Clean Room including research Equipment, Laboratory Essentials, Analysis Supplies, Clean Environment-Related Equipment and more.
Choose from thousands of standard stamping die components including Punch & Die, Gas Springs, Guide Components, Coil Springs and many more.
Browse our wide variety of mold components including Ejector Pins, Sleeves, Leader Components, Sprue Bushings and many more.
Browse our injection molding components including Heating Items, Couplers, Hoses and more.
An input/output expansion block that can receive power supply from a basic power supply unit.
[Features]
· Can expand input by 16 points.
· Can be connected to the back of a basic unit or expansion unit.
[Applications]
· Convenient for expanding input/output, receiving power supply from a basic unit or expansion unit.
Part Number
Configured Part Number is shown.
FX2N-16EX
FX2N-16EX-C
FX2N-16EYR
FX2N-16EYT
FX2N-16EYT-C
FX2N-8EX
FX2N-8EYR
FX2NC-16EX-T
Ambient Temperature | 0 To 55°C - When operating -25 To 75°C - When saving | ||
---|---|---|---|
Relative Humidity | 5 To 95% RH (No Condensation) - When Operating | ||
Vibration-resistant | When Mounting To DIN Rail | Frequency: 10 To 57 Hz | Single Amplitude: 0.035 mm 10 Times In Each Direction X, Y, Z (Total 80 Minutes Each) Assessment Standards Are Based On IEC61131-2 |
Frequency: 57 To 150 Hz | Acceleration: 4.9 m/s2 10 Times In Each Direction X, Y, Z (Total 80 Minutes Each) Assessment Standards Are Based On IEC61131-2 | ||
When Mounting Directly | Frequency: 10 To 57 Hz | Single Amplitude: 0.075 mm 10 Times In Each Direction X, Y, Z (Total 80 Minutes Each) Assessment Standards Are Based On IEC61131-2 | |
Frequency: 57 To 150 Hz | Acceleration: 9.8 m/s2 10 Times In Each Direction X, Y, Z (Total 80 Minutes Each) Assessment Standards Are Based On IEC61131-2 | ||
Shock-Resistant | 147 m/s2, For A Half-sine Pulse Three Times In Directions X, Y, And Z For A Duration Of 11 ms. The Assessment Standards Are Based On IEC611131-2 | ||
Noise Resistant | Achieved Through A Noise Simulator With A Noise Voltage Of 1,000 Vp-p, Noise Width Of 1 μs, Rise Time Of 1 ns, And Frequency Of 30 To 100 Hz | ||
Voltage Resistance | Between The Expansion Input Block Input Terminal And Earth Terminal: 1 Minute At 500 V AC | ||
Insulation Resistance | Between The Expansion Input Block Input Terminal And Earth Terminal: 5 MΩ Or More At 500 V DC On An Insulation Resistance Meter | ||
Circumstances Of Use | When There Is Not A Large Amount Of Conductive Dust, And No Corrosion Or Flammable Gas | ||
Frequency Of Use | Cannot Be Used In Pressurized Environments Below 2,000 m. Doing So May Cause Failures. |
Voltage Resistance | Between The Expansion Input Block Input Terminal And Earth Terminal: 1 Minute At 500 V AC |
---|---|
Insulation Resistance | Between The Expansion Input Block Input Terminal And Earth Terminal: 5 MΩ Or More At 500 V DC On An Insulation Resistance Meter |
Voltage Resistance | Between The Expansion Input Block Input Terminal And Earth Terminal: 1 Minute At 500 V AC |
---|---|
Insulation Resistance | Between The Expansion Input Block Input Terminal And Earth Terminal: 5 MΩ Or More At 500 V DC On An Insulation Resistance Meter |
Voltage Resistance | Between The Expansion Output Block Output Terminal And Earth Terminal: 1 Minute At 1,500 V AC |
---|---|
Insulation Resistance | Between The Expansion Output Block Output Terminal (Relay) And Earth Terminal: 5 MΩOr More At 500 V DC On An Insulation Resistance Meter |
Voltage Resistance | Between The Expansion Output Block Output Terminal (Transistor) And Earth Terminal: 1 Minute At 500 V AC |
---|---|
Insulation Resistance | Between The Expansion Output Block Output Terminal (Transistor) And Earth Terminal: 5 MΩ Or More At 500 V DC On An Insulation Resistance Meter |
Voltage Resistance | Between The Expansion Output Block Output Terminal (Transistor) And Earth Terminal: 1 Minute At 500 V AC |
---|---|
Insulation Resistance | Between The Expansion Output Block Output Terminal (Transistor) And Earth Terminal: 5 MΩ Or More At 500 V DC On An Insulation Resistance Meter |
Voltage Resistance | Between The Expansion Input Block Input Terminal And Earth Terminal: 1 Minute At 500 V AC |
---|---|
Insulation Resistance | Between The Expansion Input Block Input Terminal And Earth Terminal: 5 MΩ Or More At 500 V DC On An Insulation Resistance Meter |
Voltage Resistance | Between The Expansion Output Block Output Terminal And Earth Terminal: 1 Minute At 1,500 V AC |
---|---|
Insulation Resistance | Between The Expansion Output Block Output Terminal (Relay) And Earth Terminal: 5 MΩOr More At 500 V DC On An Insulation Resistance Meter |
Ambient Temperature | 0 To 55°C - When Operating -20 To 70°C - When Saving | ||
---|---|---|---|
Relative Humidity | 35 To 85% RH (No Condensation) - When Operating | ||
Vibration-resistant | When Mounting To DIN Rail | Frequency: 10 To 57 Hz | Single Amplitude: 0.035 mm 10 Times In Each Direction X, Y, Z (Total 80 Minutes Each) Assessment Standards Are Based On IEC61131-2 |
Frequency: 57 To 150 Hz | Acceleration: 4.9 m/s2 10 Times In Each Direction X, Y, Z (Total 80 Minutes Each) Assessment Standards Are Based On IEC61131-2 | ||
Shock-Resistant | 147 m/s2, For A Half-sine Pulse Three Times In Directions X, Y, And Z For A Duration Of 11 ms. The Assessment Standards Are Based On IEC611131-2 | ||
Noise Resistant | Achieved Through A Noise Simulator With A Noise Voltage Of 1,000 Vp-p, Noise Width Of 1 μs, Rise Time Of 1 ns, And Frequency Of 30 To 100 Hz | ||
Voltage Resistance | Between The Expansion Input Block Input Terminal And Earth Terminal: 1 Minute At 500 V AC | ||
Insulation Resistance | Between The Expansion Input Block Input Terminal And Earth Terminal: 5 MΩ Or More At 500 V DC On An Insulation Resistance Meter |
Part Number |
---|
FX2NC-16EX-T |
FX2NC-32EX |
FX5-8EX/ES |
FX5-C16EX/D |
FX5-C16EX/DS |
FX5-C32EX/DS |
Part Number | Standard Unit Price | Minimum order quantity | Volume Discount | Days to Ship | Number Of Inputs | Rated Input Voltage (V) | Number of Outputs | Output Format | Representative Standard | Features | Applicable sequencer | Number Of Inputs (Point) | Number of Outputs (Point) | Terminal shape | Type of unit | Number of input channels (ch) | Number of output channels (ch) | Voltage input range (V) | Current input range (mA) | Voltage output range | Current output range | Type of unit | Resistance Load (A/1 Point) |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
SGD 271.70 | 1 Piece(s) | 91 Day(s) | 16 | DC24V | NA | - | CE / UL / CUL | - | FX3GC / FX3UC | 16 | NA | - | - | - | - | - | - | - | - | Input | - | ||
SGD 505.10 | 1 Piece(s) | Quote | 32 | DC24V | NA | - | CE / UL / CUL | - | FX3GC / FX3UC | 32 | NA | - | - | - | - | - | - | - | - | Input | - | ||
SGD 111.10 | 1 Piece(s) | 20 Day(s) | - | DC24V | NA | - | CE / UL / CUL | - | FX5U / FX5UC | 8 | NA | Terminal block | - | - | - | - | - | - | - | Input | - | ||
SGD 267.20 | 1 Piece(s) | 91 Day(s) | 16 | DC24V | NA | - | CE / UL / CUL | - | FX5U / FX5UC | 16 | NA | Connector | - | - | - | - | - | - | - | Input | - | ||
SGD 267.20 | 1 Piece(s) | 91 Day(s) | 16 | DC24V | NA | - | CE / UL / CUL | - | FX5U / FX5UC | 16 | NA | Connector | - | - | - | - | - | - | - | Input | - | ||
SGD 437.30 | 1 Piece(s) | 91 Day(s) | - | DC24V | NA | - | CE / UL / CUL | - | FX5U / FX5UC | 32 | NA | Connector | - | - | - | - | - | - | - | Input | - |