(!)Due to Microsoft's end of support for Internet Explorer 11 on 15/06/2022, this site does not support the recommended environment.
Instead, please kindly use other browsers like Google Chrome, Microsoft Edge or Mozilla Firefox.
A wide variety of standard and configurable components for factory automation engineers in industries such as automotive, semiconductor, packaging, medical and many more.
A good selection of accessories such as screws, bolts, washers and nuts that you may need for your daily engineering usage.
Browse industrial materials ranging from heat insulating plates, sponges, to metal and plastic materials in different sizes to meet your various applications.
A wide variety of wiring parts for connecting and protecting control and PC parts including Connectors, Cables, Electric Wires, Crimping Terminals and more.
A wide variety of controls and PC parts for electrical engineers including Controls, Powers, PC parts and more.
A wide variety of cutting tools for many uses and work materials including End Mills, Drills, Cutters, Reamers, Turning Tools and more.
A wide variety of tools and supplies used in processing including Machine Tools, Measurement Tools, Grinding and Polishing Supplies and more.
A wide variety of goods used in shipment, material handling and warehouse including Tape supplies, Stretch film, Truck, Shelf, Crane and more.
A large variety of goods for every kind of factories and offices including Protection items, Cleaning supplies, sanitations, office supplies and more.
A large variety of items used in R&D and Clean Room including research Equipment, Laboratory Essentials, Analysis Supplies, Clean Environment-Related Equipment and more.
Choose from thousands of standard stamping die components including Punch & Die, Gas Springs, Guide Components, Coil Springs and many more.
Browse our wide variety of mold components including Ejector Pins, Sleeves, Leader Components, Sprue Bushings and many more.
Browse our injection molding components including Heating Items, Couplers, Hoses and more.
[Features]
・ When supplying power to the CC-Link/LT system from an external power supply (arranged by the customer), it can stabilize the power supply to the entire system
・ It depends on the connected model. Maximum of 28.8 V DC
Part Number
Configured Part Number is shown.
CL1PAD1
CL1PAD1 external appearance
CL1PAD1 dimensional drawing, unit: mm
Voltage Input Range | Max. 28.8 V DC (rated voltage 24 V DC) |
---|---|
Max. Rated Current | 5.0 A [Use the system so that the total current consumption of each station does not exceed the maximum rated current when power is supplied (except immediately after the power is turned on).] |
External Connection Method | · Power supply to power supply adapter: terminal block, 3 points (M3 screw) · Power supply part to communication part and CC-Link/LT system: dedicated CC-Link/LT connector (4 pins) × 2 |
Mass | 0.26 kg |
Ambient Temperature | 0 to 55°C - When Operating, -25 to 70°C - When Saving | ||
---|---|---|---|
Relative Humidity | 5 to 95% RH (No Condensation) - When Operating / When Saving | ||
Vibration Resistance | Under Intermittent Vibration | Frequency: 10 To 57 Hz | Single amplitude: 0.075 mm 10 times in each direction of X, Y and Z (total 80 minutes each) |
Frequency: 57 To 150 Hz | Acceleration: 9.8 m/s2 10 times in each direction of X, Y and Z (total 80 minutes each) | ||
Under Continuous Vibration | Frequency: 10 To 57 Hz | Single amplitude: 0.035 mm 10 times in each direction of X, Y and Z (total 80 minutes each) | |
Frequency: 57 To 150 Hz | Acceleration: 4.9 m/s2 10 times in each direction of X, Y and Z (total 80 minutes each) | ||
Impact Resistance | 147 m/s2, 3 times in each direction of X, Y and Z | ||
Insulation Resistance | Between all external terminals at once and the earth terminal: 10 MΩ at 500 V DC on an insulation resistance meter | ||
Operating Atmosphere | There shall be no corrosion gas or flammable gas and not much conductive dust. | ||
Altitude Of Use | 2,000 m or lower Cannot be used in environments pressurized higher than the atmospheric pressure. Doing so may cause failures. | ||
Installation Location | Inside the control panel | ||
Overvoltage Category | II or lower Indicates the assumed wiring part to which the applicable equipment is connected between the public network and the mechanical system in plant. Category II applies to the equipment to which power is supplied from a fixed facility. The surge withstand voltage for equipment of up to 300 V in rating is 2,500 V. | ||
Pollution Degree | 2 or lower Index to indicate the degree of conductive material generation in the use environment. Pollution degree 2 indicates that only non-conductive contaminants will generate. However, temporary conduction may still occur in the environment due to accidental condensation. |
Part Number |
---|
CL1PAD1 |
Part Number | Standard Unit Price | Minimum order quantity | Volume Discount | Days to Ship |
---|---|---|---|---|
SGD 153.40 | 1 Piece(s) | Quote |
Loading...
Rated Input Voltage | DC24V | Maximum Output Voltage/ Current | DC24V· 5A | Note | CL1PAD1 CC-Link/LT Power Supply Adapter (5A) - Compatible Standards: UL/cUL CE (EMC) |
---|
Please check the type/dimensions/specifications of the part CL1PAD1 in the CC-Link/LT Power Adapter series.