SPD for Telephone Line SL-TJ Series (Part Numbers)

SPD for Telephone Line SL-TJ Series

Lightning arrester that supports Category C2/D1 (JIS C5381-21) and protects the telephone line from lightning surges.
[Features]
・ Supports IEC Categories C2 and D1
・ Impulse durability C2: 8/20 μs 10 kA, D1:10/350 μs 5 kA (C2: Positive/negative, 5 times each, 10 times in total, D1: Positive/negative 1 time each, 2 times in total)
・ DIN rail compatible
・ Plug-in type (Easy to check and replace)
[Applications]
・ Protect your telephone line from lightning surges

PDF

Japanese Only

Part Number

Configured Part Number is shown.

SL-T170J

 
Part Number
SL-T170J
Part NumberStandard Unit PriceMinimum order quantityVolume DiscountDays to Ship

SGD 182.42

1 Piece(s) 4 Day(s) or more

Loading...

  1. 1

Basic Information

Application Power line Type Single pole type Mounting Method Clamp type
Class, category IEC category C2 / IEC category D1 Dimension vertical(mm) 98 Dimension width(mm) 10.8
Dimension depth(mm) 72.5 Maximum Continuous Operational Voltage DC170V Impulse resistance (8/20 μs) 10kA
Impulse resistance (10/350 μs) 5kA Voltage protection level Line 400V/Ground 500V

Please check the type/dimensions/specifications of the part SL-T170J in the SPD for Telephone Line SL-TJ Series series.

Tech Support

Factory Automation, Electronics, Tools, & MRO (Maintenance, Repair and Operations)
Tel:(65) 6733 7211 / FAX:(65) 6733 0211
9:00am - 6:00pm (Monday - Friday)