(!)Due to Microsoft's end of support for Internet Explorer 11 on 15/06/2022, this site does not support the recommended environment.
Instead, please kindly use other browsers like Google Chrome, Microsoft Edge or Mozilla Firefox.

  • Scheduled Maintenance Notice: This site will be unavailable due to scheduled maintenance from 9:00 24/11/2024 to 7:00 (SGT) 25/11/2024. We apologize for the inconvenience.
  • Notice of End of Sales for Economy Series Pneumatic Equipment Category. More information.

Membrane Air Dryer Single Type Clean Series 10-IDG Series (10-IDG60H-04B)

Membrane Air Dryer Single Type Clean Series 10-IDG Series 10-IDG60H-04B

[10-Series, Clean Series]
・ Suitable for clean environment
· It prevents dust generation in the cleanroom

(i)Caution

  • Refer to the manufacturer's catalog for specification and material details.
  • The product images are representative only. Please refer to the manufacturer's catalog for shape details.

PDF

Japanese Only

Part Number

Configured Part Number is shown.

10-IDG60H-04B

Drawing

10-IDG3, 5/10-IDG3H, 5H

Membrane air dryer, single unit type, clean series, 10-IDG series, drawing 1

10-IDG10, 10H

Membrane air dryer, single unit type, clean series, 10-IDG series, drawing 2

10-IDG20, 20H

Membrane air dryer, single unit type, clean series, 10-IDG series, drawing 3

Product Specifications

Part number display method

Membrane air dryer, single unit type, clean series, 10-IDG series, part number display method

Standard specifications (Single unit type)

■Standard dew point: -20°C

Part numberStandard dew point -20°C
10-IDG310-IDG510-IDG1010-IDG2010-IDG6010-IDG7510-IDG100
Range of operating conditionsOperating fluid ^*1)Compressed Air
Inlet air pressure (MPa)0.3 to 0.850.3 to 1.0
Inlet air temperature °C-5 to +55 (No freezing)-5 to +50 (no freezing)
Ambient temperature °C-5 to +55 (No freezing)-5 to +50 (no freezing)
Standard performanceOutlet air atmospheric pressure dew point °C-20
Standard performance conditionsInlet air flow rate L/min (ANR)^*2)31621252507259001,190
Outlet air flow rate L/min (ANR)25501002006007501,000
Purge air flow rate L/min (ANR)^*3)6122550125150190
Inlet air pressure (MPa)0.7
Inlet air temperature °C25
Inlet air saturation temperature °C25
Ambient temperature °C25
Dew point indicator purge air flow rate1 L/min (ANR) (at inlet air pressure 0.7 MPa)
Pipe connection diameter1/8·1/41/4·3/83/8·1/21/2
Weight (kg) (with bracket)0.3 (0.36)0.5 (0.58)0.78 (0.88)1.67 (1.82)1.67 (1.82)1.72 (1.87)
Cleanliness class (ISO Class)Class 3

*1) There is no inflow of water droplets.
*2: ANR is the value at 20°C, atmospheric pressure and relative humidity 65%.
*3) Includes 1 L/min (ANR) of purge air flow rate (at 0.7 MPa inlet air pressure) for the dew point indicator. (Excluding 10-IDG3 and 10-IDG5)

■Standard dew point: -15°C / H type

Part numberStandard dew point -15°C
10-IDG3H10-IDG5H10-IDG10H10-IDG20H10-IDG60H10-IDG75H10-IDG100H
Range of operating conditionsOperating fluid ^*1)Compressed Air
Inlet air pressure (MPa)0.3 to 0.850.3 to 1.0
Inlet air temperature °C-5 to +55 (No freezing)-5 to +50 (no freezing)
Ambient temperature °C-5 to +55 (No freezing)-5 to +50 (no freezing)
Standard performanceOutlet air atmospheric pressure dew point °C-15
Standard performance conditionsInlet air flow rate L/min (ANR)^*2)28561112226658301,110
Outlet air flow rate L/min (ANR)25501002006007501,000
Purge air flow rate L/min (ANR)^*3)3611226580110
Inlet air pressure (MPa)0.7
Inlet air temperature °C25
Inlet air saturation temperature °C25
Ambient temperature °C25
Dew point indicator purge air flow rate1 L/min (ANR) (at inlet air pressure 0.7 MPa)
Pipe connection diameter1/8·1/41/4·3/83/8·1/21/2
Weight (kg) (with bracket)0.3 (0.36)0.5 (0.58)0.78 (0.88)1.67 (1.82)1.67 (1.82)1.72 (1.87)
Cleanliness class (ISO Class)Class 3

*1) There is no inflow of water droplets.
*2: ANR is the value at 20°C, atmospheric pressure and relative humidity 65%.
*3) Includes 1 L/min (ANR) of purge air flow rate (at 0.7 MPa inlet air pressure) for the dew point indicator. (Excluding 10-IDG3H and 10-IDG5H)

Part Number
10-IDG60H-04B
Part NumberStandard Unit PriceMinimum order quantityVolume DiscountDays to ShipType Air Inlet Flow
(l/min)
Outlet Open Air Pressure Dew-point
(℃)
Supply Side, Connection Type Supply Side, Plumbing Thread Nominal Control Side, Connection Type Control Side, Plumbing Thread Nominal Standard size Accessory Flow Direction Dew Point Checker

-

1 Piece(s) Quote Dryer600-15[Rc(R)] Rc1/2[Rc(R)] Rc1/260With BracketFlow direction (Left to Right)No (Standard)

Loading...

  1. 1

Basic Information

Method Hollow Fiber Type Shape Standard Inlet Air Temperature(℃) 25

Please check the type/dimensions/specifications of the part 10-IDG60H-04B in the Membrane Air Dryer Single Type Clean Series 10-IDG Series series.

Similar Part Numbers

Part Number
10-IDG10-03
10-IDG10-03B
10-IDG10-03B-R
10-IDG60L-03
10-IDG60L-03B
10-IDG60L-04
Part NumberStandard Unit PriceMinimum order quantityVolume DiscountDays to ShipType Air Inlet Flow
(l/min)
Outlet Open Air Pressure Dew-point
(℃)
Supply Side, Connection Type Supply Side, Plumbing Thread Nominal Control Side, Connection Type Control Side, Plumbing Thread Nominal Standard size Accessory Flow Direction Dew Point Checker

-

1 Piece(s) Quote Dryer100-20[Rc(R)] Rc3/8[Rc(R)] Rc3/810No (Standard)Flow direction (Left to Right)No (Standard)

-

1 Piece(s) Quote Dryer100-20[Rc(R)] Rc3/8[Rc(R)] Rc3/810With BracketFlow direction (Left to Right)No (Standard)

-

1 Piece(s) Quote Dryer100-20[Rc(R)] Rc3/8[Rc(R)] Rc3/810With BracketFlow direction (Right to Left)No (Standard)

SGD 3,212.07

1 Piece(s) 32 Day(s) -600-40[Rc(R)] Rc3/8[Rc(R)] Rc3/8-No (Standard)Flow direction (Left to Right)No (Standard)

-

1 Piece(s) Quote -600-40[Rc(R)] Rc3/8[Rc(R)] Rc3/8-With BracketFlow direction (Left to Right)No (Standard)

-

1 Piece(s) Quote Dryer600-40[Rc(R)] Rc1/2[Rc(R)] Rc1/260No (Standard)Flow direction (Left to Right)No (Standard)