Circulating Fluid Temperature Controller, Thermo-Chiller, Inverter Type, Air-Cooled, 200 V / 400 V Specification, HRSH090 Series (HRSH090-A-20)

Circulating Fluid Temperature Controller, Thermo-Chiller, Inverter Type, Air-Cooled, 200 V / 400 V Specification, HRSH090 Series HRSH090-A-20

Outstanding energy saving effect with triple inverter.
[Features]
・ Compact and space-saving
・ Quiet design
・ Compatible with power supplies in EU, Asia, Oceania, North America, Central and South America
・ Power reduction effect by inverter pump
・ The pressure of the circulating fluid can be regulated
・ Circulating fluid can be heated without a heater

(i)Caution

  • Refer to the manufacturer's catalog for specification and material details.
  • The product images are representative only. Please refer to the manufacturer's catalog for shape details.
  • CAD data is not available for some model numbers.

PDF

Japanese Only

Part Number

Configured Part Number is shown.

HRSH090-A-20

Part Number
HRSH090-A-20
Part NumberStandard Unit PriceMinimum order quantityVolume DiscountDays to ShipType Cooling Method Piping thread type Optional specifications Power Supply Specification

SGD 29,010.57

1 Piece(s) 32 Day(s) Thermo-ChillerAir-CoolingRcNoneThree-phase 200 V AC (50 Hz), Three-phase 200 to 230 V AC (60 Hz)

Loading...

  1. 1

Basic Information

Cooling capacity 9.5 kW Cooling method Air-cooled refrigeration type

Please check the type/dimensions/specifications of the part HRSH090-A-20 in the Circulating Fluid Temperature Controller, Thermo-Chiller, Inverter Type, Air-Cooled, 200 V / 400 V Specification, HRSH090 Series series.

Similar Part Numbers

Part Number
HRSH090-A-20-B
HRSH090-A-20-BJ
HRSH090-A-20-BJM
HRSH090-A-20-BJW
HRSH090-A-20-BM
HRSH090-A-20-BW
Part NumberStandard Unit PriceMinimum order quantityVolume DiscountDays to ShipType Cooling Method Piping thread type Optional specifications Power Supply Specification

SGD 31,198.30

1 Piece(s) 32 Day(s) Thermo-ChillerAir-CoolingRcWith earth leakage circuit breakerThree-phase 200 V AC (50 Hz), Three-phase 200 to 230 V AC (60 Hz)

-

1 Piece(s) Quote --RcWith earth leakage circuit breaker, with automatic water supplyThree-phase 200 V AC (50 Hz), Three-phase 200 to 230 V AC (60 Hz)

-

1 Piece(s) Quote --RcWith earth leakage circuit breaker,with automatic water supply, for deionized water (pure water) pipingThree-phase 200 V AC (50 Hz), Three-phase 200 to 230 V AC (60 Hz)

-

1 Piece(s) Quote --RcWith earth leakage circuit breaker / with automatic water supply / fixed SI unitThree-phase 200 V AC (50 Hz), Three-phase 200 to 230 V AC (60 Hz)

-

1 Piece(s) Quote --RcWith earth leakage circuit breaker, for deionized water (pure water) pipingThree-phase 200 V AC (50 Hz), Three-phase 200 to 230 V AC (60 Hz)

-

1 Piece(s) Quote --RcWith earth leakage circuit breaker, SI unit onlyThree-phase 200 V AC (50 Hz), Three-phase 200 to 230 V AC (60 Hz)