2-Port Solenoid Valve for Dust Collector, VXF2 Series (Part Numbers)

2-Port Solenoid Valve for Dust Collector, VXF2 Series

It is a 2 port solenoid valve for dust collector VXF2 Series.
[Features]
・ Suitable for high temperature and large diameter
・ It can be mounted according to piping conditions (Flange Type)
・ It contributes to reduction of piping labor-hours, because there is no need to process orifice on the secondary (Flange body type)
・ Protective structure IP65 (Electrical entry flat terminal type terminal section is IP40)
· Improved armature durability
· UL94V-0 conforming flame resistance
・ Built-in full-wave rectifier type (AC specification)

(i)Caution

  • Refer to the manufacturer's catalog for specification and material details.
  • The product images are representative only. Please refer to the manufacturer's catalog for shape details.
  • CAD data is not available for some model numbers.

PDF

Japanese Only

Product Specifications

2-Port Solenoid Valve for Dust Collector VXF2 Series product specifications 01

A: Straight pipe type

Product specifications 02 of 2-Port Solenoid Valve for Dust Collector VXF2 Series

B: Flange type

Product specifications 03 of 2-Port Solenoid Valve for Dust Collector VXF2 Series

C: Flange body type I
(Orifice body assembly type)

Product specifications 04 of 2-Port Solenoid Valve for Dust Collector VXF2 Series

D: Flange body type II
(Orifice body co-tightening type)

Product specifications 05 of 2-Port Solenoid Valve for Dust Collector VXF2 Series
Part Number
VXF23AAZ2CA
VXF23AAZ2D
VXF23AAZ2DB
VXF23AAZ2E
VXF23AAZ2EA
VXF23AAZ2G
VXF23AAZ2GA
VXF23AAZ2H
VXF23AAZ2L
VXF23AAZ2M
VXF23AAZ2MB
VXF23AAZ2R
VXF23AAZ2S
VXF23AAZ2V
VXF23AAZ2VA
VXF23AAZ3AA
VXF23AAZ3EA
VXF23AAZ3V
VXF23ABA
VXF23ABAA
VXF23ABAB
VXF23ABB
VXF23ABC
VXF23ABD
VXF23ABE
VXF23ABF
VXF23ABG
VXF23ABGA
VXF23ABGB
VXF23ABH
VXF23ABHB
VXF23ABJ
VXF23ABJB
VXF23ABK
VXF23ABL
VXF23ABLA
VXF23ABM
VXF23ABN
VXF23ABP
VXF23ABQ
VXF23ABR
VXF23ABS
VXF23ABT
VXF23ABU
VXF23ABV
VXF23ABZ1B
VXF23ABZ1E
VXF23ABZ1G
VXF23ABZ1GA
VXF23ABZ1L
VXF23ABZ1Q
VXF23ABZ2A
VXF23ABZ2AA
VXF23ABZ2C
VXF23ABZ2CA
VXF23ABZ2D
VXF23ABZ2E
VXF23ABZ2G
VXF23ABZ2K
VXF23ABZ2L
VXF23ABZ2MB
VXF23ABZ2N
VXF23ABZ2R
VXF23ACB
VXF23ACCA
VXF23ACD
VXF23ACEA
VXF23ACN
VXF23ACQ
VXF23ACRA
VXF23ACUB
VXF23ACV
VXF23ACZ1BA
VXF23ACZ2L
VXF23ADB
VXF23ADCB
VXF23ADD
VXF23ADN
VXF23ADP
VXF23ADQ
VXF23ADZ1B
VXF23ADZ1L
VXF23ADZ1WA
VXF23ADZ2L
VXF23ADZ2M
VXF23ADZ2N
VXF24AAA
VXF24AAAA
VXF24AAB
VXF24AAC
Part NumberStandard Unit PriceMinimum order quantityVolume DiscountDays to ShipConnection Type Plumbing Thread Nominal Tube Flange Nominal Orifice Dia.
(Ø)
Operating Temperature Range
(°C)
Voltage Option Body material Lead wire electrical entry Piping Specifications Piping Connection Port Diameter Pipe connection thread of piping options

-

1 Piece(s) Quote G1 1/2-44-10~60110 V ACWithout silencerPOMDIN terminal (With surge voltage suppressor)Straight pipe typeWith light40 AYes

-

1 Piece(s) Quote [Rc (R)] Rc (R)1 1/2-44-10~60200 V ACWithout silencerPOMDIN terminal (With surge voltage suppressor)Straight pipe typeWith light40 ANone

-

1 Piece(s) Quote NPT1 1/2-44-10~60200 V ACWithout silencerPOMDIN terminal (With surge voltage suppressor)Straight pipe typeWith light40 AYes

-

1 Piece(s) Quote [Rc (R)] Rc (R)1 1/2-44-10~60230 V DCWithout silencerPOMDIN terminal (With surge voltage suppressor)Straight pipe typeWith light40 ANone

-

1 Piece(s) Quote G1 1/2-44-10~60230 V DCWithout silencerPOMDIN terminal (With surge voltage suppressor)Straight pipe typeWith light40 AYes

SGD 260.87

1 Piece(s) 32 Day(s) [Rc (R)] Rc (R)1 1/2-44-10~60220 V ACWithout silencerPOMDIN terminal (With surge voltage suppressor)Straight pipe typeWith light40 ANone

-

1 Piece(s) Quote G1 1/2-44-10~60220 V ACWithout silencerPOMDIN terminal (With surge voltage suppressor)Straight pipe typeWith light40 AYes

-

1 Piece(s) Quote [Rc (R)] Rc (R)1 1/2-44-10~60240 V ACWithout silencerPOMDIN terminal (With surge voltage suppressor)Straight pipe typeWith light40 ANone

-

1 Piece(s) Quote [Rc (R)] Rc (R)1 1/2-44-10~60100 V ACWithout silencerPOMConduit terminal (With surge voltage suppressor)Straight pipe typeWith light40 ANone

-

1 Piece(s) Quote [Rc (R)] Rc (R)1 1/2-44-10~60110 V ACWithout silencerPOMConduit terminal (With surge voltage suppressor)Straight pipe typeWith light40 ANone

-

1 Piece(s) Quote NPT1 1/2-44-10~60110 V ACWithout silencerPOMConduit terminal (With surge voltage suppressor)Straight pipe typeWith light40 AYes

SGD 256.55

1 Piece(s) 32 Day(s) [Rc (R)] Rc (R)1 1/2-44-10~60220 V ACWithout silencerPOMConduit terminal (With surge voltage suppressor)Straight pipe typeWith light40 ANone

-

1 Piece(s) Quote [Rc (R)] Rc (R)1 1/2-44-10~60240 V ACWithout silencerPOMConduit terminal (With surge voltage suppressor)Straight pipe typeWith light40 ANone

-

1 Piece(s) Quote [Rc (R)] Rc (R)1 1/2-44-10~6024 V DCWithout silencerPOMDIN terminal (With surge voltage suppressor)Straight pipe typeWith light40 ANone

-

1 Piece(s) Quote G1 1/2-44-10~6024 V DCWithout silencerPOMDIN terminal (With surge voltage suppressor)Straight pipe typeWith light40 AYes

-

1 Piece(s) Quote G1 1/2-44-10~60-Without silencerPOMDIN terminal (With surge voltage suppressor)Straight pipe typeWithout DIN connector40 AYes

-

1 Piece(s) Quote G1 1/2-44-10~60230 V DCWithout silencerPOMDIN terminal (With surge voltage suppressor)Straight pipe typeWithout DIN connector40 AYes

-

1 Piece(s) Quote [Rc (R)] Rc (R)1 1/2-44-10~6024 V DCWithout silencerPOMDIN terminal (With surge voltage suppressor)Straight pipe typeWithout DIN connector40 ANone

SGD 239.75

1 Piece(s) 32 Day(s) [Rc (R)] Rc (R)1 1/2-44-10~60-With silencerPOMGrommetStraight pipe typeStandard40 ANone

-

1 Piece(s) Quote G1 1/2-44-10~60-With silencerPOMGrommetStraight pipe typeStandard40 AYes

-

1 Piece(s) Quote NPT1 1/2-44-10~60-With silencerPOMGrommetStraight pipe typeStandard40 AYes

SGD 239.75

1 Piece(s) 32 Day(s) [Rc (R)] Rc (R)1 1/2-44-10~60100 V ACWith silencerPOMGrommet (With surge voltage suppressor)Straight pipe typeStandard40 ANone

-

1 Piece(s) Quote [Rc (R)] Rc (R)1 1/2-44-10~60110 V ACWith silencerPOMGrommet (With surge voltage suppressor)Straight pipe typeStandard40 ANone

SGD 239.75

1 Piece(s) 32 Day(s) [Rc (R)] Rc (R)1 1/2-44-10~60200 V ACWith silencerPOMGrommet (With surge voltage suppressor)Straight pipe typeStandard40 ANone

SGD 239.75

1 Piece(s) 32 Day(s) [Rc (R)] Rc (R)1 1/2-44-10~60230 V DCWith silencerPOMGrommet (With surge voltage suppressor)Straight pipe typeStandard40 ANone

SGD 255.73

1 Piece(s) 32 Day(s) [Rc (R)] Rc (R)1 1/2-44-10~60-With silencerPOMGrommet (With surge voltage suppressor)Straight pipe typeStandard40 ANone

SGD 257.13

1 Piece(s) 32 Day(s) [Rc (R)] Rc (R)1 1/2-44-10~60-With silencerPOMDIN terminal (With surge voltage suppressor)Straight pipe typeStandard40 ANone

-

1 Piece(s) Quote G1 1/2-44-10~60-With silencerPOMDIN terminal (With surge voltage suppressor)Straight pipe typeStandard40 AYes

-

1 Piece(s) Quote NPT1 1/2-44-10~60-With silencerPOMDIN terminal (With surge voltage suppressor)Straight pipe typeStandard40 AYes

SGD 257.13

1 Piece(s) 32 Day(s) [Rc (R)] Rc (R)1 1/2-44-10~60100 V ACWith silencerPOMDIN terminal (With surge voltage suppressor)Straight pipe typeStandard40 ANone

-

1 Piece(s) Quote NPT1 1/2-44-10~60100 V ACWith silencerPOMDIN terminal (With surge voltage suppressor)Straight pipe typeStandard40 AYes

SGD 257.13

1 Piece(s) 32 Day(s) [Rc (R)] Rc (R)1 1/2-44-10~60110 V ACWith silencerPOMDIN terminal (With surge voltage suppressor)Straight pipe typeStandard40 ANone

-

1 Piece(s) Quote NPT1 1/2-44-10~60110 V ACWith silencerPOMDIN terminal (With surge voltage suppressor)Straight pipe typeStandard40 AYes

SGD 257.13

1 Piece(s) 32 Day(s) [Rc (R)] Rc (R)1 1/2-44-10~60200 V ACWith silencerPOMDIN terminal (With surge voltage suppressor)Straight pipe typeStandard40 ANone

SGD 257.13

1 Piece(s) 32 Day(s) [Rc (R)] Rc (R)1 1/2-44-10~60230 V DCWith silencerPOMDIN terminal (With surge voltage suppressor)Straight pipe typeStandard40 ANone

-

1 Piece(s) Quote G1 1/2-44-10~60230 V DCWith silencerPOMDIN terminal (With surge voltage suppressor)Straight pipe typeStandard40 AYes

SGD 260.05

1 Piece(s) 32 Day(s) [Rc (R)] Rc (R)1 1/2-44-10~60-With silencerPOMConduit terminal (With surge voltage suppressor)Straight pipe typeStandard40 ANone

SGD 260.05

1 Piece(s) 32 Day(s) [Rc (R)] Rc (R)1 1/2-44-10~60100 V ACWith silencerPOMConduit terminal (With surge voltage suppressor)Straight pipe typeStandard40 ANone

SGD 260.05

1 Piece(s) 32 Day(s) [Rc (R)] Rc (R)1 1/2-44-10~60110 V ACWith silencerPOMConduit terminal (With surge voltage suppressor)Straight pipe typeStandard40 ANone

SGD 260.05

1 Piece(s) 32 Day(s) [Rc (R)] Rc (R)1 1/2-44-10~60200 V ACWith silencerPOMConduit terminal (With surge voltage suppressor)Straight pipe typeStandard40 ANone

-

1 Piece(s) Quote [Rc (R)] Rc (R)1 1/2-44-10~60230 V DCWith silencerPOMConduit terminal (With surge voltage suppressor)Straight pipe typeStandard40 ANone

-

1 Piece(s) Quote [Rc (R)] Rc (R)1 1/2-44-10~60-With silencerPOMConduit (With surge voltage suppressor)Straight pipe typeStandard40 ANone

SGD 246.98

1 Piece(s) 32 Day(s) [Rc (R)] Rc (R)1 1/2-44-10~60100 V ACWith silencerPOMConduit (With surge voltage suppressor)Straight pipe typeStandard40 ANone

SGD 246.98

1 Piece(s) 32 Day(s) [Rc (R)] Rc (R)1 1/2-44-10~60110 V ACWith silencerPOMConduit (With surge voltage suppressor)Straight pipe typeStandard40 ANone

SGD 246.98

1 Piece(s) 32 Day(s) [Rc (R)] Rc (R)1 1/2-44-10~60200 V ACWith silencerPOMConduit (With surge voltage suppressor)Straight pipe typeStandard40 ANone

SGD 239.75

1 Piece(s) 32 Day(s) [Rc (R)] Rc (R)1 1/2-44-10~60220 V ACWith silencerPOMGrommet (With surge voltage suppressor)Straight pipe typeSpecial voltage40 ANone

-

1 Piece(s) Quote [Rc (R)] Rc (R)1 1/2-44-10~6012 V DCWith silencerPOMGrommet (With surge voltage suppressor)Straight pipe typeSpecial voltage40 ANone

SGD 257.13

1 Piece(s) 32 Day(s) [Rc (R)] Rc (R)1 1/2-44-10~60220 V ACWith silencerPOMDIN terminal (With surge voltage suppressor)Straight pipe typeSpecial voltage40 ANone

SGD 264.37

1 Piece(s) 32 Day(s) G1 1/2-44-10~60220 V ACWith silencerPOMDIN terminal (With surge voltage suppressor)Straight pipe typeSpecial voltage40 AYes

SGD 260.05

1 Piece(s) 32 Day(s) [Rc (R)] Rc (R)1 1/2-44-10~60220 V ACWith silencerPOMConduit terminal (With surge voltage suppressor)Straight pipe typeSpecial voltage40 ANone

SGD 246.98

1 Piece(s) 32 Day(s) [Rc (R)] Rc (R)1 1/2-44-10~60220 V ACWith silencerPOMConduit (With surge voltage suppressor)Straight pipe typeSpecial voltage40 ANone

SGD 271.60

1 Piece(s) 32 Day(s) [Rc (R)] Rc (R)1 1/2-44-10~60-With silencerPOMDIN terminal (With surge voltage suppressor)Straight pipe typeWith light40 ANone

-

1 Piece(s) Quote G1 1/2-44-10~60-With silencerPOMDIN terminal (With surge voltage suppressor)Straight pipe typeWith light40 AYes

-

1 Piece(s) Quote [Rc (R)] Rc (R)1 1/2-44-10~60110 V ACWith silencerPOMDIN terminal (With surge voltage suppressor)Straight pipe typeWith light40 ANone

-

1 Piece(s) Quote G1 1/2-44-10~60110 V ACWith silencerPOMDIN terminal (With surge voltage suppressor)Straight pipe typeWith light40 AYes

-

1 Piece(s) Quote [Rc (R)] Rc (R)1 1/2-44-10~60200 V ACWith silencerPOMDIN terminal (With surge voltage suppressor)Straight pipe typeWith light40 ANone

-

1 Piece(s) Quote [Rc (R)] Rc (R)1 1/2-44-10~60230 V DCWith silencerPOMDIN terminal (With surge voltage suppressor)Straight pipe typeWith light40 ANone

SGD 271.60

1 Piece(s) 32 Day(s) [Rc (R)] Rc (R)1 1/2-44-10~60220 V ACWith silencerPOMDIN terminal (With surge voltage suppressor)Straight pipe typeWith light40 ANone

-

1 Piece(s) Quote [Rc (R)] Rc (R)1 1/2-44-10~60-With silencerPOMConduit terminal (With surge voltage suppressor)Straight pipe typeWith light40 ANone

-

1 Piece(s) Quote [Rc (R)] Rc (R)1 1/2-44-10~60100 V ACWith silencerPOMConduit terminal (With surge voltage suppressor)Straight pipe typeWith light40 ANone

-

1 Piece(s) Quote NPT1 1/2-44-10~60110 V ACWith silencerPOMConduit terminal (With surge voltage suppressor)Straight pipe typeWith light40 AYes

-

1 Piece(s) Quote [Rc (R)] Rc (R)1 1/2-44-10~60200 V ACWith silencerPOMConduit terminal (With surge voltage suppressor)Straight pipe typeWith light40 ANone

SGD 267.28

1 Piece(s) 32 Day(s) [Rc (R)] Rc (R)1 1/2-44-10~60220 V ACWith silencerPOMConduit terminal (With surge voltage suppressor)Straight pipe typeWith light40 ANone

-

1 Piece(s) Quote [Rc (R)] Rc (R)1 1/2-44-10~100100 V ACWithout silencerPTEFGrommet (With surge voltage suppressor)Straight pipe typeStandard40 ANone

-

1 Piece(s) Quote G1 1/2-44-10~100110 V ACWithout silencerPTEFGrommet (With surge voltage suppressor)Straight pipe typeStandard40 AYes

-

1 Piece(s) Quote [Rc (R)] Rc (R)1 1/2-44-10~100200 V ACWithout silencerPTEFGrommet (With surge voltage suppressor)Straight pipe typeStandard40 ANone

-

1 Piece(s) Quote G1 1/2-44-10~100230 V DCWithout silencerPTEFGrommet (With surge voltage suppressor)Straight pipe typeStandard40 AYes

-

1 Piece(s) Quote [Rc (R)] Rc (R)1 1/2-44-10~100100 V ACWithout silencerPTEFConduit terminal (With surge voltage suppressor)Straight pipe typeStandard40 ANone

-

1 Piece(s) Quote [Rc (R)] Rc (R)1 1/2-44-10~100200 V ACWithout silencerPTEFConduit terminal (With surge voltage suppressor)Straight pipe typeStandard40 ANone

-

1 Piece(s) Quote G1 1/2-44-10~100230 V DCWithout silencerPTEFConduit terminal (With surge voltage suppressor)Straight pipe typeStandard40 AYes

-

1 Piece(s) Quote NPT1 1/2-44-10~100110 V ACWithout silencerPTEFConduit (With surge voltage suppressor)Straight pipe typeStandard40 AYes

-

1 Piece(s) Quote [Rc (R)] Rc (R)1 1/2-44-10~100200 V ACWithout silencerPTEFConduit (With surge voltage suppressor)Straight pipe typeStandard40 ANone

-

1 Piece(s) Quote G1 1/2-44-10~100220 V ACWithout silencerPTEFGrommet (With surge voltage suppressor)Straight pipe typeSpecial voltage40 AYes

-

1 Piece(s) Quote [Rc (R)] Rc (R)1 1/2-44-10~100100 V ACWithout silencerPTEFConduit terminal (With surge voltage suppressor)Straight pipe typeWith light40 ANone

-

1 Piece(s) Quote [Rc (R)] Rc (R)1 1/2-44-10~100100 V ACWith silencerPTEFGrommet (With surge voltage suppressor)Straight pipe typeStandard40 ANone

-

1 Piece(s) Quote NPT1 1/2-44-10~100110 V ACWith silencerPTEFGrommet (With surge voltage suppressor)Straight pipe typeStandard40 AYes

-

1 Piece(s) Quote [Rc (R)] Rc (R)1 1/2-44-10~100200 V ACWith silencerPTEFGrommet (With surge voltage suppressor)Straight pipe typeStandard40 ANone

-

1 Piece(s) Quote [Rc (R)] Rc (R)1 1/2-44-10~100100 V ACWith silencerPTEFConduit terminal (With surge voltage suppressor)Straight pipe typeStandard40 ANone

-

1 Piece(s) Quote [Rc (R)] Rc (R)1 1/2-44-10~100110 V ACWith silencerPTEFConduit terminal (With surge voltage suppressor)Straight pipe typeStandard40 ANone

-

1 Piece(s) Quote [Rc (R)] Rc (R)1 1/2-44-10~100200 V ACWith silencerPTEFConduit terminal (With surge voltage suppressor)Straight pipe typeStandard40 ANone

-

1 Piece(s) Quote [Rc (R)] Rc (R)1 1/2-44-10~100220 V ACWith silencerPTEFGrommet (With surge voltage suppressor)Straight pipe typeSpecial voltage40 ANone

-

1 Piece(s) Quote [Rc (R)] Rc (R)1 1/2-44-10~100220 V ACWith silencerPTEFConduit terminal (With surge voltage suppressor)Straight pipe typeSpecial voltage40 ANone

-

1 Piece(s) Quote G1 1/2-44-10~10024 V DCWith silencerPTEFConduit terminal (With surge voltage suppressor)Straight pipe typeSpecial voltage40 AYes

-

1 Piece(s) Quote [Rc (R)] Rc (R)1 1/2-44-10~100100 V ACWith silencerPTEFConduit terminal (With surge voltage suppressor)Straight pipe typeWith light40 ANone

-

1 Piece(s) Quote [Rc (R)] Rc (R)1 1/2-44-10~100110 V ACWith silencerPTEFConduit terminal (With surge voltage suppressor)Straight pipe typeWith light40 ANone

-

1 Piece(s) Quote [Rc (R)] Rc (R)1 1/2-44-10~100200 V ACWith silencerPTEFConduit terminal (With surge voltage suppressor)Straight pipe typeWith light40 ANone

SGD 342.07

1 Piece(s) 32 Day(s) [Rc (R)] Rc (R)2---10~60-Without silencerPOMGrommetStraight pipe typeStandard50 ANone

-

1 Piece(s) Quote G2---10~60-Without silencerPOMGrommetStraight pipe typeStandard50 AYes

-

1 Piece(s) Quote [Rc (R)] Rc (R)2---10~60100 V ACWithout silencerPOMGrommet (With surge voltage suppressor)Straight pipe typeStandard50 ANone

-

1 Piece(s) Quote [Rc (R)] Rc (R)2---10~60110 V ACWithout silencerPOMGrommet (With surge voltage suppressor)Straight pipe typeStandard50 ANone

Loading...

Basic Information

Type Electromagnetic Type Applicable Fluid Air Operating Environment Standard
Switching Type Normally Closed Driving Type Pilot Type

Tech Support