Air Cooled Aftercooler HAA Series (HAA7-062D)

Air Cooled Aftercooler HAA Series HAA7-062D

This air-cooled aftercooler does not require cooling equipment, and maintenance is easy without concerns about water supply cut-off or freezing.
[Features]
· Cools high temperature compressed air from a compressor down to 40°C or less and removes moisture from the air.
· Compact size and light weight.
· Uses minimal floor space.
· Built-in drain separator.
· Dust-protecting filter optional.

(i)Caution

  • ■ SMC Product Line
    Webpages for products currently without individual pages on this site will be released on an ad-hoc basis.

    ■ Products Planned for Online Release
    Air cylinder-related product pages will be released on this site on an ad-hoc basis.
    CQ2/MG types, etc., are already available.
    *Vacuum equipment, FRLs, solenoid valves, etc., will also be released on dedicated pages on this site on an ad-hoc basis.
    *The information above is correct as of December 2018.
  • See catalog for specification details.
  • Product images may be representative images. Refer to the manufacturer's catalog for shape details.

PDF

Air Cooled Aftercooler HAA Series Features

HAA15 external appearance

HAA15 external appearance

HAA7 external appearance

HAA7 external appearance

Working Principle

Working Principle

Specifications

ModelHAA7HAA15HAA22HAA37
Rated conditionsAir flow capacity L/min (ANR)*11,0002,2003,3005,700
Inlet air temperature (°C)70
Inlet air pressure (MPa)0.7
Ambient temperature (°C)32
Outlet air temperature (°C)40
Operating rangeApplicable fluidCompressed Air
Inlet air temperature (°C)5 to 100
Inlet air pressure (MPa)0.05 to 1.0 (With auto drain: 0.15 to 1.0)0.05 to 0.97 (With auto drain: 0.15 to 0.97)
Ambient temperature (°C)2 to 50
Installation locationIndoors
Electric specificationsPower supplySingle-phase
100 V AC (50/60 Hz)
Single-phase
200 V AC (50/60 Hz)
Single-phase
100 V AC (50/60 Hz)
Three-phase
200 V AC (50/60 Hz)
Three-phase
200 V AC (50/60 Hz)
Three-phase
200 V AC (50/60 Hz)
Power consumption (W)50 Hz5558555090204
60 Hz58656560130244
Current (A)50 Hz0.80.430.80.40.42.0
60 Hz0.810.460.90.350.452.0
Proof pressure (MPa)1.5
Cooling fan diameter (mm)255300400350 × 2 pcs.
CoolerAluminum plate tube with fins
Port size for inlet/outlet airRp3/4 socket1B union1 1/2 B union
Port size for drain outlet piping
(With auto drain)
Rc 3/8
(Rc 3/8)
Rc 1/2
(Rc 3/8)
Weight (kg)18243655
Coating colorMunsell N-8 (white), Munsell 2.5PB5/8.5 (blue)
Applicable compressor (kW)*27.5152237
Standard equipmentThermometer for outlet air temperature (1 pc.)-
Accessories*3Drain valve (1 pc.)3/8B1/2B
Union (2 pcs.)-1B1 1/2 B

*1: ANR is the value at 20°C, atmospheric pressure and relative humidity 65%.
*2: The applicable compressor is based on the discharge rate and discharge temperature (70°C) of a screw-type compressor.
*3: Accessories should be mounted by the user.

Dimensions

 

(Unit: mm)

 

Dimensions: HAA7

Dimensions: HAA7

 

(Unit: mm)

 

HAA15-22 dimensions

HAA15-22 dimensions

 

(Unit: mm)

 

HAA37 dimensions

HAA37 dimensions

 

 

(Unit: mm)

 

ModelPiping connection port diameterABCDEFGHJKLMNPQRS
HAA151B union4603943370594854283201501503207058200480220225
HAA221 1/2B union5884845270605805053331501504009465200610220238

How to Calculate Outlet Air Temperature

The outlet air temperature can be calculated by the inlet air temperature, ambient temperature and air flow capacity using the following procedure.

(Example) Inlet air temperature: 100°C, Ambient temperature: 20°C, Air flow capacity: 2,000 L/min (ANR), Air pressure:
0.7 MPa, Model: HAA22-14

Correction factor by ambient temperature

Correction factor by ambient temperature

  1. 1. Use an outlet air temperature of 38.5°C from the Outlet Air Temperature table. In this case, use correction factor line A.
  2. 2. Next, use the correction factor by ambient temperature chart to obtain a correction factor of 1.35 at the ambient temperature of 20°C on line A.
  3. 3. Divide 38.5°C (from step 1) by 1.35 (from step 2) to obtain the outlet air temperature. Outlet air temperature = 38.5 ÷ 1.35 = 28.5°C

Outlet Air Temperature

ModelCorrection factor lineAir flow (L/min [ANR])Inlet air temperature
50°C70°C100°C
HAA7(A)50034.53535.5
(B)1,000384042.5
(C)1,500404447.5
HAA15(A)1,0003335.536
(B)2,20036.54042.5
(C)3,000384244
HAA22(A)2,000343738.5
(B)3,300364042.5
(C)4,0003741.545
HAA37(A)4,000343839
(B)5,700354043
(C)7,000364245

Conditions:

  • Air pressure 0.7 MPa, ambient temperature 32°C.
  • An inlet air temperature of 50°C is saturated air. At 70°C or more, it is humid air with a dew point of 67°C.

Precautions

Caution on Design

Caution

  • 1. Do not obstruct the aftercooler's vent inlet and outlet, and be sure to install the aftercooler more than 20 cm away from the walls and other equipment.
  • 2. Install the aftercooler in a location that facilitates maintenance and inspection.
  • 3. Install the aftercooler in a location with minimal vibrations.
  • 4. Because the surrounding temperature increases due to the exhaust heat from the aftercooler, ventilate the area with an exhaust fan, etc.
  • 5. The air-cooled type aftercooler cannot be used in a location where the temperature exceeds 50°C. To use in such a location, use a water-cooled type aftercooler instead.
  • 6. The maximum allowable temperature of the inlet air is 100°C.
    If the inlet air exceeds this temperature, select an appropriate water-cooled type aftercooler.
  • 7. Prevent fins from becoming clogged. Do not use this aftercooler in an area that has viscous dust (electrostatic paint powder, oily particles, etc.). If it must be used under such conditions due to unavoidable circumstances, please contact the manufacturer support center beforehand.

Mounting

Caution

  • 1. Do not interchange the connections to the compressed air inlet and the compressed air outlet. When tightening the air inlet and outlet piping, make sure to use a pipe wrench to hold the inlet and outlet nozzles of the product.
  • 2. Connect a drain pipe because drainage is created when the compressed air is cooled.
  • 3. The drain pipe must have a minimum pipe bore of 10 mm and a maximum length of 5 m (when installing an optional auto-drain).

Maintenance

If the aftercooler is equipped with an auto drain, the following mounting frame is necessary. Mounting frame (Option: Refer to p. 11 Accessories)

If the aftercooler is equipped with an auto drain, the following mounting frame is necessary. Mounting frame (Option: Refer to p. 11 Accessories)

Caution

  • 1. Inspect the cooler at least once a week, and clean it to prevent it from becoming obstructed.
  • 2. Discharge the drainage on a regular basis in accordance with the amount of drainage that is created. (The optional auto drain is recommended for automatic discharge.)
  • *See the manufacturer's catalog for other specifications, etc.
Part Number
HAA7-062D
Part NumberStandard Unit PriceMinimum order quantityVolume DiscountDays to ShipAir compressor size (screw type)
(KW)
Piping connection port diameter Power supply voltage
(V)
Auto drain Filter for dust intrusion prevention Frame Terminal

SGD 2,093.47

1 Piece(s) 32 Day(s) 7.5Rp3/4Single-phase 200With auto drainNoneNoneNone

Loading...

  1. 1

Basic Information

Type After Cooler

Please check the type/dimensions/specifications of the part HAA7-062D in the Air Cooled Aftercooler HAA Series series.

Similar Part Numbers

Part Number
HAA15-101DF
HAA15-101DFS
HAA15-101DFS-T
HAA7-062D-T
HAA7-062DF
HAA7-062DF-T
Part NumberStandard Unit PriceMinimum order quantityVolume DiscountDays to ShipAir compressor size (screw type)
(KW)
Piping connection port diameter Power supply voltage
(V)
Auto drain Filter for dust intrusion prevention Frame Terminal

-

1 Piece(s) Quote 151BSingle-phase 100With auto drainWith dust-protecting filterNoneNone

-

1 Piece(s) Quote 151BSingle-phase 100With auto drainWith dust-protecting filterWith mounting frameNone

-

1 Piece(s) Quote 151BSingle-phase 100With auto drainWith dust-protecting filterWith mounting frameWith terminal

-

1 Piece(s) Quote 7.5Rp3/4Single-phase 200With auto drainNoneNoneWith terminal

-

1 Piece(s) Quote 7.5Rp3/4Single-phase 200With auto drainWith dust-protecting filterNoneNone

-

1 Piece(s) Quote 7.5Rp3/4Single-phase 200With auto drainWith dust-protecting filterNoneWith terminal

Tech Support