Motor Operated Auto Drain ADM200 Series (Part Numbers)

Motor Operated Auto Drain ADM200 Series

Drain that reliably discharges high-viscosity condensate
[Features]
・ It is resistant to dust and high-viscosity condensates, and opens and closes the valve securely to discharge the condensate.
・ Large condensate discharge capacity
・ The discharge port can be enlarged and a large amount of condensate can be discharged with a single operation.
・ Condensate does not remain inside the tank or piping, preventing rust and foreign object generated by drying the condensate from adversely affecting downstream equipment.
・ Low power consumption / 4 W
・ Long piping is also possible for the discharge port.
・ It can be attached directly to the compressor.

(i)Caution

  • See catalog for specification details.
  • Product images may be representative images. Refer to the catalog for details.

PDF

Motor Operated Auto Drain ADM200 Specifications

Mounting example

Mounting example

ModelADM200-□□-□
FluidAir
Maximum operating pressure1.0 MPa
Proof pressure1.5 MPa
Ambient and fluid temperature-5 to +60°C (no freezing)
Operating cycle*1 cycle in 1 minute (Standard)
Operating time2 sec./cycle (Standard)
Power Supply100, 200 V AC 50/60 Hz, other
Power consumption4 W
Connection port sizeIN: 3/8, 1/2 
OUT: 3/8
Weight550 g

*If the operating cycle is 2 times in 1 minute (op. time 2 sec. × 2), the operating time is 4 sec. each minute.

Voltage

  • 100 V AC 50 Hz/60 Hz
  • 200 V AC 50 Hz/60 Hz
  • 240 V AC 50 Hz/60 Hz
  • 110 V AC 50 Hz/60 Hz
  • 220 V AC 50 Hz/60 Hz
  • 24 V DC
  • 12 V DC

Operating Time / Applicable Compressor

  • 2 sec/min. (1 time/min.) / 3.7 to 37 kW
  • 4 sec/min. (2 times/min.) / 37 to 75 kW
  • 6 sec/min. (3 times/min.) / 75 to 110 kW
  • 8 sec/min. (4 times/min.) / 220 to 370 kW

Thread type

  • Rc
  • NPT
  • G

Port size

SymbolINOUT
033/83/8
041/23/8

 

(Unit: mm)

 

ADM200 structural and dimensional drawings

ADM200 structural and dimensional drawings

Component Parts

  1. 1.: Body
  2. 2.: Cap
  • Material: die-cast aluminum
  • Remarks: chromate treatment

Replacement Parts

NumberPart nameMaterialPart number
3Motor-Voltage
D126J45-29 (100 V AC)
D126J45-31 (200 V AC)
D126J45-33 (240 V AC)
D126J45-30 (110 V AC)
D126J45-32 (220 V AC)
812PG-DC24V (24 V DC)
4CamCast steelOperating time
201324 (Nil)
201325 (4)
201326 (6)
201327 (8)
5Valve assemblyBrass, NBR20137-1A
6O-ringNBRKA01323
Part Number
ADM200-N044-4
ADM200-N044-8
ADM200-N045
ADM200-N045-4
ADM200-N045-8
ADM200-N046
ADM200-N046-6
Part NumberStandard Unit PriceMinimum order quantityVolume DiscountDays to ShipPower Supply Voltage Inlet Connection Type Inlet Connection Screw Nominal Outlet Connection Type Max. Operating Pressure
(MPa)
Operating Time/Applicable Compressor

-

1 Piece(s) Quote [AC110V] AC110V 50/60HzNPT[1/2B] 1/2NPT14 sec/min. (2 times/min.) / 37 to 75 kW

-

1 Piece(s) Quote [AC110V] AC110V 50/60HzNPT[1/2B] 1/2NPT18 sec/min. (4 time/min.) / 220 to 370 kW

SGD 236.95

1 Piece(s) 32 Day(s) [AC220V] AC220V 50/60HzNPT[1/2B] 1/2NPT12 sec/min. (1 time/min.) / 3.7 to 37 kW

SGD 236.95

1 Piece(s) 32 Day(s) [AC220V] AC220V 50/60HzNPT[1/2B] 1/2NPT14 sec/min. (2 times/min.) / 37 to 75 kW

SGD 236.95

1 Piece(s) 32 Day(s) [AC220V] AC220V 50/60HzNPT[1/2B] 1/2NPT18 sec/min. (4 time/min.) / 220 to 370 kW

SGD 236.95

1 Piece(s) 32 Day(s) DC24VNPT[1/2B] 1/2NPT12 sec/min. (1 time/min.) / 3.7 to 37 kW

-

1 Piece(s) Quote DC24VNPT[1/2B] 1/2NPT16 sec/min. (3 times/min.) / 75 to 110 kW

Loading...

Basic Information

Type Drain Discharge Apparatus Drain Discharge Automatic ejection Drain Discharge Operating Method Compressor Interlocking when ON / Compressor Interlocking when OFF / Constant Time
Outlet Screw Nominal 3/8